NextSDS Logo
Safety Data Sheet EN

601497 R05748A, BULK

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
601497 R05748A, BULK

Regulatory Identifiers

CAS Number
N/A
UFI Code
VU53-S26J-700F-5VK8

Identified Uses

Viscosity Improvers

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

manufacturer

25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR

(33) 02.35.58.14.00

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

Centre antipoisons

(+32) 70 245 245

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This material has no known hazards under applicable laws.

Notes

See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Wash with soap and water. Launder contaminated clothing before reuse.

Eye contact

Any material that contacts the eye should be washed out immediately with water. If easy to do, remove contact lenses.

Immediate Medical Attention

Get medical attention if symptoms occur. Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

Material creates a special hazard because it floats on water. Water may cause splattering. Container may rupture on heating.

Instructions

No data available.

Firefighter Protection

Recommend wearing self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations. Ventilate area if spilled in confined space or other poorly ventilated areas.

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces.

Storage

Store away from incompatible materials. See section 10 for incompatible materials.

Hygiene

Observe good industrial hygiene practices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use material in well ventilated area only. Adequate ventilation should be provided so that exposure limits are not exceeded. Mechanical ventilation or local exhaust ventilation may be required.

Hands

Use nitrile or neoprene gloves. Use good industrial hygiene practices. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

Respiratory

Use disposable dust/mist mask if the recommended exposure limit is exceeded. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Long sleeve shirt is recommended.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Light colored
Colour
Light colored
Colour Intensity
---
Form
liquid
Odor
Mild
Odor Threshold
No data available.
Ph
Not applicable
Melting Point
---
Boiling Point
No data available.
Flash Point
200 °C (Pensky-Martens Closed Cup)
Freezing Point
No data available.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available.
Vapor Pressure
0.0365 PSI (77 °C)
Vapor Density
---
Relative Density
0.840 - 0.880 (15.6 °C)
Bulk Density
---
Density
---
Flammability
No data available.
Upper Explosive Limit
No data available.
Lower Explosive Limit
No data available.
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
---
Partition Coefficient
No data available.
Solubility In Water
Insoluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
No data available.
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
12500 mm2/s (40 °C); 1125 mm2/s (100 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

oxidizing materials

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Ecotoxicity

Fish No data available Aquatic Invertebrates No data available Toxicity to Aquatic Plants No data available Toxicity to soil dwelling organisms No data available Sediment Toxicity No data available Toxicity to Terrestrial Plants No data available Toxicity to Above-Ground Organisms No data available Toxicity to microorganisms No data available

No ecotoxicity data available for any of the tested categories.

12.2 Persistence and Degradability

Biodegradation No data available BOD/COD Ratio No data available

No data available for biodegradation or BOD/COD ratio.

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential Bioconcentration Factor (BCF) No data available Partition Coefficient n-octanol / water (log Kow) No data available

No data available for Bioconcentration Factor (BCF) or Partition Coefficient n-octanol / water (log Kow).

12.4 Mobility:

No data available

No data available

12.5 Results of PBT and vPvB assessment

No data available

12.1 Toxicity

No data available

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

No data available

12.6 Endocrine Disruption:

Product: The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.

12.7 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.

Disposal

Since emptied containers retain product residue, follow label warnings even after container is emptied.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Poison Center Registration Number: PC-340409310

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 601497 R05748A, BULK?

The signal word is no signal word.

What is the physical form of 601497 R05748A, BULK?

601497 R05748A, BULK is a liquid appearing as light colored with light colored color. It has mild odor.

What is 601497 R05748A, BULK used for?

Viscosity Improvers