NextSDS Logo
Safety Data Sheet EN

POWERZOL™ ZE9640

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
POWERZOL™ ZE9640

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Aftermarket - Other

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL LIMITED logo

LUBRIZOL LIMITED

manufacturer

THE KNOWLE, NETHER LANE, HAZELWOOD, DERBYSHIRE, DE56 4AN, GB

(44) 01332-842211

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 --- 50 - 100% Yes
reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 --- 10 - 25% Yes
Mineral oil --- 1 - 10% Yes
Diphenylamine EC: 204-539-4 --- 0.1 - 0.25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Wash with soap and water. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.

Ingestion

Treat symptomatically. Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

No unusual fire or explosion hazards noted.

Instructions

No data available.

Firefighter Protection

Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations.

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces. Do not handle until all safety precautions have been read and understood. Obtain special instructions before use. Observe good industrial hygiene practices. Provide adequate ventilation. Use personal protective equipment as required. Launder contaminated clothing before reuse.

Storage

Store away from incompatible materials. See section 10 for incompatible materials.

Hygiene

Observe good industrial hygiene practices. Launder contaminated clothing before reuse.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

Respiratory

Consult with an industrial hygienist to determine the appropriate respiratory protection for your specific use of this material. A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Gloves, coveralls, apron, boots as necessary to minimize contact.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Amber
Colour
Amber
Colour Intensity
---
Form
liquid
Odor
Mild
Odor Threshold
No data available.
Ph
Not applicable
Melting Point
---
Boiling Point
No data available.
Flash Point
152 °C (Pensky-Martens Closed Cup)
Freezing Point
No data available.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available.
Vapor Pressure
No data available.
Vapor Density
---
Relative Density
0.860 - 0.9 (15.6 °C)
Bulk Density
7.33 lb/gal
Density
---
Flammability
No data available.
Upper Explosive Limit
No data available.
Lower Explosive Limit
No data available.
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
---
Partition Coefficient
No data available.
Solubility In Water
Insoluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
No data available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
65 mm2/s (40 °C); 9.2 mm2/s (100 °C) 144 mm2/s (25 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

excessive heat, ignition sources

Incompatible

oxidizing materials

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion. Diphenylamine and alkenes may also be released.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

### Fish Distillates (petroleum), hydrotreated heavy paraffinic LC 50 (Fathead Minnow, 96 h): > 100 mg/l

12.1 Toxicity

### Fish Mineral oil LC 50 (Fathead Minnow, 4 d): > 100 mg/l

12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

12.6 Endocrine disrupting properties

12.7 Other adverse effects

12.1 Toxicity

### Fish **Diphenylamine** LC 50 (Not reported, 2 d): 2.2 mg/l

12.1 Toxicity

Aquatic Invertebrates Distillates (petroleum), hydrotreated heavy paraffinic EC 50 (Water flea (Daphnia magna), 48 h): > 10,000 mg/l EC 50 (Water flea (Daphnia magna), 21 d): > 10 mg/l NOEC (Water flea (Daphnia magna), 21 d): 10 mg/l

12.1 Toxicity

### Aquatic Invertebrates Mineral oil EC 50 (Water flea (Daphnia magna), 2 d): > 10,000 mg/l EC 50 (Water flea (Daphnia magna), 21 d): > 10 mg/l NOEC (Water flea (Daphnia magna), 21 d): > 10 mg/l

12.1 Toxicity

Aquatic Invertebrates Diphenylamine EC 50 (Water flea (Daphnia magna), 2 d): 0.31 mg/l

12.1 Toxicity

### Toxicity to Aquatic Plants Distillates (petroleum), hydrotreated heavy paraffinic EC 50 (Algae (Pseudokirchneriella subcapitata), 72 h): > 100 mg/l NOEC (Algae (Pseudokirchneriella subcapitata), 72 h): >= 100 mg/l

12.1 Toxicity

Toxicity to Aquatic Plants Mineral oil EC 50 (Green algae (Scenedesmus quadricauda), 3 Days): > 100 mg/l

12.1 Toxicity

Toxicity to Aquatic Plants **Diphenylamine** EC 50 (Green algae (Selenastrum capricornutum), 3 d): 1.51 mg/l

12.2 Persistence and Degradability

Biodegradation Distillates (petroleum), hydrotreated heavy paraffinic OECD TG 301 F, 31 %, 28 d, Not readily degradable.

12.2 Persistence and Degradability

Biodegradation Mineral oil OECD TG 301 B, 31 %, 28 d, Not readily degradable.

12.2 Persistence and Degradability

Biodegradation Diphenylamine OECD TG 301 D, 26 %, 28 d, Not readily degradable.

12.3 Bioaccumulative potential

Bioconcentration Factor (BCF) reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate Bioconcentration Factor (BCF): 260

12.3 Bioaccumulative potential

Partition Coefficient n-octanol / water (log Kow) Diphenylamine Log Kow: 3.4 (calculated)

12.4 Mobility in soil:

No data available

12.5 Results of PBT and vPvB assessment

No data available

12.6 Endocrine disrupting properties:

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.

12.7 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is in compliance with major chemical inventories including AIIC, DSL/NDSL, IECSC, ENCS, ECL, NZIoC, PICCS, SWISS, TCSCA, and TSCA. REACH and UK REACH compliance status is available upon inquiry.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for POWERZOL™ ZE9640?

The signal word is no signal word.

What is the physical form of POWERZOL™ ZE9640?

POWERZOL™ ZE9640 is a liquid appearing as amber with amber color. It has mild odor.

What is POWERZOL™ ZE9640 used for?

Aftermarket - Other