NextSDS Logo
Safety Data Sheet EN

HiTEC® 6416 Fuel Additive

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 6416 Fuel Additive
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A
UFI Code
MWK1-KFT5-183W-WPNY

Identified Uses

Industrial. Formulation and blending of fuel additives and fuels.

Manufacturers & Suppliers

A

Afton Chemical Limited

manufacturer

Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England

+44 1344 304141

A

Afton Chemical S.R.L. (Woluwe)

manufacturer

Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium

+32 2 715 2211

A

Afton Chemical S.R.L. (Feluy Plant)

manufacturer

Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium

+32 67 286211

Emergency Contacts

Emergency Contact

+39 02 6610 1029

Emergency Contact

+43-13649237

24 hours a day, 7 days a week

Emergency Contact

+32-28083237

24 hours a day, 7 days a week

Emergency Contact

+359-32570104

24 hours a day, 7 days a week

Emergency Contact

+385-17776920

24 hours a day, 7 days a week

Emergency Contact

+420-228880039

24 hours a day, 7 days a week

Emergency Contact

+45-69918573

24 hours a day, 7 days a week

Emergency Contact

+358-942419014

24 hours a day, 7 days a week

Emergency Contact

+33-975181407

24 hours a day, 7 days a week

Emergency Contact

+49-69-6435-08409

24 hours a day, 7 days a week

Emergency Contact

+36-18088425

24 hours a day, 7 days a week

Emergency Contact

+353-19014670

24 hours a day, 7 days a week

Emergency Contact

+39-0245557031

24 hours a day, 7 days a week

Emergency Contact

+352-20202416

24 hours a day, 7 days a week

Emergency Contact

+31-858880596

24 hours a day, 7 days a week

Emergency Contact

+47-21930678

24 hours a day, 7 days a week

Emergency Contact

+48-223988029

24 hours a day, 7 days a week

Emergency Contact

+351-308801773

24 hours a day, 7 days a week

Emergency Contact

+421-233057972

24 hours a day, 7 days a week

Emergency Contact

+38-618888016

24 hours a day, 7 days a week

Emergency Contact

+46-852503403

24 hours a day, 7 days a week

Emergency Contact

+41-435082011

24 hours a day, 7 days a week

Emergency Contact

+380-947101374

24 hours a day, 7 days a week

Emergency Contact

+44-8708200418

24 hours a day, 7 days a week

Emergency Contact

+1-703-527-3887

24 hours a day, 7 days a week

Emergency Contact

+65 3163 8374

24 hours a day, 7 days a week

Emergency Contact

+61-290372994

24 hours a day, 7 days a week

Emergency Contact

4001-204937

24 hours a day, 7 days a week

Emergency Contact

+(91)-22-3354 3594

24 hours a day, 7 days a week

Emergency Contact

+81-345209637

24 hours a day, 7 days a week

Emergency Contact

+65-3158-1349

24 hours a day, 7 days a week

Emergency Contact

00-308-13-2549

24 hours a day, 7 days a week

Emergency Contact

+1-703-741-5979

24 hours a day, 7 days a week

Emergency Contact

1-800-424-9300

24 hours a day, 7 days a week

Emergency Contact

+43 1 406 43 43

Emergency Contact

+32 (0)70 245 245

Emergency Contact

+359 2 9154 233

Emergency Contact

+3851 2348 342

Emergency Contact

+357 1401

Emergency Contact

+420 224 91 92 93

Emergency Contact

+45 8212 1212

Emergency Contact

+372 16662

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

+30 210 779 3777

Emergency Contact

+36 80 201 199

Emergency Contact

+354 112

Emergency Contact

+371 67042473

Emergency Contact

+370 (85) 236 2052

Emergency Contact

+352 8002 5500

Emergency Contact

+31 (0)88 755 8000

Emergency Contact

+47 22 59 13 00

Emergency Contact

+351 800 250 250

Emergency Contact

+40 (0)21 318 36 06

8am – 3pm

Emergency Contact

+421 2 5477 4166

Emergency Contact

+386 112

Emergency Contact

+34 91 562 04 20

Emergency Contact

+46 112

Emergency Contact

+39 800 883 300

Emergency Contact

+39 055 794 7819

Emergency Contact

+39 800 183 459

Emergency Contact

+39 081 545 3333

Emergency Contact

+39 0382 24444

Emergency Contact

+39 06 305 4343

Emergency Contact

+39 06 4997 8000

Emergency Contact

+39 06 6859 3726

Emergency Contact

+39 800 011 858

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Irrit. Cat. 2 H315
Carc. Cat. 1B H350
STOT SE Cat. 3 H335
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapor.
H315 Causes skin irritation.
H335 May cause respiratory irritation.
H336 May cause drowsiness or dizziness.
H350 May cause cancer.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P201 Obtain special instructions before use.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P261 Avoid breathing vapor.
P273 Avoid release to the environment.
P280 Wear protective gloves, protective clothing and eye or face protection.
P308 + P313 IF exposed or concerned: Get medical advice or attention.
P352 IF ON SKIN: Wash with plenty of water.
P403 Store in a well-ventilated place.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Polyolefin alkyl phenol alkyl amine --- 65 - 75% Yes
Hydrocarbons, C9, aromatics EC: 918-668-5 64742-95-6 15 - 22% Yes
1,2,4-trimethylbenzene EC: 202-436-9 95-63-6 5 - 10% Yes
mesitylene EC: 203-604-4 108-67-8 1 - 2.7% Yes
cymene EC: 246-674-1 25155-15-1 0.3 - 0.5% Yes
cumene EC: 202-704-5 98-82-8 0.1 - 0.6% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: Can cause central nervous system (CNS) depression. May cause drowsiness or dizziness. May cause respiratory irritation. Adverse symptoms may include the following: respiratory tract irritation, coughing, nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse. Continue to rinse for at least 15 minutes.

Symptoms: Causes skin irritation. Adverse symptoms may include the following: irritation, redness.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No known significant effects or critical hazards. Adverse symptoms may include the following: pain or irritation, watering, redness.

Ingestion

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Can cause central nervous system (CNS) depression. No specific data.

Immediate Medical Attention

Get medical attention.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO₂.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Runoff to sewer may create fire or explosion hazard. This material is harmful to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Water polluting material. May be harmful to the environment if released in large quantities.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 30 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant. Approved/certified respirator with organic vapor cartridge.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid. [Clear.]
Colour
Yellow. [Light]
Colour Intensity
Light
Form
---
Odor
Hydrocarbon.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Closed cup: 40°C [Pensky-Martens]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
---
Relative Density
0.91
Bulk Density
---
Density
0.909 g/cm³ [15°C]
Flammability
Not applicable (liquid).
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C): 280 mm²/s (280 cSt) Minimum
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

oxidizing materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Product/ingredient name: Polyolefin alkyl phenol alkyl amine Result: Acute EC50 5.4 mg/l, Species: Algae, Exposure: 96 hours, Remarks: Based on data for a similar substance. Result: Chronic NOEC 3.65 mg/l, Species: Algae, Exposure: 96 hours, Remarks: Based on data for a similar substance. Result: Chronic NOEC 3.38 mg/l, Species: Daphnia, Exposure: 21 days, Remarks: Based on data for a similar substance.

12.1 Toxicity

Product/ingredient name: Hydrocarbons, C9, aromatics Acute EL50 3.1 mg/l, Algae - Raphidocelis subcapitata, 72 hours Acute EL50 4.5 mg/l, Daphnia - Daphnia magna, 48 hours, Based on data for a similar substance. Acute LL50 8.2 mg/l, Fish - Pimephales promelas, 96 hours, Based on data for a similar substance. Chronic NOEC 0.4 mg/l, Daphnia - Daphnia magna, 21 days, Based on data for a similar substance. Chronic NOEL 0.5 mg/l, Algae - Raphidocelis subcapitata, 72 hours Chronic NOEL 2.6 mg/l, Fish - Pimephales promelas, 14 days, Based on data for a similar substance.

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

Product/ingredient name: 1,2,4-trimethylbenzene. Result: Acute LC50 3.6 mg/l, Species: Daphnia - Daphnia magna, Exposure: 48 hours. Result: Acute LC50 7.72 mg/l, Species: Fish - Pimephales promelas, Exposure: 96 hours.

12.1 Toxicity

| Product/ingredient name | Result | Species | Exposure | Remarks | | --- | --- | --- | --- | --- | | mesitylene | Acute EC50 53 mg/l | Algae - Desmodesmus subspicatus | 48 hours | - | | | Acute LC50 6 mg/l | Crustaceans - Daphnia magna | 48 hours | - | | | Acute LC50 12.52 mg/l | Fish - Carassius auratus | 96 hours | - | | | Chronic EC10 16 mg/l | Algae - Desmodesmus subspicatus | 48 hours | - | | | Chronic NOEC 0.4 mg/l | Crustaceans - Daphnia magna | 21 days | - |

12.1 Toxicity

Product/ingredient name: cymene Acute EC50 5.8 mg/l, Algae, 72 hours, Based upon data for a similar product. Acute EC50 1.9 mg/l, Daphnia, 48 hours, Based on data for a similar substance. Acute LC50 2 mg/l, Fish, 96 hours, Based on data for a similar substance. Chronic NOEC 0.48 mg/l, Algae, 72 hours, Based on data for a similar substance. Chronic NOEC 0.46 mg/l, Daphnia - Daphnia magna, 21 days, Based on data for a similar substance. Chronic NOEC 0.69 mg/l, Fish, Based on data for a similar substance.

12.1 Toxicity

Product/ingredient name: cumene. EC50 >2000 mg/l (Micro-organism, 3 hours). Acute EC50 2.01 mg/l (Algae - Desmodesmus subspicatus, 72 hours). Acute EC50 2.14 mg/l (Crustaceans - Daphnia magna, 48 hours). Acute EC50 10.6 mg/l (Daphnia - Daphnia magna - Neonate, 48 hours). Acute LC50 4.8 mg/l (Fish - Oncorhynchus mykiss, 96 hours). Chronic EC10 1.35 mg/l (Algae - Desmodesmus subspicatus, 72 hours). Chronic NOEC 0.35 mg/l (Crustaceans - Daphnia magna, 21 days, QSAR result). Chronic NOEC 0.38 mg/l (Fish - D. rerio and P. promelas, 28 days, QSAR result).

12.2 Persistence and degradability

Product/ingredient name: mesitylene; Test: -; Result: 42 % - Not readily - 28 days; Remarks: -

12.2 Persistence and degradability

70 % - Readily - 20 days

12.1 Toxicity

Not available.

12.2 Persistence and degradability

Not available.

12.3 Bioaccumulative potential

Product/ingredient name: Hydrocarbons, C9, aromatics | LogPow: - | BCF: 10 to 2500 | Potential: high

12.4 Mobility in soil

Not available.

12.5 Results of PBT and vPvB assessment

Not available.

12.6 Endocrine disrupting properties

Not available.

12.7 Other adverse effects

Not available.

12.3 Bioaccumulative potential

Product/ingredient name: 1,2,4-trimethylbenzene | LogPow: 3.63 | BCF: 243 | Potential: low

12.3 Bioaccumulative potential

Product/ingredient name: mesitylene, LogPow: 3.42, BCF: 161, Potential: low

12.3 Bioaccumulative potential

Product/ingredient name: cymene, LogPow: 4.1, BCF: -, Potential: high

12.3 Bioaccumulative potential

| Product/ingredient name | LogPow | BCF | Potential | | --- | --- | --- | --- | | cumene | 3.55 | 35.48 | low |

12.4 Mobility in soil

Soil/water partition coefficient (Koc) : Not available. Mobility : Not available.

12.5 Results of PBT and vPvB assessment

This mixture does not contain any substances that are assessed to be a PBT or a vPvB.

The mixture does not contain any substances that are assessed to be a PBT or a vPvB.

12.6 Endocrine disrupting properties

Based on available data, the classification criteria are not met.

12.7 Other adverse effects

No known significant effects or critical hazards.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

13 07 03* other fuels (including mixtures) EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1993
Shipping Name
FLAMMABLE LIQUID, N.O.S. (Solvent naphtha, Trimethylbenzenes)
Transport Class
3
Packing Group
III
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Afton HiTEC® 6416 Fuel Additive regulatory information

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 6416 Fuel Additive?

The signal word is danger.

What is the physical form of HiTEC® 6416 Fuel Additive?

HiTEC® 6416 Fuel Additive is a liquid. appearing as liquid. [clear.] with yellow. [light] color. It has hydrocarbon. odor.

What is HiTEC® 6416 Fuel Additive used for?

Industrial. Formulation and blending of fuel additives and fuels.

What are the hazard statements for HiTEC® 6416 Fuel Additive?

This substance has 6 hazard statements:

  • H226: Flammable liquid and vapor.
  • H315: Causes skin irritation.
  • H335: May cause respiratory irritation.
  • H336: May cause drowsiness or dizziness.
  • H350: May cause cancer.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of HiTEC® 6416 Fuel Additive?

The melting point is Not available. and the boiling point is Not available..