NextSDS Logo
Safety Data Sheet EN

INDUSTRIAL OIL (ERTVELDE)

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INDUSTRIAL OIL (ERTVELDE)
Product Code
3WQ

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Process oil.

Manufacturers & Suppliers

T

TOTAL LUBRIFIANTS

manufacturer

562 Avenue du Parc de L'ile, 92029 Nanterre Cedex, FRANCE

+33 (0)1 41 35 40 00

Emergency Contacts

Emergency Contact

+44 1235 239670

ORFILA (INRS)

+33 (0)1 45 42 59 59

ANGERS

02 41 48 21 21

BORDEAUX

05 56 96 40 80

LILLE

08 00 59 59 59

LYON

04 72 11 69 11

MARSEILLE

04 91 75 25 25

NANCY

03 83 22 50 50

PARIS

01 40 05 48 48

STRASBOURG

03 88 37 37 37

TOULOUSE

05 61 77 74 47

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mineral oil of petroleum origin.

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 10 - 20% Yes
Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based EC: 276-738-4 72623-87-1 3 - 5% Yes
C14-16-18 Alkyl phenol EC: 931-468-2 --- 0.1 - 1% Yes
Polysulfides, di-tert-Bu EC: 273-103-3 68937-96-2 0.1 - 0.25% Yes

Product containing mineral oil with less than 3% DMSO extract as measured by IP 346.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep at rest in a position comfortable for breathing. If not breathing, give artificial respiration.

Symptoms: Not classified based on available data. Inhalation of vapors in high concentration may cause irritation of respiratory system.

Skin contact

Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Wash contaminated clothing before reuse.

Symptoms: Not classified based on available data. May produce an allergic reaction.

Eye contact

Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Keep eye wide open while rinsing.

Symptoms: Not classified based on available data.

Ingestion

Clean mouth with water. Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Call a physician or Poison Control Center immediately.

Symptoms: Not classified based on available data. Ingestion may cause gastrointestinal irritation, nausea, vomiting and diarrhea.

Immediate Medical Attention

Call a physician or Poison Control Center immediately. IN CASE OF SERIOUS OR PERSISTENT CONDITIONS, CALL A DOCTOR OR EMERGENCY MEDICAL CARE.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO₂). ABC powder. Foam. Water spray or fog.***

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Specific hazards

Incomplete combustion and thermolysis may produce gases of varying toxicity such as carbon monoxide, carbon dioxide, various hydrocarbons, aldehydes and soot. These may be highly dangerous if inhaled in confined spaces or at high concentration.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not touch or walk through spilled material. Contaminated surfaces will be extremely slippery.

Environmental

Do not allow material to contaminate ground water system. Prevent entry into waterways, sewers, basements or confined areas.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well-ventilated areas. Do not breathe vapors or spray mist. Avoid contact with skin, eyes and clothing.

Storage

Store at room temperature. Protect from moisture.

Hygiene

Ensure the application of strict rules of hygiene by the personnel exposed to the risk of contact with the product. When using, do not eat, drink or smoke. Wash hands before breaks and immediately after handling the product. Regular cleaning of equipment, work area and clothing is recommended. Do not use abrasives, solvents or fuels. Do not dry hands with rags that have been contaminated with product. Do not put product contaminated rags into workwear pockets.

Fire prevention

Take precautionary measures against static discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Apply technical measures to comply with the occupational exposure limits. Ensure adequate ventilation, especially in confined areas. When working in confined spaces (tanks, containers, etc.), ensure that there is a supply of air suitable for breathing and wear the recommended equipment.

Hands

Hydrocarbon-proof gloves. Fluorinated rubber. Nitrile rubber. In case of prolonged contact with the product, it is recommended to wear gloves complying with EN 420 and EN 374 standards, protecting at least for 480 minutes and having a thickness of 0,38 mm at least. These values are indicative only. The level of protection is provided by the material of the glove, its technical characteristics, its resistance to the chemicals to be handled, the appropriateness of its use and its replacement frequency. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

If splashes are likely to occur, wear.. Safety glasses with side-shields. EN 166.

Respiratory

None under normal use conditions. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Respirator with combination filter for vapour/particulate (EN 14387). Type A/P1. Warning! filters have a limited use duration. The use of breathing apparatus must comply strictly with the manufacturer's instructions and the regulations governing their choices and uses.

Skin/Body

Wear suitable protective clothing. Protective shoes or boots. Long sleeved clothing. Type 4/6.

Environmental

The product should not be allowed to enter drains, water courses or the soil.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
limpid
Colour
No information available
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
No information available
Ph
Not applicable
Melting Point
Not applicable
Boiling Point
No information available
Flash Point
Cleveland Open Cup (COC): > 200 °C
Freezing Point
No information available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available
Vapor Pressure
No information available
Vapor Density
No information available
Relative Density
0.873 @ 15 °C
Bulk Density
---
Density
873 kg/m³ @ 15 °C
Flammability
---
Upper Explosive Limit
No information available
Lower Explosive Limit
No information available
Explosive Limits
---
Auto Ignition Temperature
No information available
Decomposition Temperature
No information available
Solubility
---
Partition Coefficient
No information available
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
61.96 mm2/s @ 40 °C ISO 3104
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

None under normal processing.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Keep away from open flames, hot surfaces and sources of ignition. Keep away from heat and sparks.

Incompatible

Strong oxidizing agents.

Decomposition

Incomplete combustion and thermolysis may produce gases of varying toxicity such as carbon monoxide, carbon dioxide, various hydrocarbons, aldehydes and soot. Combustion products include sulphur oxides (SO2 and SO3) and Hydrogen sulphide H2S. Phosphorous oxides. Nitrogen oxides (NOx). Mercaptans. Zinc oxides. Silicon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Not classified based on available data.*** Acute aquatic toxicity - Product Information*** No information available.*** Acute aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | --- | --- | --- | --- | --- |

Not classified based on available data.

12.1 Toxicity

Acute aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | Distillates (petroleum), hydrotreated heavy paraffinic*** 64742-54-7 | EL50 (48h) > 100 mg/l (Pseudokirchnerella subcapitata - OECD 201) | EL50 (48h) > 10000 mg/l (Daphnia magna - OECD 202) | LL50 (96h) > 100 mg/l (Oncorhynchus mykiss - OECD 203) | |

Acute aquatic toxicity - Component Information

Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based 72623-87-1 | EL50 (48h) > 100 mg (Pseudokirchnerella subcapitata - OECD 201) | EL50 (48h) > 10000 mg/l (Daphnia magna - OECD 202) LL50 (24h) > 10000 mg/l (Gammarus pulex - OECD 202) LL50 (48h) > 10000 mg/l (Gammarus pulex - OECD 202) LL50 (72h) > 10000 mg/l (Gammarus pulex - OECD 202) LL50 (96h) > 10000 mg/l (Gammarus pulex - OECD 202) | LL50 (96h) > 100 mg/l (Oncorhynchus mykiss - OECD 203)

12.1 Toxicity

Acute aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | C14-16-18 Alkyl phenol*** ^ | | EC50(48h) > 100 mg/l (Daphnia magna - static - OECD202) | | |

12.1 Toxicity

Acute aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | Polysulfides, di-tert-Bu*** 68937-96-2 | EC50 (72h) > 100 mg/l (Alga) | EC50 (48h) 63 mg/l (Daphnia magna) | | |

12.1 Toxicity

Chronic aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | Distillates (petroleum), hydrotreated heavy paraffinic*** 64742-54-7 | | NOEL (21d) 10 mg/l (Daphnia magna - QSAR Petrotox) | NOEL (14/28d) > 1000 mg/l (Oncorhynchus mykiss - QSAR Petrotox) | |

12.1 Toxicity

Chronic aquatic toxicity - Component Information | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Toxicity to microorganisms | | Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based*** 72623-87-1 | NOEL (72h) >= 100 mg/l (Pseudokirchnerella subcapitata - OECD 201) | NOEL (21d) 10 mg/l (Daphnia magna - OECD 211) | NOEL (14/28d) > 1000 mg/l (Oncorhynchus mykiss - QSAR Petrotox) NOEL (96h) > 100 mg/l (Pimephales promelas - OECD 203) | |

12.2. Persistence and degradability

General Information No information available.

12.3. Bioaccumulative potential

Product Information No information available.*** logPow No information available*** Component Information | Chemical Name | log Pow | | --- | --- |

12.3 Bioaccumulative potential

Component Information | Chemical Name | log Pow | | Distillates (petroleum), hydrotreated heavy paraffinic*** - 64742-54-7 | - |

12.3 Bioaccumulative potential

Lubricating oils (petroleum), C20-50, hydrotreated neutral oil-based - 72623-87-1: log Pow 4.1

12.3 Bioaccumulative potential

Polysulfides, di-tert-Bu 68937-96-2 log Pow: 6

12.4. Mobility in soil

Soil Given its physical and chemical characteristics, the product generally shows low soil mobility.*** Air Loss by evaporation is limited.*** Water The product is insoluble and floats on water.***

12.5. Results of PBT and vPvB assessment

PBT and vPvB assessment No information available.***

No information available.

12.6. Other adverse effects

General Information No information available.***

No information available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.

Disposal

Should not be released into the environment. Do not empty into drains. Where possible recycling is preferred to disposal or incineration.

Waste Codes

13 02 05 Waste codes are not product specific, but application specific. Waste codes should be assigned by the user based on the application for which the product was used. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

European Union

Chemical Safety Assessment Not performed

No information available

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INDUSTRIAL OIL (ERTVELDE)?

The signal word is no signal word.

What is the physical form of INDUSTRIAL OIL (ERTVELDE)?

INDUSTRIAL OIL (ERTVELDE) is a liquid appearing as limpid with no information available color. It has characteristic odor.

What is INDUSTRIAL OIL (ERTVELDE) used for?

Process oil.

What is the melting point of INDUSTRIAL OIL (ERTVELDE)?

The melting point is Not applicable and the boiling point is No information available.