Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AMBRA MULTI G 10W-30
- Product Code
- 2693
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant for transmission system.
Uses advised against
This product should not be used for other purposes than those specified without the advice of an expert.
Manufacturers & Suppliers
PETRONAS LUBRICANTS ITALY S.P.A.
manufacturer
Via Santena 1 10029 Villastellone (Torino)
+39.01196131
Emergency Contacts
Pavia Poison Centre - IRCCS Maugeri Foundation
+39 0382 24444
24/24 h, 7/7 d
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate) EC: 224-235-5 | 4259-15-8 | 1 - 2% | Yes |
| C14-18 alpha-olefin epoxide, reaction products with boric acid EC: 939-580-3 | --- | 0.5 - 0.95% | Yes |
| Triphenyl phosphite EC: 202-908-4 | 101-02-0 | 0.1 - 0.25% | Yes |
| Not classified oils | --- | 70 - 90% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Expose affected person to fresh air and obtain medical attention if necessary.
Remove contaminated clothes and shoes and rinse thoroughly with plenty of water and soap.
Rinse thoroughly with plenty of water for at least 10 minutes keeping eyelids open. Remove contact lenses if this can be done easily. In case of contact with hot product, rinse thoroughly with plenty of water to dissipate heat.
Symptoms: pain and redness
Wash out thoroughly the mouth with water.
Immediate Medical Attention
Obtain immediate medical attention (Ingestion). Obtain immediate medical attention to assess eye conditions and the correct treatment to be practiced (Hot product eye contact).
Medical Treatment
Refer to section 4.1. N.A.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
foam, carbon dioxide, dry chemical powder, water mist, Water, Carbon dioxide (CO2)
None in particular. Avoid high pressure water jet.
Containers may explode if involved in fire.
Cool down with water the containers don't get involved in fire to avoid their possible explosion. Use water jet only to cool down surfaces exposed to fire.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid ingestion of product. Avoid contact with skin and eyes by wearing appropriate protective clothing. Avoid to breathe fumes and aereosols. Surfaces on which the product has been spilled may become slippery. Wear personal protection equipment.
Contain small spills with absorbent material.
dike, absorb and shovel up into suitable containers for disposal
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
shovel up into suitable containers for disposal
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid ingestion. Avoid frequent and prolonged skin contact and contact with eyes. Provide adequate ventilation to avoid mist or aereosol. Don't smoke or use spare flames; avoid contct with spark or other sources of ignition. Don't work near open container to avoid high concentration of vapours. Don't eat or drink during use.
Store under cover in the original container securely closed away from heat and sources of ignition. Do not store in the open air.
Don't eat or drink during use.
Don't smoke or use spare flames; avoid contct with spark or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Avoid production and diffusion of mist and aerosol with utilization of localized ventilation/aspiration or other required precautions.
Wear suitable gloves (i.e. neoprene, nitrile). Gloves should be changed when they show wear. The kind of gloves and the term of use must be decided from employer with regard to processing and to allow for DPI legislation and glove producer's indications. Wear gloves only with clean hands.
Chemical goggles and face shield in case of oil splashes.
None required under normal conditions of use. Use approved full face respirator with organic vapour filter cartridge if the recommended exposure limits are exceeded.
Wear suitable protective clothing (for further information, refer to CEN-EN 14605); change it immediately in case of large contamination and wash it before subsequent use.
Adopt all required precaution to avoid product immission in environment (e.g., blasting systems, catch basins, ...). Refer to technical precautions and also to sections 6.2, 6.3, 7.2, 12 and 13.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under normal conditions of use.
Not expected under normal conditions of use.
This product must be kept far from heat sources. In any case, avoid exposing product to temperatures above the flash point.
Strong oxidizing agents, hard acids and bases.
Oxides of carbon, compounds of sulphur, phosphorus, nitrogen and hydrogen sulfide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
12.1. TOXICITY
12.2. PERSISTENCE AND DEGRADABILITY
Data on biodegradability of product are not available.
12.3. BIOACCUMULATIVE POTENTIAL
Not available.
12.4. MOBILITY IN SOIL
12.5. RESULTS OF PBT AND VPVB ASSESSMENT
12.6. OTHER ADVERSE EFFECTS
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose in accordance with local or national regulations via authorised person/licensed waste disposal contractor.
Recover if possible. In so doing, comply with the local and national regulations currently in force.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Regulation (EC) No 1272/2008, with all National and European related legislations - on classification, labelling and packaging of substances and mixtures - and following adjustments to technical and scientific progress. Regulation (EC) No 1907/2006 (REACH), with all National and European related legislations.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AMBRA MULTI G 10W-30?
The signal word is no signal word.
What is the physical form of AMBRA MULTI G 10W-30?
AMBRA MULTI G 10W-30 is a liquid appearing as viscous . It has not relevant odor.
What is AMBRA MULTI G 10W-30 used for?
Lubricant for transmission system.
What are the hazard statements for AMBRA MULTI G 10W-30?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of AMBRA MULTI G 10W-30?
The melting point is N.A. and the boiling point is 300 °C (572 °F) ( ASTM D1120 ).