NextSDS Logo
Safety Data Sheet EN

NEFA FS Reagent R1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NEFA FS Reagent R1
Product Code
1 5781 XX XX XXX

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for in-vitro diagnostics in human samples

Manufacturers & Suppliers

DiaSys Diagnostic Systems GmbH logo

DiaSys Diagnostic Systems GmbH

manufacturer

Alte Strasse 9, 65558 Holzheim

+49 (0) 6432-9146-0

http://www.diasys.de

Emergency Contacts

Infraserv

+49 (0) 69-305-6418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution of anorganic salts and organic compounds.

Chemical Name CAS Number Concentration Hazardous
Octylphenoxypolyethoxyethanol 9002-93-1 2.5% Yes
2-[bis(2-Hydroxyethyl)amino] ethanesulphonic acid EC: 233-465-5 10191-18-1 2% Yes

This mixture contains the following substances of very high concern (SVHC) which are included in the Candidate List according to Article 59 of REACH: Octylphenoxypolyethoxyethanol (EQC)

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air.

Skin contact

Change contaminated clothing. Remove residues with water.

Eye contact

Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. In case of troubles or persistent symptoms, consult an ophthalmologist.

Ingestion

Rinse mouth immediately and drink plenty of water. Seek medical attention. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Seek medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is non-combustible. Extinguishing materials should therefore be selected according to surroundings.

Specific hazards

Fires in the immediate vicinity may cause the development of dangerous vapours.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes.

Environmental

Do not allow to penetrate into soil, waterbodies or drains.

Cleanup methods

Soak up with absorbent materials. Wash spill area with plenty of water.

Materials: sand, siliceus earth, acid- or universal binder

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Keep all containers, equipment and working place clean.

Storage

Keep containers tightly closed and at a temperature between 2 °C and 8 °C. Do not freeze. Protect from light. Keep sterile.

Hygiene

Keep all containers, equipment and working place clean.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation and/or an exhaust system in the work area.

Hands

Protective gloves according to EN 374. Glove material: Butyl caoutchouc (butyl rubber)-Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.

Eyes

Tightly sealed goggles according to EN 166.

Respiratory

Use a breathing protection against vapours/aerosol. Use combination filter type A/P according to EN 14387.

Skin/Body

Lab coat

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Appearance
colourless up to weak brown, clear
Voc Content
---
Solubility
---
Flash Point
not combustible
Metal Corrosion
---
Ph
7.0 at 25 °C
Cloud Point
---
Physical State
liquid
Upper Explosive Limit
no data available
Molecular Weight
---
Density
1.0165 g/mL at 20 °C
Lower Explosive Limit
no data available
Crystallisation Point
---
Physical State Data
liquid
Dynamic Viscosity
no data available
Softening Point
---
Partition Coefficient
no data available
Boiling Point
no data available
Solidification Point
---
Flammability
no data available
Relative Density
---
Vapor Pressure
no data available
Bulk Density
---
Solubility In Fat
---
Properties Status
---
State Under Standard Conditions
---
Colour
colourless up to weak brown
Odor Threshold
no data available
Vapor Density
no data available
Melting Point
no data available
Form
liquid
Evaporation Rate
no data available
Colour Intensity
---
Kinematic Viscosity
---
Decomposition Temperature
no data available
Explosive Limits
---
Freezing Point
no data available
Odor
odourless
Auto Ignition Temperature
no data available
Solubility In Water
completely miscible
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

refer to 10.3

Hazardous reactions

No hazardous reactions known.

Avoid

Protect against heat /sun rays.

Incompatible

no data available

Decomposition

In case of fire may be liberated: Nitrogen oxides (NOx), sulphur oxides, Carbon monoxide and carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Special waste. Dispose of waste according to applicable legislation.

Disposal

Special waste. Dispose of waste according to applicable legislation.

Waste Codes

16 05 06* Laboratory chemicals consisting of or containing dangerous substances including mixtures of laboratory chemicals. EWC
15 01 02 Plastic packaging. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
not applicable
Shipping Name
Not restricted
Transport Class
not applicable
Packing Group
not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

For this substance a chemical safety assessment is not required.

Chemical Safety Assessment Not performed

Labelling of packaging with <= 125mL content: Signal word: Warning, Hazard statements: not applicable, Precautionary statements: not applicable

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NEFA FS Reagent R1?

The signal word is warning.

What is the physical form of NEFA FS Reagent R1?

NEFA FS Reagent R1 is a liquid appearing as colourless up to weak brown, clear with colourless up to weak brown color. It has odourless odor.

What is NEFA FS Reagent R1 used for?

Reagent for in-vitro diagnostics in human samples

What are the hazard statements for NEFA FS Reagent R1?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of NEFA FS Reagent R1?

The melting point is no data available and the boiling point is no data available.