Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Non-Spillable Lead Acid Battery
- Synonyms
- Industrial Battery, Traction Battery, Stationary Battery, Deep Cycle Battery
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
Hawker Powersource
manufacturer
P.O. Box 808, Ooltewah, TN 37363
423-238-0361
Hawker Powersource Canada Corporate Office
manufacturer
3-61 Parr Boulevard, Bolton, Ontario, L7E 4E3
423-238-0361
Emergency Contacts
Hawker Powersource, Inc. Environmental, Health & Safety Dept.
423-238-0361
CHEMTREC
800-424-9300
CHEMTREC
703-527-3877
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS01
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Inorganic lead and electrolyte (sulfuric acid) are the primary components of every battery manufactured by Hawker. Other ingredients may be present dependent upon battery type. Contact your Hawker representative for additional information.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyvinylchloride | 9002-86-2 | --- | No |
| Polycarbonate, Hard Rubber, Polyethylene | 9002-88-4 | --- | No |
| Silicon Dioxide (Gel batteries only) | 7631-86-9 | 1 - 5% | No |
| Sheet Molding Compound (Glass reinforced polyester) | --- | --- | No |
| * Antimony | 7440-36-0 | 2% | No |
| * Arsenic | 7440-38-2 | 0.2% | No |
| * Calcium | 7440-70-2 | 0.04% | No |
| * Tin | 7440-31-5 | 0.2% | No |
| Electrolyte (Sulfuric Acid (H2SO4/H2O)) | 7664-93-9 | 10 - 30% | No |
| Case Material: | --- | 5 - 10% | No |
| Lead | 7439-92-1 | 45 - 60% | No |
| Lead Dioxide | 1309-60-0 | 15 - 25% | No |
| Polypropylene | 9003-07-0 | --- | No |
| Polystyrene | 9003-53-6 | --- | No |
| Styrene Acrylonitrile | 9003-54-7 | --- | No |
| Acrylonitrile Butadiene Styrene | 9003-56-9 | --- | No |
| Styrene Butadiene | 9003-55-8 | --- | No |
Notes
Other ingredients may be present dependent upon battery type. Contact your Hawker representative for additional information.
First Aid Measures
Emergency procedures for chemical exposure incidents
Sulfuric Acid: Remove to fresh air immediately. If breathing is difficult, give oxygen. Consult a physician. Lead: Remove from exposure, gargle, wash nose and lips; consult physician.
Sulfuric Acid: Flush with large amounts of water for at least 15 minutes; remove contaminated clothing completely, including shoes. If symptoms persist, seek medical attention. Wash contaminated clothing before reuse. Discard contaminated shoes. Lead: Wash immediately with soap and water.
Sulfuric Acid and Lead: Flush immediately with large amounts of water for a least 15 minutes while lifting lids. Seek immediate medical attention if eyes have been exposed directly to acid.
Sulfuric Acid: Give large quantities of water; do not induce vomiting or aspiration into the lungs may occur and can cause permanent injury or death; consult a physician. Lead: Consult physician immediately.
Immediate Medical Attention
Consult a physician for all exposure routes. Seek immediate medical attention if eyes have been exposed directly to acid.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2; foam; dry chemical. Use appropriate media for surrounding fire.
Do not use carbon dioxide directly on cells.
Highly flammable hydrogen gas is generated during charging and operation of batteries. Water applied to electrolyte generates heat and causes it to spatter. Strings of series connected batteries may still pose risk of electric shock even when charging equipment is shut down.
If batteries are on charge, shut off power. Keep sparks or other sources of ignition away from batteries. Do not allow metallic materials to simultaneously contact negative and positive terminals of cells and batteries. Follow manufacturer's instructions for installation and service.
Firefighter Protection
Use positive pressure, self-contained breathing apparatus. Wear acid-resistant clothing, gloves, face and eye protection. Avoid breathing vapors.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop flow of material, contain/absorb small spills with dry sand, earth, and vermiculite. Do not use combustible materials. If possible, carefully neutralize spilled electrolyte with soda ash, sodium bicarbonate, lime, etc.
contain/absorb small spills with dry sand, earth, and vermiculite
Acid must be managed in accordance with local, state, and federal requirements. Consult state environmental agency and/or federal EPA.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Unless involved in recycling operations, do not breach the casing or empty the contents of the battery. Handle carefully and avoid tipping, which may allow electrolyte leakage. Keep containers tightly closed when not in use. If battery case is broken, avoid contact with internal components. Keep vent caps on and cover terminals to prevent short circuits. Place cardboard between layers of stacked automotive batteries to avoid damage and short circuits. Use banding or stretch wrap to secure items for shipping. Wear face and eye protection when near batteries being charged.
Store batteries in cool, dry, well-ventilated areas with impervious surfaces and adequate containment in the event of spills. Batteries should also be stored under roof for protection against adverse weather conditions. Separate from incompatible materials.
Prohibit smoking.
Keep away from fire, sparks and heat. Prohibit smoking and avoid creation of flames and sparks nearby.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This product is stable under normal conditions at ambient temperature.
Will not occur
Prolonged overcharge; sources of ignition
Sulfuric Acid: combustibles, organic materials, strong reducing agents, metals, sulfur trioxide gas, strong oxidizers, water. Lead Compounds: strong acids, bases, halides, halogenates, potassium nitrate, permanganate, peroxides, nascent hydrogen, reducing agents. Arsenic compounds: strong oxidizers; bromine azide.
Sulfuric Acid: Sulfur trioxide, carbon monoxide, sulfuric acid mist, sulfur dioxide, and hydrogen sulfide. Lead Compounds: toxic metal fume, vapor, or dust; arsine gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2800
- Shipping Name
- BATTERIES, WET, NON-SPILLABLE
- Transport Class
- 8
Battery terminals must be protected against short circuits.
Battery Terminals must be protected against short Circuits. The words " NOT RESTRICTED" , SPECIAL PROVISION A67" must be provided on an airway bill when air waybill is issued.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Non-Spillable Lead Acid Battery known by?
Non-Spillable Lead Acid Battery is also known as: Industrial Battery, Traction Battery, Stationary Battery, Deep Cycle Battery
What is the hazard signal word for Non-Spillable Lead Acid Battery?
The signal word is danger.
What is the physical form of Non-Spillable Lead Acid Battery?
Non-Spillable Lead Acid Battery is a liquid appearing as manufactured article: no apparent odor. electrolyte is a clear liquid with a sharp, penetrating, pungent odor. . It has sharp, penetrating, pungent odor odor.
What are the hazard statements for Non-Spillable Lead Acid Battery?
This substance has 9 hazard statements:
- H203: Explosive, fire, blast, or projection hazard.
- H242: May form explosive air/gas mixture during charging.
- H302 + H312 + H332: Harmful if swallowed, inhaled, or contact with skin
- H314: Causes severe skin burns and serious eye damage.
- H318: Causes skin irritation, serious eye damage.
- H350: May cause cancer if ingested or inhaled.
- H360: May damage fertility or the unborn child if ingested or inhaled.
- H362: May cause harm to breast-fed children
- H372: Causes damage to central nervous system, blood and kidneys through prolonged or repeated exposure.