NextSDS Logo
Safety Data Sheet EN

3MTM Air Tool Lubricant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
3MTM Air Tool Lubricant
Product Code
28828, 20451, 20466, 20467
Synonyms
3MTM Air Tool and Compressor Lubricant

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricating Oil for Tools

Manufacturers & Suppliers

3

3M

manufacturer

3M Center, St. Paul, MN 55144-1000, USA

1-888-364-3577

Emergency Contacts

Emergency Contact

1-800-364-3577

24 hours

Emergency Contact

(651) 737-6501

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Oil --- 85 - 95% No
Lubricants --- 5 - 15% No
Petroleum Distillates --- 0.1 - 1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No need for first aid is anticipated.

Skin contact

No need for first aid is anticipated.

Eye contact

Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing.

Ingestion

Rinse mouth.

Immediate Medical Attention

If signs/symptoms persist, get medical attention. If you feel unwell, get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use a carbon dioxide or dry chemical extinguisher to extinguish.

Specific hazards

None inherent in this product.

Firefighter Protection

No special protective actions for fire-fighters are anticipated.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate area. Ventilate the area with fresh air.

Large spill

For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.

Environmental

Avoid release to the environment.

Cleanup methods

Mix in sufficient absorbent until it appears dry. Collect as much of the spilled material as possible. Clean up residue with an appropriate solvent selected by a qualified and authorized person.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.)

Storage

Store away from heat. Store away from acids. Store away from oxidizing agents.

Hygiene

Do not eat, drink or smoke when using this product. Wash thoroughly after handling.

Fire prevention

Store away from heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapors/spray. If ventilation is not adequate, use respiratory protection equipment.

Hands

No chemical protective gloves are required.

Eyes

None required.

Respiratory

None required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
No Data Available
Solubility In Fat
---
Relative Density
0.88 [@ 20 °C] [Ref Std: WATER=1]
Solubility In Water
---
Colour Intensity
---
Metal Corrosion
---
Properties Status
---
Physical State
Liquid
Dynamic Viscosity
---
Boiling Point
230 °C
Decomposition Temperature
No Data Available
Lower Explosive Limit
No Data Available
Evaporation Rate
No Data Available
Auto Ignition Temperature
No Data Available
Molecular Weight
---
Physical State Data
liquid
Melting Point
Not Applicable
Explosive Limits
---
Density
---
Crystallisation Point
---
Form
---
Appearance
Mild petroleum odor, clear light amber liquid
Solubility
---
Softening Point
---
State Under Standard Conditions
---
Ph
No Data Available
Solidification Point
---
Vapor Pressure
No Data Available
Colour
clear light amber
Relative Evaporation Rate
---
Bulk Density
---
Flammability
Not Applicable
Flash Point
138 °C [Test Method: Pensky-Martens Closed Cup]
Cloud Point
---
Freezing Point
---
Partition Coefficient
No Data Available
Odor
Mild petroleum odor
Vapor Density
No Data Available
Odor Threshold
No Data Available
Voc Content
0.22 % [Details: Calculated]
Kinematic Viscosity
35.4 centistoke [@ 40 °C] [Test Method: Tested per ASTM protocol] [Details: 10 wt. D-445]; 6.1 centistoke [@ 100 °C] [Test Method: Tested per ASTM protocol] [Details: 10 wt. D-445]
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

This material is considered to be non reactive under normal use conditions.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Sparks and/or flames

Incompatible

Strong oxidizing agents, Reducing agents, Strong acids

Decomposition

None known. Refer to section 5.2 for hazardous decomposition products during combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is 3MTM Air Tool Lubricant known by?

3MTM Air Tool Lubricant is also known as: 3MTM Air Tool and Compressor Lubricant

What is the hazard signal word for 3MTM Air Tool Lubricant?

The signal word is no signal word.

What is the physical form of 3MTM Air Tool Lubricant?

3MTM Air Tool Lubricant is a liquid appearing as mild petroleum odor, clear light amber liquid with clear light amber color. It has mild petroleum odor odor.

What is 3MTM Air Tool Lubricant used for?

Lubricating Oil for Tools

What is the melting point of 3MTM Air Tool Lubricant?

The melting point is Not Applicable and the boiling point is 230 °C.