Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ADBLUE®
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reducing agent for nitrogen oxides emitted from diesel engine-powered vehicles
Manufacturers & Suppliers
TotalEnergies Lubrifiants
manufacturer
562 Avenue du Parc de L'île, 92029 Nanterre Cedex FRANCE
+33 (0)1 41 35 40 00
TotalEnergies Marketing Nederland N.V.
national supplier
Pr. Catharina-Amaliastraat 5, 2496 XD Den Haag NEDERLAND
+31 (0) 70-3180480
Emergency Contacts
National Poison Information Center (NVIC)
+31 (0) 88 755 8000
Emergency Contact
+44 1235 239670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ammonia EC: 215-647-6 | 1336-21-6 | 0.3% | Yes |
| Urea | --- | 32% | No |
Aqueous solution: Urea (32%), water
First Aid Measures
Emergency procedures for chemical exposure incidents
Move exposed person to fresh air.
Symptoms: Not an expected route of exposure.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
Symptoms: No specific data.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.
Symptoms: pain or irritation, watering, redness
Wash out mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.
Symptoms: No specific data.
Immediate Medical Attention
Get medical attention if irritation or symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Non-combustible. Use extinguishing media suitable for surrounding materials. Carbon dioxide (CO₂), water spray dry chemical powder Sand.
None known.
In a fire or if heated, a pressure increase will occur and the container may burst.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). See Section 10 for incompatible materials before handling or use.
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.
Goggles, face shield or other full-face protection should be worn if there is a risk of direct exposure to aerosols or splashes or when material is handled hot. Ensure that eyewash stations and safety showers are close to the workstation location.
None under normal use conditions. If these are not sufficient to maintain exposure below the OEL, suitable respiratory protection must be worn (Type A/P1).
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Non-skid safety shoes or boots
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Temperatures above 80°C
strong acids, Strong bases, nitrites, nitrates, Sodium hypochlorite, Calcium hypochlorite
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ADBLUE®?
The signal word is no signal word.
What is the physical form of ADBLUE®?
ADBLUE® is a liquid. with colorless. color. It has ammoniacal. odor.
What is ADBLUE® used for?
Reducing agent for nitrogen oxides emitted from diesel engine-powered vehicles
What is the melting point of ADBLUE®?
The melting point is -11°C and the boiling point is 100°C.