NextSDS Logo
Safety Data Sheet EN

HYDROTINT GREEN 5584 V2

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HYDROTINT GREEN 5584 V2

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

C

Chat Investments, Ltd T/a DVM Pigments

manufacturer

DVM Pigments & Additives Ratcliffe Street BB3 2BZ Darwen, Lancashire

+441257278995

Emergency Contacts

CHEMTREC

(800) 424-9300

CHEMTREC International

(703) 527-3887

Industrial Health/Spill Emergency

(706) 277-1300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2,2'-oxydiethanol 111-46-6 1 - 10% No
2,2',2''-(hexahydro-1,3,5-triazine-1,3,5-triyl)triethanol 4719-04-4 0.1 - 0.25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

If on skin, rinse well with water.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Instructions

Standard procedure for chemical fires.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapors/dust. Avoid exposure - obtain special instructions before use. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations. Persons susceptible to skin sensitization problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used.

Storage

Keep container tightly closed in a dry and well-ventilated place. Do not freeze.

Hygiene

Wash hands before breaks and at the end of workday.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Eye wash bottle with pure water; Tightly fitting safety goggles

Respiratory

No personal respiratory protective equipment normally required.

Skin/Body

Impervious clothing; Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
paste
Physical State Data
solid
State Under Standard Conditions
---
Appearance
paste
Colour
green
Colour Intensity
---
Form
paste
Odor
mild
Odor Threshold
---
Ph
7.5 - 9.5
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
No data available
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
No data available
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and applied as directed.

Reactivity

No decomposition if stored and applied as directed.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

No data available

Incompatible

Not applicable

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.5 Results of PBT and vPvB assessment

Assessment : This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be PBT or vPvB at levels of 0.1% or higher.

12.6 Other adverse effects

Endocrine disrupting potential : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

12.1 Toxicity

2,2'-oxydiethanol: Toxicity to fish : LC50 (Carp (Leuciscus idus melanotus)): > 10,000 mg/l Exposure time: 48 h LC50 (Pimephales promelas (fathead minnow)): 75,200 mg/l Exposure time: 96 h Analytical monitoring: Analytical monitoring: yes Method: flow-through test GLP: no Toxicity to daphnia and other aquatic invertebrates : EC50 (Daphnia magna (Water flea)): > 10,000 mg/l Exposure time: 24 h Analytical monitoring: Analytical monitoring: no Method: static test GLP: no LC50 (Daphnia magna (Water flea)): 10,000,000 µg/l Exposure time: 24 h Toxicity to fish (Chronic toxicity) : LC50: > 1,500 mg/l Exposure time: 28 d Species: Menidia peninsulae Analytical monitoring: Analytical monitoring: yes Method: flow-through test Toxicity to daphnia and other aquatic invertebrates (Chronic toxicity) : EC50: 33,911 mg/l Exposure time: 21 d Species: Daphnia magna (Water flea) Analytical monitoring: Analytical monitoring: no Method: static test GLP: No data available

12.1 Toxicity

2,2',2''-(hexahydro-1,3,5-triazine-1,3,5-triyl)triethanol: Toxicity to fish : LC50 (Danio rerio (zebra fish)): 16.07 mg/l Exposure time: 96 h Analytical monitoring: Analytical monitoring: yes Method: static test GLP: yes Toxicity to daphnia and other aquatic invertebrates : EC50 (Daphnia magna (Water flea)): 11.9 mg/l Exposure time: 48 h Analytical monitoring: Analytical monitoring: yes Method: static test GLP: yes

12.2 Persistence and degradability

2,2'-oxydiethanol: Biodegradability : Concentration: 100 mg/l Biodegradation: 25 - 92 % Exposure time: 28 d GLP: no Biodegradation: 90 - 100 % Exposure time: 10 d GLP: yes Biodegradation: 70 - 80 % Exposure time: 28 d GLP: no Biodegradation: 90 - 100 % Exposure time: 20 d GLP: yes Biodegradation: 90 - 100 % Exposure time: 28 d GLP: no Biodegradation: 90 - 100 % Exposure time: 28 d GLP: yes

12.2 Persistence and degradability

2,2',2''-(hexahydro-1,3,5-triazine-1,3,5-triyl)triethanol: Biodegradability : Biodegradation: 90 - 100 % Exposure time: 8 d GLP: yes Concentration: 100 mg/l Biodegradation: 89 - 95 % Exposure time: 10 d GLP: No data available

12.3 Bioaccumulative potential

Components:

12.3 Bioaccumulative potential

2,2'-oxydiethanol: Bioaccumulation : Species: Leuciscus idus (Golden orfe) Exposure time: 3 d Bioconcentration factor (BCF): 100 Partition coefficient: n-octanol/water : log Pow: -1.47
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a licensed waste management company.

Disposal

Do not dispose of waste into sewer. Do not contaminate ponds, waterways or ditches with chemical or used container.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Relevant EU provisions transposed through retained EU law

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HYDROTINT GREEN 5584 V2?

The signal word is no signal word.

What is the physical form of HYDROTINT GREEN 5584 V2?

HYDROTINT GREEN 5584 V2 is a paste appearing as paste with green color. It has mild odor.

What is the melting point of HYDROTINT GREEN 5584 V2?

The melting point is No data available and the boiling point is No data available.