Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ALKYLATBENZIN TYPE KWF 4T
- Product Code
- A03922
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- HSJU-W47F-PG1A-Q0Y3
Identified Uses
Fuel
Manufacturers & Suppliers
TotalEnergies Additives and Fuels Solutions
manufacturer
Place du Bassin, 69700 Givors
+33 (0) 4 72 49 27 00
TotalEnergies Marketing Belgium
national supplier
Handelsstraat, 93, Rue du Commerce, B-1040 BRUSSEL - BRUXELLES, België - Belgique
+32 (0)22 889 933
Emergency Contacts
National advisory body/Poison Center
+32 70 245 245
Supplier (info product)
+44 1235239670
SOS TotalEnergies Marketing Belgium (transport)
+32 78 15 51 51
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2,2,4,4,6-pentamethylheptane EC: 263-451-4 | 62199-62-6 | 1 - 2.5% | Yes |
| Isobutane EC: 200-857-2 | 75-28-5 | 0.1 - 1% | Yes |
| 2,2,4,6,6-pentamethylheptane EC: 236-757-0 | 13475-82-6 | 1 - 2.5% | Yes |
| Naphtha (petroleum), full-range alkylate, butane-contg. EC: 271-267-0 | 68527-27-5 | 50 - 75% | Yes |
| isopentane EC: 201-142-8 | 78-78-4 | 10 - 20% | Yes |
| Hydrocarbons, C7-C9, isoalkanes EC: 921-728-3 | 64741-66-8 | 10 - 25% | Yes |
| 2,2,4-trimethylpentane EC: 208-759-1 | 540-84-1 | 25 - 50% | Yes |
| 2,3,4-trimethylpentane EC: 209-292-6 | 565-75-3 | 10 - 25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: irritation, redness
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms: pain or irritation, watering, redness
Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
Extremely flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along the ground. Vapors may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Dilute with water and mop up if water-soluble. Absorb with an inert dry material. Wash spillages into an effluent treatment plant.
Related Products
Similar products with comparable safety profiles
ALKYLATBENZIN TYPE KWF 4T
UFI: K39U-S4HC-RG1A-WJ3K
B ULTRA ENGINE POWER 10W30 CK-4
---
Kawasaki K-Tech 4-Cycle Engine Oil, SAE 10W-30
---
D ULTRA ENGINE POWER 15W40 CK-4
---
MOBIL 1 RACING 4T 15W-50
---
ALKYLATE 300
UFI: S550-40YN-Y00Q-DURE
CHAMPION AGRILINE 4T SAE 30 SJ
---
DIESTERLUB 2T PLUS RED
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Do not swallow. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.
Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Repeated or prolonged exposure Glove material: Nitrile rubber; Glove thickness > 0.5 mm; Break through time > 480 min; standard : EN 374 Glove material: Fluorinated rubber; any thickness; Break through time > 480 min; standard : EN 374 Glove material: polyvinyl alcohol (PVA); any thickness; Break through time > 480 min; standard : EN 374 In case of contact through splashing Glove material: Nitrile rubber; Glove thickness > 0.3 mm; Break through time > 60 min; standard : EN 374
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. When using a mask or half mask : Respirator with a vapor filter (EN 14387). Respirator with combination filter for vapor/particulate, Type A/P2, Type AX. The use of breathing apparatus must comply strictly with the manufacturer's instructions and the regulations governing their choices and uses.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (see Section 7).
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapor to accumulate in low or confined areas.
oxidizing materials
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.7 Other adverse effects
No known significant effects or critical hazards.
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
Not available.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The mixture does not contain any substances that are assessed to be a PBT or a vPvB in a concentration >= 0,1 %.
12.6 Endocrine disrupting properties
The product does not contain any substance present at a concentration equal to or greater than 0.1% by mass with endocrine disrupting properties.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1203
- Shipping Name
- GASOLINE
- Transport Class
- 3
- Packing Group
- II
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The information stated in this section relates solely to the conformity of the chemical product with the countries Inventories. The information used to confirm the inventory status of this product may be based on additional data to the chemical composition shown in Section 3. Other regulations may apply for importation or marketing authorizations.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ALKYLATBENZIN TYPE KWF 4T?
The signal word is danger.
What is the physical form of ALKYLATBENZIN TYPE KWF 4T?
ALKYLATBENZIN TYPE KWF 4T is a liquid. with colorless. color. It has petroleum distillates odor.
What is ALKYLATBENZIN TYPE KWF 4T used for?
Fuel
What are the hazard statements for ALKYLATBENZIN TYPE KWF 4T?
This substance has 6 hazard statements:
- H224: Extremely flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of ALKYLATBENZIN TYPE KWF 4T?
The melting point is Not applicable. and the boiling point is 31 to 183°C [ISO 3405].