Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 3M™ Novec™ 71DE Engineered Fluid
- Product Code
- 70-2134-0513-0, 98-0211-9219-4, 98-0211-9221-0, 98-0211-9223-6, 98-0212-1172-1, 4010034865, 7100025388, 7100034461, 7100025017, 7100260436
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For Industrial Use Only. See Limitations on Use for supplemental information on intended applications including Medical Device applications.
Uses advised against
Novec™ Engineered Fluids are used in a wide variety of applications including but not limited to precision cleaning of medical devices and as a lubricant deposition solvent for medical devices. When the product is used for applications where the finished device is implanted into the human body, no residual Novec™ solvent may remain on the parts. It is highly recommended that the supporting test results and protocol be cited during FDA registration. 3M Electronics Markets Materials Division (EMMD) will not knowingly sample, support, or sell its products for incorporation in medical and pharmaceutical products and applications in which the 3M product will be temporarily or permanently implanted into humans or animals. The customer is responsible for evaluating and determining that a 3M EMMD product is suitable and appropriate for its particular use and intended application. The conditions of evaluation, selection, and use of a 3M product can vary widely and affect the use and intended application of a 3M product. Because many of these conditions are uniquely within the user's knowledge and control, it is essential that the user evaluate and determine whether the 3M product is suitable and appropriate for a particular use and intended application, and complies with all local applicable laws, regulations, standards, and guidance.
Manufacturers & Suppliers
3M
manufacturer
3M Center, St. Paul, MN 55144-1000, USA
1-888-3M HELPS (1-888-364-3577)
Emergency Contacts
Emergency Contact
1-800-364-3577
24 hours
Emergency Contact
(651) 737-6501
24 hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Composition/information on ingredients
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2-Trans-Dichloroethylene | 156-60-5 | 49 - 51% | No |
| Methyl nonafluoroisobutyl ether | 163702-08-7 | 27.5 - 45% | No |
| Methyl nonafluorobutyl ether | 163702-07-6 | 5 - 22.5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air.
Wash with soap and water.
Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing.
Rinse mouth.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use a fire fighting agent suitable for the surrounding fire.
Exposure to extreme heat can give rise to thermal decomposition. Material displays no closed-cup flash point but may form flammable/explosive vapor air mixture.
Firefighter Protection
When fire fighting conditions are severe and total thermal decomposition of the product is possible, wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep away from sparks, flames, and extreme heat. Evacuate area. Ventilate the area with fresh air. For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.
For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.
Avoid release to the environment.
Mix in sufficient absorbent until it appears dry. Collect as much of the spilled material as possible. Clean up residue with an appropriate solvent selected by a qualified and authorized person.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Contents may be under pressure, open carefully. Do not breathe thermal decomposition products. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not get in eyes, on skin, or on clothing. Keep away from sparks, flames, and extreme heat.
Store in a well-ventilated place. Keep container tightly closed. Store away from heat. Store at temperatures not exceeding 38C/100F.
Store work clothes separately from other clothing, food and tobacco products. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. No smoking: Smoking while using this product can result in contamination of the tobacco and/or smoke and lead to the formation of hazardous decomposition products.
Keep away from sparks, flames, and extreme heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate local exhaust when product is heated. Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment. Provide ventilation adequate to maintain vapor concentration below lower explosive concentration.
Chemical protective gloves are not required under normal use conditions. However, when the product is subjected to extreme heat, HF may be formed. For those cases, neoprene gloves are recommended.
Indirect Vented Goggles
An exposure assessment may be needed to decide if a respirator is required. If a respirator is needed, use respirators as part of a full respiratory protection program. Based on the results of the exposure assessment, select from the following respirator type(s) to reduce inhalation exposure: During heating: Use a positive pressure supplied-air respirator if there is a potential for over exposure from an uncontrolled release, exposure levels are not known, or under any other circumstances where air-purifying respirators may not provide adequate protection. Half facepiece or full facepiece air-purifying respirator suitable for organic vapors. Organic vapor respirators may have short service life. For questions about suitability for a specific application, consult with your respirator manufacturer.
Chemical protective gloves are not required under normal use conditions. However, when the product is subjected to extreme heat, HF may be formed. For those cases, neoprene apron is recommended.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.
Hazardous polymerization will not occur.
Heat, Sparks and/or flames
Strong bases, Strong oxidizing agents
Carbon monoxide, Carbon dioxide, Hydrogen Chloride, Hydrogen Fluoride, Perfluoroisobutylene (PFIB), Toxic Vapor, Gas, Particulate. These occur at elevated temperatures or extreme conditions of heat.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 3M™ Novec™ 71DE Engineered Fluid?
The signal word is warning.
What is the physical form of 3M™ Novec™ 71DE Engineered Fluid?
3M™ Novec™ 71DE Engineered Fluid is a liquid with colorless color. It has slight odor odor.
What is 3M™ Novec™ 71DE Engineered Fluid used for?
For Industrial Use Only. See Limitations on Use for supplemental information on intended applications including Medical Device applications.
What are the hazard statements for 3M™ Novec™ 71DE Engineered Fluid?
This substance has 2 hazard statements:
- H319: Causes eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of 3M™ Novec™ 71DE Engineered Fluid?
The melting point is Not Applicable and the boiling point is 41 °C.