01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
pH Electrode Storage Reagent
Product Code
2657364

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Electrode storage solution

Uses advised against

No information available

Manufacturers & Suppliers

H

Hach Sales & Service LP.

national supplier

3020 Gore Road, London, Ontario N5V 4T7 Canada

1-800-665-7635

H

Hach Company

manufacturer

P.O. Box 389 Loveland, CO 80539 USA

+1(970) 669-3050

Emergency Contacts

Chemtrec

1-800-424-9300

CANUTEC

613-992-4624

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sodium phosphate dibasic 7558-79-4 1 - 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air.

Skin contact

Wash skin with soap and water.

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a physician.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

Caution: Use of water spray when fighting fire may be inefficient.

Specific hazards

No information available.

Firefighter Protection

Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

See Section 12 for additional ecological information.

Cleanup methods

Pick up and transfer to properly labeled containers.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Showers Eyewash stations Ventilation systems.

Hands

Wear suitable gloves.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.

Skin/Body

No special protective equipment required.

Environmental

Local authorities should be advised if significant spillages cannot be contained. Do not allow into any sewer, on the ground or into any body of water.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
powder
Colour
white
Colour Intensity
---
Form
powder
Odor
Odorless
Odor Threshold
No data available
Ph
~ 7
Melting Point
> 360 °C / 680 °F
Boiling Point
No data available
Flash Point
Not applicable
Freezing Point
- 360 C / 680 F
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable
Vapor Pressure
Not applicable
Vapor Density
Not applicable
Relative Density
1.98
Bulk Density
No information available
Density
---
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
log Kow~ 0
Solubility In Water
> 1000 mg/L
Solubility In Fat
---
Molecular Weight
No data available
Voc Content
Not applicable
Metal Corrosion
Not applicable Not applicable
Dynamic Viscosity
Not applicable
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Not applicable.

Hazardous reactions

None under normal processing.

Incompatible

Strong oxidizing agents, strong acids, and strong bases.

Decomposition

Phosphorus oxides. Sodium monoxide. Potassium oxide. Chlorides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.

Disposal

Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for pH Electrode Storage Reagent?

The signal word is no signal word.

What is the physical form of pH Electrode Storage Reagent?

pH Electrode Storage Reagent is a solid appearing as powder with white color. It has odorless odor.