Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- POWERZOL™ ZE9640
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Aftermarket - Other
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL LIMITED
manufacturer
THE KNOWLE, NETHER LANE, HAZELWOOD, DERBYSHIRE, DE56 4AN, GB
(44) 01332-842211
http://www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | --- | 50 - 100% | Yes |
| reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 | --- | 10 - 25% | Yes |
| Mineral oil | --- | 1 - 10% | Yes |
| Diphenylamine EC: 204-539-4 | --- | 0.1 - 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Wash with soap and water. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.
Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.
Treat symptomatically. Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
No data available.
Firefighter Protection
Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations.
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces. Do not handle until all safety precautions have been read and understood. Obtain special instructions before use. Observe good industrial hygiene practices. Provide adequate ventilation. Use personal protective equipment as required. Launder contaminated clothing before reuse.
Store away from incompatible materials. See section 10 for incompatible materials.
Observe good industrial hygiene practices. Launder contaminated clothing before reuse.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
Consult with an industrial hygienist to determine the appropriate respiratory protection for your specific use of this material. A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
Gloves, coveralls, apron, boots as necessary to minimize contact.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
excessive heat, ignition sources
oxidizing materials
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion. Diphenylamine and alkenes may also be released.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil:
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties:
The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is in compliance with major chemical inventories including AIIC, DSL/NDSL, IECSC, ENCS, ECL, NZIoC, PICCS, SWISS, TCSCA, and TSCA. REACH and UK REACH compliance status is available upon inquiry.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for POWERZOL™ ZE9640?
The signal word is no signal word.
What is the physical form of POWERZOL™ ZE9640?
POWERZOL™ ZE9640 is a liquid appearing as amber with amber color. It has mild odor.
What is POWERZOL™ ZE9640 used for?
Aftermarket - Other