NextSDS Logo
Safety Data Sheet EN

Precipitation Reagent

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Precipitation Reagent
Product Code
52005

Regulatory Identifiers

CAS Number
N/A

Identified Uses

In vitro diagnostics

Manufacturers & Suppliers

Chromsystems Instruments & Chemicals GmbH logo

Chromsystems Instruments & Chemicals GmbH

manufacturer

Am Haag 12, 82166 Gräfelfing, Germany

+49 89 18930-0

http://www.chromsystems.com

Emergency Contacts

Emergency poison number

+49 89 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Ox. Liq. Cat. 2 H272
Met. Corr. Cat. 1 H290
Skin Corr. Cat. 1A H314
Eye Dam. Cat. 1 H318

GHS Pictograms

GHS03 - Oxidizing

GHS03

GHS05 - Corrosive

GHS05

Hazard Statements

H272 May intensify fire; oxidiser.
H290 May be corrosive to metals.
H314 Causes severe skin burns and eye damage.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P309 + P311 IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
perchloric acid EC: 231-512-4 7601-90-3 10 - 25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. Seek medical treatment.

Skin contact

Wash with polyethylene glycol 400 and then rinse with plenty amounts of water.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. Do not induce vomiting. Call a doctor immediately.

Immediate Medical Attention

Seek medical treatment after inhalation, consult a doctor after eye contact, and call a doctor immediately after swallowing.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

May intensify fire; oxidiser.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Wear protective clothing.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, universal binders

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

When diluting always pour product into water and not vice versa. Open and handle receptacle with care.

Storage

Keep container tightly sealed. Store at +18 to +30 °C.

Fire prevention

The product is not flammable.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. For the permanent contact gloves made of the following materials are suitable: Natural rubber, NR. Recommended thickness of the material: ≥ 0.6 mm. Penetration time: > 480 min. As protection from splashes gloves made of the following materials are suitable: Natural rubber, NR. Recommended thickness of the material: ≥ 0.6 mm. Penetration time: > 480 min.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device only when aerosol or mist is formed.

Skin/Body

Light weight protective clothing

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Fluid
Odor
Odourless
Odor Threshold
---
Ph
1
Melting Point
Undetermined.
Boiling Point
Undetermined.
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Not determined.
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
May be corrosive to metals.
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

May intensify fire; oxidiser. May be corrosive to metals.

Hazardous reactions

Not available.

Avoid

Heating.

Incompatible

Rubber, light metals, metals

Decomposition

Corrosive gases/vapours, Hydrogen chloride (HCl)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: Harmful effect due to pH shift.

12.2 Persistence and degradability

No information available.

12.3 Bioaccumulative potential

No information available.

12.4 Mobility in soil

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT/vPvB assessment is not available as chemical safety assessment is not required/not conducted. PBT: Not applicable. vPvB: Not applicable.

12.6 Endocrine disrupting properties

The product does not contain substances with endocrine disrupting properties.

12.7 Other adverse effects

Additional ecological information: General notes: Must not reach sewage water or drainage ditch undiluted or unneutralised. Water hazard class 1 (German Regulation) (Self-assessment): slightly hazardous for water. Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

The product is classified as slightly hazardous for water (Water hazard class 1) and must be prevented from entering sewage systems, drainage ditches, or groundwater.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with domestic waste. Do not circulate into the main water supply. Product residues are to be disposed of in compliance with Directive 2008/98/EC on Waste and national and local requirements, e.g. in a suitable incineration plant.

Disposal

Leave chemicals in original containers. Transfer small quantities to approved transport containers. Protect collection receptacles and containers from access by unauthorized parties.

Waste Codes

16 05 06* laboratory chemicals, consisting of or containing hazardous substances, including mixtures of laboratory chemicals EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1802
Shipping Name
PERCHLORIC ACID
Transport Class
8
Packing Group
II
ADR

Warning: Corrosive substances.

IMDG

Warning: Corrosive substances.

IATA

Warning: Corrosive substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No further relevant information available.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Precipitation Reagent?

The signal word is danger.

What is the physical form of Precipitation Reagent?

Precipitation Reagent is a liquid with colourless color. It has odourless odor.

What is Precipitation Reagent used for?

In vitro diagnostics

What are the hazard statements for Precipitation Reagent?

This substance has 3 hazard statements:

  • H272: May intensify fire; oxidiser.
  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.

What is the melting point of Precipitation Reagent?

The melting point is Undetermined. and the boiling point is Undetermined..