Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ionify System Reagent S4 (iSysR S4)
- Product Code
- 09496548190
- Chemical Name
- methanol
Regulatory Identifiers
- CAS Number
- N/A
- EC Number
- 200-659-6 Check regulations →
- REACH No.
- 01-2119433307-44-0268
Identified Uses
Laboratory chemicals, Refer to product literature for further details.
Manufacturers & Suppliers
Roche Diagnostics Limited
manufacturer
Charles Avenue Burgess Hill RH15 9RY West Sussex United Kingdom
+44 1444 256000
Emergency Contacts
Product Safety / Vigilance (Roche Diagnostics Ltd.)
+44 (0)808 100 1920
Product Safety / Vigilance (Roche Diagnostics Ltd.)
1800 409 564
NPIS
+44 344 892 0111
NHS Direct in Wales
111
NHS Direct in Wales
+44 845 4647111
NHS in England/NHS 24 in Scotland
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methanol EC: 200-659-6 | 67-56-1 | 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If on skin, rinse well with water. If on clothes, remove clothes.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital.
Immediate Medical Attention
Take victim immediately to hospital.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.
Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13).
Materials: non-combustible absorbent material
Related Products
Similar products with comparable safety profiles
perfectION™ Ion Electrolyte B Reference Electrode Filling Solution
---
perfectION™ ion electrolyte B
---
SODIUM SULFITE, REAGENT, ACS
CAS: 7757-83-7
perfectION™ ion ISA solid state ISE
---
Ion exchanger I (strongly acidic cation exchanger, H⁺-form) GR for analysis Reag. Ph Eur
---
Ionic Strength Adjustor for Solid State Ion Selective Electrodes
---
ELECTROLYTE A2-I
---
NEFA FS Reagent R1
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of aerosol. Do not breathe vapours/dust. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharges. Provide sufficient air exchange and/or exhaust in work rooms. Container may be opened only under exhaust ventilation hood. Open drum carefully as content may be under pressure.
Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Observe label precautions.
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
Do not spray on a naked flame or any incandescent material. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Use only explosion-proof equipment. Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines.
In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. Remarks: Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. This recommendation is only valid for the product mentioned in the safety data sheet and provided by us and for the application specified by us. The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye wash bottle with pure water Tightly fitting safety goggles
Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Equipment should conform to EN 14387. Filter type: Organic gas and low boiling vapour type (AX)
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No decomposition if stored and applied as directed. Vapours may form explosive mixture with air.
Heat, flames and sparks.
Not applicable
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1230
- Shipping Name
- METHANOL
- Transport Class
- 3 (6.1)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ionify System Reagent S4 (iSysR S4)?
The signal word is danger.
What is the physical form of Ionify System Reagent S4 (iSysR S4)?
Ionify System Reagent S4 (iSysR S4) is a liquid appearing as liquid with colourless color. It has pungent odor.
What is Ionify System Reagent S4 (iSysR S4) used for?
Laboratory chemicals, Refer to product literature for further details.
What are the hazard statements for Ionify System Reagent S4 (iSysR S4)?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled.
- H370: Causes damage to organs (Eyes).
What is the melting point of Ionify System Reagent S4 (iSysR S4)?
The melting point is -97,8 °C and the boiling point is 64,7 °C (1.013 hPa).