Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PETRONAS URANIA LD7
- Product Code
- 71519
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Engine oil.
Uses advised against
This product should not be used for other purposes than those specified without the advice of an expert.
Manufacturers & Suppliers
PETRONAS LUBRICANTS ITALY S.P.A.
manufacturer
Via Santena 1, 10029 Villastellone (Torino)
+39.01196131
Emergency Contacts
Emergency Contact
+44 1235 239670
24h/7d
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Severely refined mineral and/or synthetic oils, additives.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Not classified oils | --- | 90 - 100% | No |
| Phenol, tetrapropylene-, sulfurized, carbonates, calcium salts, overbased | 122384-87-6 | 1 - 1.5% | Yes |
| Phenol, (tetrapropenyl) derivs EC: 616-100-8 | 74499-35-7 | 0.01 - 0.05% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Expose affected person to fresh air and obtain medical attention if necessary.
Remove contaminated clothes and shoes and rinse thoroughly with plenty of water and soap.
Rinse thoroughly with plenty of water for at least 10 minutes keeping eyelids open. Remove contact lenses if this can be done easily. In case of contact with hot product, rinse thoroughly with plenty of water to dissipate heat.
Symptoms: Pain and redness.
Wash out thoroughly the mouth with water.
Immediate Medical Attention
Obtain immediate medical attention for ingestion. In case of contact with hot product, obtain immediate medical attention to assess eye conditions and the correct treatment to be practiced. Obtain medical attention in case of development and persistence of pain and redness in eyes. Obtain medical attention if necessary for inhalation.
Medical Treatment
Refer to section 4.1.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
foam, carbon dioxide, dry chemical powder, water mist, Water, Carbon dioxide (CO2)
high pressure water jet
Cool down with water the containers don't get involved in fire to avoid their possible explosion.
Cool down with water the containers don't get involved in fire to avoid their possible explosion. Use water jet only to cool down surfaces exposed to fire.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid ingestion of product. Avoid contact with skin and eyes by wearing appropriate protective clothing. Avoid to breathe fumes and aerosols. Surfaces on which the product has been spilled may become slippery. Wear personal protection equipment. See protective measures under point 7 and 8.
Contain small spills with absorbent material.
dike, absorb and shovel up into suitable containers for disposal
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
shovel up into suitable containers for disposal
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid ingestion. Avoid frequent and prolonged skin contact and contact with eyes. Provide adequate ventilation to avoid mist or aerosol. Don't smoke or use spare flames; avoid contact with spark or other sources of ignition. Don't work near open container to avoid high concentration of vapours. Don't eat or drink during use.
Store under cover in the original container securely closed away from heat and sources of ignition. Do not store in the open air.
Don't eat or drink during use.
Don't smoke or use spare flames; avoid contact with spark or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Avoid production and diffusion of mist and aerosol with utilization of localized ventilation/aspiration or other required precautions.
Wear suitable gloves (i.e. neoprene, nitrile). Gloves should be changed when they show wear. The kind of gloves and the term of use must be decided from employer with regard to processing and to allow for DPI legislation and glove producer’s indications. Wear gloves only with clean hands.
Chemical goggles and face shield in case of oil splashes.
None required under normal conditions of use. Use approved full face respirator with organic vapour filter cartridge if the recommended exposure limits are exceeded.
Wear suitable protective clothing (for further information, refer to CEN-EN 14605); change it immediately in case of large contamination and wash it before subsequent use.
Adopt all required precaution to avoid product immission in environment (e.g., blasting systems, catch basins, ...). Refer to technical precautions and also to sections 6.2, 6.3, 7.2, 12 and 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under normal conditions of use.
Not expected under normal conditions of use.
This product must be kept far from heat sources. In any case, avoid exposing product to temperatures above the flash point.
Strong oxidizing agents, hard acids and bases.
Oxides of carbon, compounds of sulphur, phosphorus, nitrogen and hydrogen sulfide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
The product is not classified as dangerous for the environment. No specific eco-toxicological data is available.
12.2. PERSISTENCE AND DEGRADABILITY
Data on biodegradability of product are not available.
12.3. BIOACCUMULATIVE POTENTIAL
12.4. MOBILITY IN SOIL
The substance may cause contamination of environmental matrices; no specific mobility data is available.
12.5. RESULTS OF PBT AND VPVB ASSESSMENT
Not available.
12.6. OTHER ADVERSE EFFECTS
No known effects. Components containing branched alkylphenol impurities have been tested and are not toxic to aquatic organisms, therefore the impurity should not be used in the summation approach for aquatic toxicity classification.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recover if possible. In so doing, comply with the local and national regulations currently in force.
Dispose in accordance with local or national regulations via authorised person/licensed waste disposal contractor.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulation (EC) No 1272/2008, with all National and European related legislations - on classification, labelling and packaging of substances and mixtures; Regulation (EC) No 1907/2006 (REACH); Directives 89/391/EC, 89/654/EC, 89/655/EC, 89/656/EC, 90/269/EC, 90/270/EC, 90/394/EC, 90/679/EC; Directives 98/24/EC; Directive 1991/156/EC; Regulation 648/2004/EC on detergents; Directive 2012/18/UE (Seveso III).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PETRONAS URANIA LD7?
The signal word is no signal word.
What is the physical form of PETRONAS URANIA LD7?
PETRONAS URANIA LD7 is a liquid appearing as viscous 4,50012, . It has not relevant odor.
What is PETRONAS URANIA LD7 used for?
Engine oil.
What is the melting point of PETRONAS URANIA LD7?
The melting point is N.A. and the boiling point is 300 °C (572 °F).