NextSDS Logo
Safety Data Sheet EN

DEPC

CAS 1609-47-8
EC 216-542-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DEPC
Product Code
A0881
Chemical Name
DEPC

Regulatory Identifiers

CAS Number
1609-47-8 Check regulations →
EC Number
216-542-8 Check regulations →

Identified Uses

Biochemistry Laboratory chemicals

Manufacturers & Suppliers

A

AppliChem GmbH

manufacturer

Ottoweg 4, D-64291 Darmstadt

+49 (0)6151 93570

Emergency Contacts

Emergency Contact

+49(0)6151 93570

Mo-Th 08:00 - 17:00 h; Fr 08:00 - 14:30 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H332
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H335

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 + H332 Harmful if swallowed or if inhaled.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
P280 Wear protective gloves / eye protection / face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Diethyl pyrocarbonate EC: 216-542-8 1609-47-8 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air or oxygen; call for doctor. In case of unconsciousness place patient stably in side position for transportation. Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Skin contact

Call a doctor immediately. Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

make victim drink water (maximum of 2 drinking glasses). Call a doctor immediately.

Immediate Medical Attention

Involve doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

In case of fire, the following can be released: Carbon monoxide and carbon dioxide

Instructions

Contain escaping vapours with water.

Firefighter Protection

Mouth respiratory protective device. Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid substance contact. Do not inhale steams/aerosols.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Clean up affected area.

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.

Storage

Keep container tightly sealed. Store receptacle in a well ventilated area. Store under lock and key and with access restricted to technical experts or their assistants only.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Butyl rubber, BR. Recommended thickness of the material: ≥ 0.70 mm. Value for the permeation: Level ≥ 480 min. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: ≥ 0.40 mm. Value for the permeation: Level ≥ 30 min.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device only when aerosol or mist is formed. Recommended filter device for short term use: Filter ABEK

Skin/Body

Use protective suit.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Characteristic
Odor Threshold
Not determined
Ph
Not determined
Melting Point
Undetermined
Boiling Point
160-163 °C
Flash Point
69 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined
Vapor Pressure
Not determined
Vapor Density
Not determined
Relative Density
Not determined
Bulk Density
---
Density
1.122 g/cm³
Flammability
Not applicable
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
Not determined
Decomposition Temperature
Not determined
Solubility
---
Partition Coefficient
Not determined
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
162.14 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined
Kinematic Viscosity
Not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

No further relevant information available.

Hazardous reactions

Reacts with acids, alkalis and oxidising agents. ammonium compounds

Avoid

Heating

Incompatible

acids, alkalis, oxidising agents, ammonium compounds

Decomposition

Thermal decomposition

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DEPC?

The signal word is warning.

What is the physical form of DEPC?

DEPC is a liquid with colourless color. It has characteristic odor.

What is DEPC used for?

Biochemistry Laboratory chemicals

What are the hazard statements for DEPC?

This substance has 4 hazard statements:

  • H302 + H332: Harmful if swallowed or if inhaled.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.

What is the melting point of DEPC?