Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RADIACID 3094
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Chemical intermediate Solvent Food industry: additive Laboratory chemical Photographic chemical
Manufacturers & Suppliers
OLEON N.V.
manufacturer
Assenedestraat 2, 9940 Ertvelde - Belgium
+32 9 341 10 11
http://www.oleon.com
Emergency Contacts
SGS ERS
+32 3 575 55 55
SGS ERS
+1 888 765 6554
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| acetic acid EC: 200-580-7 | 64-19-7 | 80 - 100% | Yes |
Notes
Composition of product is highly variable
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.
Symptoms: Coughing. Dry/sore throat. Respiratory difficulties. Corrosion of the upper respiratory tract.
Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.
Symptoms: Caustic burns/corrosion of the skin.
Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.
Symptoms: Corrosion of the eye tissue.
Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.
Symptoms: Burns to the gastric/intestinal mucosa. Possible esophageal perforation. Blood in vomit. Diarrhoea. Shock. Low arterial pressure. Enlargement/affection of the liver. Decreased renal function.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.
Solid water jet ineffective as extinguishing medium.
DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. No direct explosion hazard.
Cool tanks/drums with water spray/remove them into safety. Do not move the load if exposed to heat.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes. Keep upwind. Seal off low-lying areas. Close doors and windows of adjacent premises. Stop engines and no smoking. No naked flames or sparks. Spark- and explosionproof appliances and lighting equipment. Keep containers closed.
Prevent soil and water pollution.
Clean contaminated surfaces with an excess of water and soap solution. Take up liquid spill into inert absorbent material, e.g.: dry sand/earth/vermiculite or powdered limestone.
Materials: dry sand/earth/vermiculite or powdered limestone, water and soap solution
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use spark-/explosionproof appliances and lighting system. Take precautions against electrostatic charges. Keep away from naked flames/heat. Keep away from ignition sources/sparks. Measure the concentration in the air regularly. Work under local exhaust/ventilation. Exhaust gas must be neutralised. Comply with the legal requirements. Remove contaminated clothing immediately. Clean contaminated clothing. Keep the substance free from contamination. Use corrosionproof equipment. Handle uncleaned empty containers as full ones. Thoroughly clean/dry the installation before use. Do not discharge the waste into the drain. Do not use compressed air for pumping over. Keep container tightly closed.
Keep container tightly closed.
Remove contaminated clothing immediately. Clean contaminated clothing. Keep the substance free from contamination.
Use spark-/explosionproof appliances and lighting system. Take precautions against electrostatic charges. Keep away from naked flames/heat. Keep away from ignition sources/sparks.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves against chemicals (EN374)
Safety glasses
Full face mask with filter type A at conc. in air > exposure limit. High vapour/gas concentration: self-contained respirator
Head/neck protection. Corrosion-proof clothing. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
On burning: release of (carbon monoxide - carbon dioxide).
No additional information available
No supplementary information available.
No supplementary information available.
No supplementary information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
Not classified as dangerous for the environment according to the criteria of Regulation (EC) No 1272/2008.
12.1 Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
12.2. Persistence and degradability
The substance is readily biodegradable in both soil and water.
12.3. Bioaccumulative potential
Not bioaccumulative.
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The substance does not meet the PBT or vPvB criteria of REACH regulation, annex XIII.
12.6. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Prevent dispersion by covering with dry absorbent, Scoop solid spill into closing containers, Scoop absorbed substance into closing containers, Clean contaminated surfaces with an excess of water and soap solution, Wash clothing and equipment after handling
Do not discharge into drains or the environment. Remove waste in accordance with local and/or national regulations. Hazardous waste shall not be mixed together with other waste. Different types of hazardous waste shall not be mixed together if this may entail a risk of pollution or create problems for the further management of the waste. Hazardous waste shall be managed responsibly. All entities that store, transport or handle hazardous waste shall take the necessary measures to prevent risks of pollution or damage to people or animals.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3265
- Shipping Name
- CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S. (acetic anhydride)
- Transport Class
- 8
- Packing Group
- II
274
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RADIACID 3094?
The signal word is danger.
What is the physical form of RADIACID 3094?
RADIACID 3094 is a liquid appearing as liquid. with colourless to yellow. color. It has characteristic odour. sweet odour. odor.
What is the solubility of RADIACID 3094?
Soluble in water. Soluble in ethanol. Soluble in ether. Soluble in acetone. Soluble in tetrachloromethane. Soluble in glycerol. Water: 602,9 g/l (25 °C) Ethanol: complete Ether: complete Acetone: complete
What is RADIACID 3094 used for?
Chemical intermediate Solvent Food industry: additive Laboratory chemical Photographic chemical
What are the hazard statements for RADIACID 3094?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour.
- H314: Causes severe skin burns and eye damage.
What is the melting point of RADIACID 3094?
The melting point is < 20 °C and the boiling point is > 100 °C.