01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
YUBASE 8
Product Form
Substance

Regulatory Identifiers

CAS Number
64742-54-7 Check regulations →
EC Number
265-157-1 Check regulations →
REACH No.
01-2119484627-25

Identified Uses

01 - Manufacture of substance (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 02 - Formulation & (re)packing of substances and mixtures (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 01b - Use of substance as intermediate (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03a - Uses in Coatings: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04a - Use in Cleaning Agents: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 05a - Use in Oil and Gas field drilling and production operations: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 07a - Metal working fluids / rolling oils: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 10a - Use as binders and release agents: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 19 - Rubber production and processing: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 21a - Polymer processing: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12a - Use in fuel: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06a - Lubricants: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 17a - Use in laboratories: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 23 - Mining chemicals: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 22a - Water treatment chemicals: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13a - Functional Fluids: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03b - Uses in Coatings: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04b - Use in Cleaning Agents: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 05b - Use in Oil and Gas field drilling and production operations: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 07b - Metal working fluids / rolling oils: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 10b - Use as binders and release agents: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 11a - Use in Agrochemicals: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 15 - Road and construction applications: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 21b - Polymer processing: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12b - Use in fuel: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06b - Lubricants: Professional (low environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06c - Lubricants: Professional (high environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 17b - Use in laboratories: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 22b - Water treatment chemicals: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 18b - Explosives manufacture & use: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13b - Functional Fluids: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03c - Uses in Coatings: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04c - Use in Cleaning Agents: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 11b - Use in Agrochemicals: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12c - Use in fuel: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06d - Lubricants: Consumer (low environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06e - Lubricants: Consumer (high environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13c - Functional Fluids: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) A15SLb - Use in Road and construction applications: Service life (Professional) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C)

Uses advised against

No additional information available

Manufacturers & Suppliers

REACHLaw Ltd. logo

REACHLaw Ltd.

Vänrikinkuja, 3JK21, 02600 Espoo, Finland

+358 9 412 3055

http://www.reachlaw.fi

S

SK Enmove Co., Ltd

manufacturer

26, Jong-ro, Jongno-gu, 03188, Seoul, South Korea

+82-2-2121-5114

Emergency Contacts

Emergency Contact

112

Vergiftungsinformationszentrale

+43 1 406 43 43

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid

+32 70 245 245

Национален токсикологичен информационен център Многопрофилна болница за активно лечение и спешна медицина "Н.И.Пирогов"

+359 2 9154 233

Centar za kontrolu otrovanja Institut za medicinska istraživanja i medicinu rada

+385 1 234 8342

Κέντρου Δηλητηριάσεων

1401

Operating hours 24 hours / 24 hours, 7 days a week

Toxikologické informační středisko Klinika pracovního lékařství VFN a 1. LF UK

+420 224 919 293

Toxikologické informační středisko Klinika pracovního lékařství VFN a 1. LF UK

+420 224 915 402

Giftlinjen Bispebjerg Hospital

+45 82 12 12 12

Mürgistusteabekeskus Terviseamet

16662

Mürgistusteabekeskus Terviseamet

+372 7943 794

Myrkytystietokeskus

+358 9 471 977

Open 24 hours a day

Myrkytystietokeskus

+358 800 147 111

Open 24 hours a day

Centre Antipoison et de Toxicovigilance de Angers C.H.U

+33 2 41 48 21 21

Giftnotruf der Charité - Universitätsmedizin Berlin CBF, Haus VIII (Wirtschaftgebäude), UG

+49 (0) 30 19240

Poisons Information Centre Children's Hospital P&A Kyriakou

+30 21 07 79 37 77

Nemzeti épegészségügyi Központ Egészségügyi Toxikológiai Tájékoztató Szolgálat

+36 80 20 11 99

Nemzeti épegészségügyi Központ Egészségügyi Toxikológiai Tájékoztató Szolgálat

+36 1 476 6464

National Poisons Information Centre Beaumont Hospital

+353 1 809 2566

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

Centro Antiveleni di Roma CAV Policlinico "A. Gemelli", Dipartimento di Tossicologia Clinica Universita Cattolica del Sacro Cuore

+39 06 305 4343

Toksikoloģijas un sepses klinikas Saindešanās un zāļu informācijas centrs

+371 67 04 24 73

Apsinuodijimų informacijos biuras

+370 5 236 20 52

Apsinuodijimų informacijos biuras

+370 687 53378

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid

+352 8002 5500

FR, NL, EN

Medicines & Poisons Info Office

+356 2545 6508

Nationaal Vergiftigingen Informatie Centrum

+31 30 274 88 88

Szpital Praski p.w. Przemienienia Pańskiego Sp. z o.o.

+48 22 619 66 54

Szpital Praski p.w. Przemienienia Pańskiego Sp. z o.o.

+48 22 619 08 97

Centro de Informação Antivenenos Instituto Nacional de Emergência Médica

+351 800 250 250

TOXAPEL Emergency Clinical Hospital for Children "Grigore Alexandrescu"

+40 2121 06282

TOXAPEL Emergency Clinical Hospital for Children "Grigore Alexandrescu"

+40 2121 06183

Národné toxikologické informačné centrum Univerzitná nemocnica Bratislava, pracovisko Kramáre, Klinika pracovného lekárstva a toxikológie

+421 2 54 77 41 66

Center za klinično toksikologijo in farmakologijo Univerzitetni klinični, Center ljubljana

+386 522 52 83

Servicio de Información Toxicológica Instituto Nacional de Toxicología y Ciencias Forenses, Departamento de Madrid

+34 91 562 04 20

Giftinformationscentralen

112

Giftinformationscentralen

010-456 6700

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic IP 346 < 3%, > 20.5 cSt @ 40 °C EC: 265-157-1 64742-54-7 100% No

Notes

Substance is complex UVCB

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Inhalation at ambient temperature is unlikely because of the low vapour pressure of the substance. Move to well-ventilated area. Check vital signs regularly and act accordingly.

Symptoms: May cause: nasal irritation, respiratory tract irritation.

Skin contact

Remove contaminated, saturated clothing immediately. Wash area with soap and water for 10 to 15 minutes or rinse the skin with 10% dioctyl sulfosuccinate (DS) if available.

Symptoms: Causes mild skin irritation.

Eye contact

Remove contact lenses. Irrigate exposed eyes with 0.9% normal saline if available or water for at least 15 minutes. Irrigate before and after removing the lenses to prevent a carry-over of the substances to the shielded area of the lens.

Symptoms: Mild eye irritation.

Ingestion

IF SWALLOWED: Immediately call a POISON CENTRE or doctor/ physician. Do NOT induce vomiting. If vomiting does occur, have victim lean forward to reduce risk of aspiration.

Symptoms: Incidental oral exposure; aspiration hazard; may be fatal if it enters the airways after swallowing.

Immediate Medical Attention

IF SWALLOWED: Immediately call a POISON CENTRE or doctor/ physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam (Specifically trained personnel only)- Water fog (Specifically trained personnel only)- Dry chemical powder- Carbon dioxide- Other inert gases (subject to regulations)- Sand or earth.

Unsuitable media

Do not use direct water jets on the burning product; they could cause splattering and spread the fire. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.

Firefighter Protection

In case of a large fire or in confined or poorly ventilated spaces wear full fire resistant protective clothing and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop or contain leak at the source if safe to do so. Avoid direct contact with released material. Stay upwind. In case of large spillages, alert occupants in downwind areas. Keep non-involved personnel away from the area of spillage. Alert emergency personnel. Eliminate all ignition sources if safe to do so (e.g. electricity, sparks, fires, flares).

Small spill

in case of small spillages in closed waters (i.e. ports), contain product with floating barriers or other equipment. Collect spilled product by absorbing with specific floating absorbents.

Large spill

Large spillages may be cautiously covered with foam, if available, to limit vapour cloud formation. Do not use direct jets. Large spillages in open waters should be contained with floating barriers or other mechanical means and recovered, only if this is strictly necessary and if fire/explosion risks can be adequately prevented.

Environmental

prevent product from entering sewers, rivers, waterways or other bodies of water.

Cleanup methods

Absorb spilled product with suitable non-combustible materials. Collect free product with suitable means. Transfer collected product and other contaminated materials to suitable containers for recovery or safe disposal.

Materials: suitable non-combustible materials

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Obtain special instructions before use. Ensure that all relevant regulations regarding handling and storage facilities of combustible products are followed. It is recommended to keep away from sparks/open flames/hot surfaces. – No smoking. Use and store only outdoors or in a well-ventilated area. Avoid contact with the product. Avoid release to the environment. Take precautionary measures against static electricity. Avoid splash filling of bulk volumes when handling hot liquid product. Avoid contact with skin. Avoid breathing fume/mist. (If R65 / H304 is applicable): Do not ingest. Prevent the risk of slipping. Use personal protective equipment as required.

Storage

Use and store only outdoors or in a well-ventilated area.

Hygiene

Ensure that proper housekeeping measures are in place. Contaminated materials should not be allowed to accumulate in the workplaces and should never be kept inside the pockets. Keep away from food and beverages. Do not eat, drink or smoke when using this product. Wash the hands thoroughly after handling. Change contaminated clothes at the end of working shift.

Fire prevention

Keep away from sparks/open flames/hot surfaces. – No smoking. Take precautionary measures against static electricity.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure that there is a suitable ventilation system.

Hands

Protective gloves

Eyes

Wear security glasses which protect from splashes. Face shield

Respiratory

In case of inadequate ventilation wear respiratory protection. Do not breathe gas, vapours

Skin/Body

Long sleeved protective clothing

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear, colorless liquid.
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
Slight hydrocarbon odor.
Odor Threshold
Not available
Ph
Not available
Melting Point
Not available
Boiling Point
380 ~560 °C
Flash Point
250 °C (COC)
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
< 0,1 hPa (20°C)
Vapor Density
---
Relative Density
Not available
Bulk Density
---
Density
0.845 g/cc (15°C)
Flammability
Non flammable.
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Water: Calculated water solubility for constituents of this substance range between 2.69E-12 and 2000 mg/L. It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole.
Partition Coefficient
1,99 – 18,02 It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
46 m/s (40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

The product is stable under normal conditions.

Hazardous reactions

Hazardous polymerization will not occur

Avoid

No flames, no sparks. Eliminate all sources of ignition.

Incompatible

Strong acids. Strong oxidizing agents.

Decomposition

No hazardous decomposition products known at room temperature.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Hazardous to the aquatic environment, short-term (acute) : LL50 (96h): >100 mg/L, Pimephales promelas. EL50 (24h): >10000 mg/L, Daphnia magna Hazardous to the aquatic environment, long-term (chronic) : NOELR (14d): >=1000 mg/L, Oncorhynchus mykiss (previous name: Salmo gairdneri). NOEL (21d): 10 mg/L, Daphnia magna Not rapidly degradable

12.2. Persistence and degradability

Distillates (petroleum), hydrotreated heavy paraffinic IP 346 < 3%, > 20.5 cSt @ 40 °C (64742-54-7)

12.2. Persistence and degradability

Distillates (petroleum), hydrotreated heavy paraffinic IP 346 < 3%, > 20.5 cSt @ 40 °C (64742-54-7) | Biodegradation in water | Calculated degradation half-lives for constituents of this substance range between 1.02 - 165496 days. It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole. The range should therefore be treated with caution and not taken out of context. The substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance. | | --- | --- | | Biodegradation in soil | Calculated degradation half-lives for constituents of this substance range between 1.02 - 165496 days. It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole. The range should therefore be treated with caution and not taken out of context. The substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance. |

12.3. Bioaccumulative potential

Distillates (petroleum), hydrotreated heavy paraffinic IP 346 < 3%, > 20.5 cSt @ 40 °C (64742-54-7) BCF - Fish [1] Calculated BCF for constituents of this substance range between 0.4 – 6280 L/kg. It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole. The range should therefore be treated with caution and not taken out of context. The substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance. Partition coefficient n-octanol/water (Log Pow) 1,99 – 18,02 It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole. Bioaccumulative potential Substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance. However, this endpoint has been calculated for representative hydrocarbon structures using the BCFWIN v2.16 model within EPISuite 3.12 as input to the hydrocarbon block method incorporated into the PETRORISK model. The predicted BCFs for hydrocarbons are generally overly conservative since biotransformation is not quantitatively taken into account. Therefore, indirect exposure and resulting risk estimates predicted by PETRORISK are likely to be overestimated.

Mobility in soil

The substance is a hydrocarbon UVCB. Standard tests for this endpoint are intended for single substances and are not appropriate for this complex substance.

The substance is a hydrocarbon UVCB; standard mobility tests are not appropriate for this complex substance.

12.5. Results of PBT and vPvB assessment

This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII

The substance does not meet the PBT or vPvB criteria of REACH regulation, annex XIII.

12.6. Endocrine disrupting properties

Adverse effects on the environment caused by endocrine disrupting properties : The substance is not included in the list established in accordance with Article 59(1) of REACH for having endocrine disrupting properties, or is not identified as having endocrine disrupting properties in accordance with the criteria set out in Commission Delegated Regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605.

The substance is not identified as having endocrine disrupting properties.

12.7. Other adverse effects

No additional information available

No additional information available

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must follow special treatment according to local regulation. Avoid release to the environment. Assure that emissions are compliant with all applicable air pollution control regulations.

Disposal

Refer to manufacturer/supplier for information on recovery/recycling.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Safety, health and environmental regulations/legislation specific for the substance or mixture

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for YUBASE 8?

The signal word is no signal word.

What is the physical form of YUBASE 8?

YUBASE 8 is a liquid appearing as clear, colorless liquid. with colourless. color. It has slight hydrocarbon odor. odor.

What is the solubility of YUBASE 8?

Water: Calculated water solubility for constituents of this substance range between 2.69E-12 and 2000 mg/L. It should be borne in mind that this is the full range of predicted values, and that this may be misleading or unrepresentative of the properties of the UVCB substance as a whole.

What is YUBASE 8 used for?

01 - Manufacture of substance (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 02 - Formulation & (re)packing of substances and mixtures (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 01b - Use of substance as intermediate (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03a - Uses in Coatings: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04a - Use in Cleaning Agents: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 05a - Use in Oil and Gas field drilling and production operations: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 07a - Metal working fluids / rolling oils: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 10a - Use as binders and release agents: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 19 - Rubber production and processing: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 21a - Polymer processing: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12a - Use in fuel: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06a - Lubricants: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 17a - Use in laboratories: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 23 - Mining chemicals: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 22a - Water treatment chemicals: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13a - Functional Fluids: Industrial (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03b - Uses in Coatings: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04b - Use in Cleaning Agents: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 05b - Use in Oil and Gas field drilling and production operations: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 07b - Metal working fluids / rolling oils: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 10b - Use as binders and release agents: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 11a - Use in Agrochemicals: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 15 - Road and construction applications: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 21b - Polymer processing: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12b - Use in fuel: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06b - Lubricants: Professional (low environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06c - Lubricants: Professional (high environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 17b - Use in laboratories: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 22b - Water treatment chemicals: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 18b - Explosives manufacture & use: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13b - Functional Fluids: Professional (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 03c - Uses in Coatings: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 04c - Use in Cleaning Agents: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 11b - Use in Agrochemicals: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 12c - Use in fuel: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06d - Lubricants: Consumer (low environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 06e - Lubricants: Consumer (high environmental release) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) 13c - Functional Fluids: Consumer (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C) A15SLb - Use in Road and construction applications: Service life (Professional) (not classified; H304 only; IP 346 < 3%; > 20.5 cSt @ 40 °C)

What is the melting point of YUBASE 8?

The melting point is Not available and the boiling point is 380 ~560 °C.