Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ADBLUE®
Product Code
35161

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reducing agent for nitrogen oxides emitted from diesel engine-powered vehicles

Manufacturers & Suppliers

T

TotalEnergies Lubrifiants

manufacturer

562 Avenue du Parc de L'île, 92029 Nanterre Cedex FRANCE

+33 (0)1 41 35 40 00

T

TotalEnergies Marketing Belgium

national supplier

Handelsstraat, 93, Rue du Commerce, B-1040 BRUSSEL - BRUXELLES, België - Belgique

+32 (0)22 889 933

Emergency Contacts

Hopital Militaire Reine Astrid - Militair Hospitaal Koningin Astrid

+32 (0)2 264 48 48

Algemeen centrum Ziekenhuis

+32 (0)3 217 71 11

Centre Universitaire UZ Gand-Universitair Ziekenhuis UZ Gent

+32 (0)9 240 34 90

U.Z. Leuven

+32 (0)16 34 87 50

Hôpital Saint Joseph et Sainte Thérèse, section I.M.T. R

+32 (0)71 44 80 00

CHU Liège domaine Universitaire du Sart Tilman

+32 (0)4 366 72 94

Poison center

+32 (0)70 245 245

Emergency telephone

+44 1235 239670

S.O.S TotalEnergies Marketing Belgium

+32 (0)78 15 51 51

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Precautionary Statements

Not applicable.
Not applicable.
Not applicable.
Not applicable.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam. Sand.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Hydrocarbon-proof gloves, nitrile rubber, Fluorinated rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. In case of prolonged contact with the product, it is recommended to wear gloves complying with ISO 21420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0.38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields. EN 166

Respiratory

None under normal use conditions

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour Intensity
---
Voc Content
---
Kinematic Viscosity
---
State Under Standard Conditions
---
Odor
Ammoniacal.
Metal Corrosion
---
Cloud Point
---
Relative Density
1.087 to 1.093 [ISO 2811-3]
Relative Evaporation Rate
---
Melting Point
-11°C
Partition Coefficient
-1.73
Density
1.087 to 1.093 g/cm³ [20°C] [ISO 2811-3]
Explosive Limits
---
Physical State
Liquid.
Solubility
Easily soluble in the following materials: cold water and hot water.
Appearance
---
Solubility In Water
---
Solidification Point
---
Vapor Pressure
2.3 kPa
Physical State Data
liquid
Properties Status
---
Lower Explosive Limit
---
Flammability
---
Boiling Point
100°C
Odor Threshold
Not available.
Auto Ignition Temperature
Not applicable.
Bulk Density
---
Crystallisation Point
---
Vapor Density
Not available.
Freezing Point
---
Decomposition Temperature
Not available.
Upper Explosive Limit
---
Molecular Weight
---
Dynamic Viscosity
---
Solubility In Fat
---
Ph
9 to 10
Softening Point
---
Form
---
Colour
Colorless.
Evaporation Rate
Not available.
Flash Point
Not applicable.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid increased storage temperature.

Incompatible

Nitrites nitrates Strong oxidizing agents

Decomposition

Carbon dioxide, carbon monoxide, Ammonia, anhydrous, Vapor

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ADBLUE®?

The signal word is no signal word.

What is the physical form of ADBLUE®?

ADBLUE® is a liquid. with colorless. color. It has ammoniacal. odor.

What is the solubility of ADBLUE®?

Easily soluble in the following materials: cold water and hot water.

What is ADBLUE® used for?

Reducing agent for nitrogen oxides emitted from diesel engine-powered vehicles

What are the hazard statements for ADBLUE®?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of ADBLUE®?

The melting point is -11°C and the boiling point is 100°C.