Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Forming gas H5, hydrogen in nitrogen mixture
- Product Code
- D-H2-N2-001
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions. Perform risk assessment prior to use.
Uses advised against
Attention: These products must not be applied to humans or animals unless they are expressly designated as medical or medicinal gases!. Uses other than those listed above are not supported, contact your supplier for more information on other uses.
Manufacturers & Suppliers
Messer Industriegase GmbH
manufacturer
Messer-Platz 1, D-65812 Bad Soden am Taunus, Germany
+49 (0) 6196 7760-200
http://www.messer.de
Emergency Contacts
Messer Produktionsgesellschaft mbH Salzgitter
+49 (0) 5341 21-9333
erreichbar Montags 0:00 bis Sonntags 24:00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Adverse effects not expected from this product.
Adverse effects not expected from this product.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
Call a doctor.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or fog. Shutting off the source of the gas is the preferred method of control. The material is not flammable. In case of environmental fire: Use suitable fire extinguishing agent. Product does not burn, use fire control measures appropriate for the surrounding fire.
Do not use water jet to extinguish.
Exposure to fire may cause containers to rupture. Exposure to fire may cause containers to rupture/explode.
Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.
Firefighter Protection
In confined space use self-contained breathing apparatus. Standard protective clothing and equipment (Self Contained Breathing Apparatus) for fire fighters. Standard EN 469 - Protective clothing for firefighters. Standard EN 659 - Protective gloves for firefighters. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Act in accordance with local emergency plan. Try to stop release. Evacuate area. Ensure adequate air ventilation. Stay upwind.
Try to stop release.
Related Products
Similar products with comparable safety profiles
Mixture 30% H2 in N2
UFI: CQ42-D0UD-W009-T5E2
Mixture 10% H2 in N2
UFI: F684-V7PN-200F-3NDA
Mixture 1% H2 in N2
---
Hydrogen ( 0.0001% - 5.70% ) in Nitrogen
---
Mixture 2% H2, 20.9% O2 in N2
---
Mixture 80 PPM C3H8 in N2
---
Oxidizing Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen
---
Mixture 4% CO in N2
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularly) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Avoid suck back of water, acid and alkalis. Do not breathe gas. Avoid release of product into work area. Safe handling of the gas receptacle: Do not allow backfeed into the container. Protect containers from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps, when provided, in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the content of the container. Suck back of water into the container must be prevented. Open valve slowly to avoid pressure shock.
Containers should be stored in the vertical position and properly secured to prevent them from falling over. Keep container below 50°C in a well ventilated place. Store containers in location free from fire risk and away from sources of heat and ignition. Containers should not be stored in conditions likely to encourage corrosion.
The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product. Do not breathe gas.
Do not smoke while handling product. Never use direct flame or electrical heating devices to raise the pressure of a container.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularly checked for leakages. Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.
Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.
Standard EN 166 - Personal eye-protection - specifications. Standard EN ISO 16321-1 - Eye and face protection for occupational use Part 1: General requirements.
Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Can form explosive mixture with air. May react violently with oxidants.
None.
Keep away from heat/sparks/open flames/hot surfaces. – No smoking. Avoid moisture in installation systems.
For additional information on compatibility refer to ISO 11114.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
No data available for toxicity assessment.
12.2. Persistence and degradability
No data available.
12.3. Bioaccumulative potential
No ecological damage caused by this product.
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
Not classified as PBT or vPvB.
12.6. Endocrine disrupting properties
The substance/mixture has no endocrine disrupting properties.
12.7. Other adverse effects
The substance is not classified as PMT or vPvM, has no effect on the ozone layer, and contains greenhouse gas(es).
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Do not discharge into any place where its accumulation could be dangerous. May be vented to atmosphere in a well ventilated place.
Return unused product in original container to supplier.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1956
- Shipping Name
- COMPRESSED GAS, N.O.S. (Nitrogen, hydrogen)
- Transport Class
- 2.2
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Forming gas H5, hydrogen in nitrogen mixture?
The signal word is warning.
What is the physical form of Forming gas H5, hydrogen in nitrogen mixture?
Forming gas H5, hydrogen in nitrogen mixture is a gas. with colourless. color. It has odourless. odor.
What is Forming gas H5, hydrogen in nitrogen mixture used for?
Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions. Perform risk assessment prior to use.
What are the hazard statements for Forming gas H5, hydrogen in nitrogen mixture?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of Forming gas H5, hydrogen in nitrogen mixture?
The melting point is Not applicable for gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: hydrogen -253 °C.