Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dipropylene glycol (mixture of isomers) for synthesis
- Product Code
- 8.03265
Regulatory Identifiers
- CAS Number
- 25265-71-8 Check regulations →
Identified Uses
Chemical for synthesis
Manufacturers & Suppliers
Merck Life Science BV
manufacturer
Ildefonse Vandammestraat 5/7B, B-1560 HOEILAART
+32 (0)3 899-1301
Emergency Contacts
CHEMTREC
+(32) 28 083237
Anti-poison centre
070 245245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Formula : C6H14O3 Molecular weight : 134,18 g/mol CAS-No. : 25265-71-8 EC-No. : 246-770-3
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| C6H14O3 EC: 246-770-3 | 25265-71-8 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water Foam Carbon dioxide (CO2) Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides. Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air on intense heating. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb®). Dispose of properly. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
1,2-Propylene glycol diacetate for synthesis
CAS: 623-84-7
Di(propylene glycol) butyl ether, mixture of isomers
CAS: 29911-28-2
Di(propylene glycol) methyl ether, mixture of isomers
CAS: 34590-94-8
Tri(propylene glycol) methyl ether, mixture of isomers
CAS: 25498-49-1
Di(propylene glycol) methyl ether acetate, mixture of isomers
CAS: 88917-22-0
dipropylene glycol
CAS: 25265-71-8
Diethylene glycol diethyl ether for synthesis
CAS: 112-36-7
Triethylene glycol for synthesis
CAS: 112-27-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Not required; except in case of aerosol formation.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Forms explosive mixtures with air on intense heating. A range from approx. 15 Kelvin below the flash point is to be rated as critical.
Violent reactions possible with: Oxidizing agents
Strong heating.
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dipropylene glycol (mixture of isomers) for synthesis?
The signal word is no signal word.
What is the physical form of Dipropylene glycol (mixture of isomers) for synthesis?
Dipropylene glycol (mixture of isomers) for synthesis is a liquid with colorless color. It has odorless odor.
What is Dipropylene glycol (mixture of isomers) for synthesis used for?
Chemical for synthesis
What is the melting point of Dipropylene glycol (mixture of isomers) for synthesis?
The melting point is < -20 °C and the boiling point is 227 °C at 0,98 hPa.