NextSDS Logo
Safety Data Sheet EN

HiTEC® 6595M Gasoline Additive

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 6595M Gasoline Additive
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial. Formulation and blending of fuel additives and fuels.

Manufacturers & Suppliers

A

Afton Chemical Limited

manufacturer

Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England

+44 1344 304141

A

Afton Chemical Limited

manufacturer

Ashburton Road West, Trafford Park, Manchester, M17 1SX, England

+44 161 876 5673

A

Afton Chemical SPRL (Feluy Plant)

manufacturer

Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium

+32 67 286211

Emergency Contacts

Emergency Contact

+43-13649237

24 hours a day, 7 days a week

Emergency Contact

+32-28083237

24 hours a day, 7 days a week

Emergency Contact

+359-32570104

24 hours a day, 7 days a week

Emergency Contact

+385-17776920

24 hours a day, 7 days a week

Emergency Contact

+420-228880039

24 hours a day, 7 days a week

Emergency Contact

+45-69918573

24 hours a day, 7 days a week

Emergency Contact

+358-942419014

24 hours a day, 7 days a week

Emergency Contact

+33-975181407

24 hours a day, 7 days a week

Emergency Contact

+36-18088425

24 hours a day, 7 days a week

Emergency Contact

+353-19014670

24 hours a day, 7 days a week

Emergency Contact

+39-0245557031

24 hours a day, 7 days a week

Emergency Contact

+352-20202416

24 hours a day, 7 days a week

Emergency Contact

+31-858880596

24 hours a day, 7 days a week

Emergency Contact

+47-21930678

24 hours a day, 7 days a week

Emergency Contact

+48-223988029

24 hours a day, 7 days a week

Emergency Contact

+351-308801773

24 hours a day, 7 days a week

Emergency Contact

+421-233057972

24 hours a day, 7 days a week

Emergency Contact

+38-618888016

24 hours a day, 7 days a week

Emergency Contact

+46-852503403

24 hours a day, 7 days a week

Emergency Contact

+41-435082011

24 hours a day, 7 days a week

Emergency Contact

+380-947101374

24 hours a day, 7 days a week

Emergency Contact

+44-8708200418

24 hours a day, 7 days a week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Irrit. Cat. 2 H315
Carc. Cat. 2 H351
STOT SE Cat. 3 H336
Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H226 Flammable liquid and vapor.
H304 May be fatal if swallowed and enters airways.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H351 Suspected of causing cancer.
H410 Very toxic to aquatic life with long lasting effects.

Precautionary Statements

P201 Obtain special instructions before use.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P235 Keep cool.
P241 Use explosion-proof electrical, ventilating, lighting and all material-handling equipment.
P261 Avoid breathing vapor.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P282 Wear eye or face protection.
P301 + P330 + P331 IF SWALLOWED: Do NOT induce vomiting.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P315 Get immediate medical attention.
P391 Collect spillage.
P403 Store in a well-ventilated place.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Solvent naphtha (petroleum), heavy aromatic EC: 265-198-5 64742-94-5 30 - 60% Yes
Polyolefin alkyl phenol alkyl amine --- 20 - 30% Yes
Polyether polyol --- 10 - 19.9% Yes
Solvent naphtha (petroleum), light aromatic EC: 265-199-0 64742-95-6 5 - 9.9% Yes
Benzene, 1,2,4-trimethyl- EC: 202-436-9 95-63-6 5 - 9.9% Yes
Naphthalene EC: 202-049-5 91-20-3 5 - 9.9% Yes
Benzene, 1,3,5-trimethyl- EC: 203-604-4 108-67-8 1 - 4.9% Yes
2-Ethyl hexanol EC: 203-234-3 104-76-7 1 - 4.9% Yes
Long-chain alkyl acid EC: 248-698-8 27859-58-1 0.1 - 0.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: May cause drowsiness or dizziness. Adverse symptoms may include the following: nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 15 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Causes skin irritation. Adverse symptoms may include the following: irritation, redness.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No known significant effects or critical hazards. Adverse symptoms may include the following: pain or irritation, watering, redness.

Ingestion

Get medical attention immediately. Call a poison center or physician. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.

Immediate Medical Attention

Get medical attention immediately. Call a poison center or physician.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapor. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along the ground. Vapors may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Runoff to sewer may create fire or explosion hazard. This material is very toxic to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant.

Materials: inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Avoid exposure - obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not get in eyes or on skin or clothing. Do not swallow. Avoid breathing vapor or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Storage

Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 120 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Respiratory

Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant. Approved/certified respirator with organic vapor cartridge.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Amber.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
-20°C
Boiling Point
>150°C
Flash Point
Closed cup: 56°C [Pensky-Martens. Minimum]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
<1 (butyl acetate = 1)
Vapor Pressure
<1.3 kPa [room temperature]
Vapor Density
>1 [Air = 1]
Relative Density
<1
Bulk Density
---
Density
0.93 g/cm³ [15°C]
Flammability
Not applicable. (liquid).
Upper Explosive Limit
≤13%
Lower Explosive Limit
0.6%
Explosive Limits
---
Auto Ignition Temperature
>450°C
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C): 0.1221 cm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Under recommended handling and storage conditions the product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapor to accumulate in low or confined areas.

Incompatible

oxidizing materials

Decomposition

Decomposition products may include the following materials: carbon dioxide carbon monoxide nitrogen oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

| Product / ingredient name | Result | Species | Exposure | | Solvent naphtha (petroleum), heavy aromatic | Acute EC50 <10 mg/l | Algae | 72 hours | | | Acute LC50 <10 mg/l | Daphnia | 48 hours | | | Acute LC50 <10 mg/l | Fish | 96 hours |

12.1 Toxicity

| Product / ingredient name | Result | Species | Exposure | | Trimethylbenzenes | Acute EC50 6.14 mg/l | Daphnia | 48 hours |

12.1 Toxicity

| Product / ingredient name | Result | Species | Exposure | | Naphthalene | Acute EC50 3.4 mg/l | Daphnia | 48 hours | | | Acute LC50 0.51 mg/l | Fish | 96 hours |

12.1 Toxicity

Conclusion/Summary : Toxic to aquatic life with long lasting effects.

Toxic to aquatic life with long lasting effects.

12.2 Persistence and degradability

Conclusion/Summary : Based on available data, the classification criteria are not met.

Based on available data, the classification criteria are not met.

12.2 Persistence and degradability

| Product / ingredient name | Aquatic half-life | Photolysis | Biodegradability | | Solvent naphtha (petroleum), heavy aromatic | - | - | Inherent |

12.2 Persistence and degradability

| Product / ingredient name | Aquatic half-life | Photolysis | Biodegradability | | Naphthalene | - | - | Inherent |

12.2 Persistence and degradability

| Product / ingredient name | Aquatic half-life | Photolysis | Biodegradability | | 2-Ethyl hexanol | - | - | Readily |

12.3 Bioaccumulative potential

| Product / ingredient name | LogPow | BCF | Potential | | 2-Ethyl hexanol | <1 | - | low |

12.4 Mobility in soil

Soil/water partition : Not available. coefficient (Koc) Mobility : Not available.

12.5 Results of PBT and vPvB assessment

PBT : Not applicable. vPvB : Not applicable.

12.6 Other adverse effects

: No known significant effects or critical hazards.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

Waste Codes

13 07 03* other fuels (including mixtures) EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
Flammable liquid, n.o.s. (Solvent naphtha, Trimethylbenzene)
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 6595M Gasoline Additive?

The signal word is danger.

What is the physical form of HiTEC® 6595M Gasoline Additive?

HiTEC® 6595M Gasoline Additive is a liquid. with amber. color. It has characteristic. odor.

What is HiTEC® 6595M Gasoline Additive used for?

Industrial. Formulation and blending of fuel additives and fuels.

What are the hazard statements for HiTEC® 6595M Gasoline Additive?

This substance has 6 hazard statements:

  • H226: Flammable liquid and vapor.
  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H351: Suspected of causing cancer.
  • H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of HiTEC® 6595M Gasoline Additive?

The melting point is -20°C and the boiling point is >150°C.