Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- QC-F41 STAR
- Product Code
- QC-F41 STAR
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Liquid Processing Chemical for Cement Grinding based on polyalkanolamines and esters in aqueous solution, minimum 60% concentration
Manufacturers & Suppliers
T-CHEM FINANZ AG
manufacturer
Alte Landstrasse 101, 8800 Thalwil, Suisse
+41 21 803 07 37
Emergency Contacts
Emergency Contact
+41 21 803 07 37
available only during office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Get medical advice/attention immediately. Remove victim to fresh air, away from the accident scene. If the subject stops breathing, administer artificial respiration. Take suitable precautions for rescue workers.
Remove contaminated clothing. Rinse skin with a shower immediately. Get medical advice/attention.
Remove contact lenses, if present. Wash immediately with plenty of water for at least 30-60 minutes, opening the eyelids fully. Get medical advice/attention.
Have the subject drink as much water as possible. Get medical advice/attention. Do not induce vomiting unless explicitly authorised by a doctor.
Immediate Medical Attention
Get medical advice/attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The extinguishing equipment should be of the conventional kind: carbon dioxide, foam, powder and water spray.
None in particular.
Do not breathe combustion products.
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.
Firefighter Protection
Always wear full fire prevention gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Block the leakage if there is no hazard.
The product must not penetrate into the sewer system or come into contact with surface water or ground water.
Absorb the remainder with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Before handling the product, consult all the other sections of this material safety data sheet. Do not eat, drink or smoke during use. Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
Store only in the original container. Store the containers sealed, in a well ventilated place, away from direct sunlight.
Do not eat, drink or smoke during use. Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
As the use of adequate technical equipment must always take priority over personal protective equipment, make sure that the workplace is well aired through effective local aspiration.
Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability. The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration and type of use.
Wear a hood visor or protective visor combined with airtight goggles (see standard EN 166).
If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, use a mask with a type B filter whose class (1, 2 or 3) must be chosen according to the limit of use concentration. (see standard EN 14387). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.
Wear category I professional long-sleeved overalls and safety footwear (see Directive 89/686/EEC and standard EN ISO 20344). Wash body with soap and water after removing protective clothing.
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable in normal conditions of use and storage.
There are no particular risks with other substances in normal conditions of use.
No hazardous reactions are foreseeable in normal conditions of use and storage.
None in particular. However the usual precautions used for chemical products should be respected. ETHANEDIOL: avoid exposure to sources of heat and naked flames.
Information not available.
Information not available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The product does not contain any PBT or vPvB in percentage greater than 0.1%.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Reuse, when possible. Product residues should be considered special hazardous waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Healthcare controls: Workers exposed to this chemical agent must not undergo health checks, provided that available risk-assessment data prove that the risks related to the workers' health and safety are modest and that the 98/24/EC directive is respected.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for QC-F41 STAR?
The signal word is danger.
What is the physical form of QC-F41 STAR?
QC-F41 STAR is a liquid appearing as liquid with brown color. It has weak odor.
What is the solubility of QC-F41 STAR?
Soluble in water
What is QC-F41 STAR used for?
Liquid Processing Chemical for Cement Grinding based on polyalkanolamines and esters in aqueous solution, minimum 60% concentration
What are the hazard statements for QC-F41 STAR?
This substance has 1 hazard statement:
- H318: Causes serious eye damage
What is the melting point of QC-F41 STAR?
The melting point is -20°C and the boiling point is 105°C.