Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PARATONE 24EX
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Viscosity Index Improver
Uses advised against
Consult supplier when used other than those specified.
Manufacturers & Suppliers
Chevron Oronite S.A.S.
manufacturer
Le Corosa CS10022 1, rue Eugène et Armand Peugeot 92508 Rueil-Malmaison Cedex France
+33 1 46 39 36 00
Emergency Contacts
Chevron Emergency Information Centre
+(1) 510-231-0623
Emergency Contact
1 800 009 010
Emergency Contact
(+86) 4001-204937
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
CHEMTREC
(800) 424-9300
CHEMTREC
(703) 527-3887
Chevron Oronite Brasil Ltda
55 11 4478-1200
24 hours
ORFILA (INRS)
+33 (0)1 45 42 59 59
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
Emergency Contact
(800) 231-0623
24 hours
Emergency Contact
(510) 231-0623
24 hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Highly refined mineral oil (C15-C50) | --- | 86 - 94% | Yes |
In accordance with the Regulation (EC)No 1272/2008, Nota L, reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation contain <3% DMSO extract and are not carcinogenic.
First Aid Measures
Emergency procedures for chemical exposure incidents
If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.
Symptoms: coughing or respiratory discomfort
As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, apply a waterless hand cleaner, mineral oil, or petroleum jelly. Then wash with soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: Contact with the skin is not expected to be harmful.
As a precaution, remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do not induce vomiting. As a precaution, get medical advice.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
As a precaution, get medical advice (Ingestion). Get medical attention if coughing or respiratory discomfort occurs (Inhalation).
Medical Treatment
Not applicable.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Observe all relevant local and international regulations. Keep out unnecessary and unprotected personnel. Persons entering the contaminated area to correct the problem or to determine whether it is safe to resume normal activities must comply with all instructions in the Exposure Controls/PersonalProtection section.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.
The maximum short-term (<8 week(s)) storage temperature is 80°C. The maximum long-term (>8 week(s)) storage temperature is 45°C.
Wash thoroughly after handling.
Bonding and grounding may be necessary. Do not expose containers to heat, flame, sparks, static electricity, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Chemical Glove Material: Butyl (0.7 mm, 120 minutes), Nitrile (0.8 mm, 240 minutes), Viton Butyl (0.3 mm, 240 minutes).
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
A site-specific risk assessment should be conducted by an Occupational Hygienist or a Safety Professional to determine the type and use of respiratory protective equipment. Air purifying respirator: Vapors only: organic vapor cartridge (filter type A3 per EN 529:2005). Vapors and particulates (including generated mists): both an organic vapor cartridge & particulate filter (AP3 filter per EN 529:2005). Positive pressure air-supplying respirator: If airborne concentration limits exceed the maximum use concentration offered from an air purifying respirator. Refer to EN 529:2005, USA OSHA 1910.134, and/or other applicable local/regional/national/international standards for regulatory requirements.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Do not exceed handling and storage temperatures listed in SDS Section 7 (Handling and Storage).
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The material does not meet the criteria for PBT or vPvB.
12.6 Endocrine Disrupting Properties
The mixture does not contain any substances that are assessed as having endocrine disrupting properties.
12.7 Other adverse effects
No other adverse effects identified.
12.1 Toxicity
Based on available data, the classification criteria are not met
12.1 Toxicity
Based on available data, the classification criteria are not met.
12.2 Persistence and degradability
Bioaccumulative Potential
Based on available data, the classification criteria are not met.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible.
This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No components of this material were found on the regulatory lists searched (EU Directive 92/85/EEC, 2012/18/EU, 98/24/EC, 2004/37/EC, EU Regulation EC No. 689/2008, EU Regulation EC No. 850/2004, EU REACH Annex XVII, EU REACH Annex XIV, France INRS).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PARATONE 24EX?
The signal word is no signal word.
What is the physical form of PARATONE 24EX?
PARATONE 24EX is a liquid with colorless to yellow color. It has hydrocarbon odor odor.
What is the solubility of PARATONE 24EX?
Insoluble in water.
What is PARATONE 24EX used for?
Viscosity Index Improver
What is the melting point of PARATONE 24EX?
The melting point is No data available and the boiling point is No data available.