Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dimethyloxaloylglycine
- Product Code
- J67077
Regulatory Identifiers
- CAS Number
- 89464-63-1 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher (Kandel) GmbH
manufacturer
Erlenbachweg 2, 76870 Kandel, Germany
+49 (0) 721 84007 280
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
https://www.fishersci.ch/ch/en/customer-help-support/forms/email-us.html
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
24h
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Glycine, N-(2-methoxy-2-oxoacetyl)-, methyl ester | 89464-63-1 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required.
Should not be released into the environment. See Section 12 for additional Ecological Information.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation. Avoid dust formation.
Store in freezer.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove materials: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374 (minimum requirement). Inspect gloves before use. Observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Handle gloves with care avoiding skin contamination.
Wear safety glasses with side shields (or goggles) (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous Polymerization: No information available.
Incompatible products. Excess heat.
None known.
Carbon monoxide (CO). Carbon dioxide (CO₂). Nitrogen oxides (NOx).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The substance is not known to be hazardous to the environment or non-degradable in wastewater treatment plants.
12.2. Persistence and degradability
No information available
12.3. Bioaccumulative potential
No information available
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
No data available for assessment.
12.6. Endocrine disrupting
This product does not contain any known or suspected endocrine disruptors
12.7. Other adverse effects
This product does not contain any known or suspected substance for Persistent Organic Pollutant or Ozone Depletion Potential.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.
Waste is classified as hazardous.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Not applicable for REACH authorization/restrictions.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dimethyloxaloylglycine?
The signal word is warning.
What is the physical form of Dimethyloxaloylglycine?
Dimethyloxaloylglycine is a solid appearing as off-white . It has no information available odor.
What is Dimethyloxaloylglycine used for?
Laboratory chemicals.
What are the hazard statements for Dimethyloxaloylglycine?
This substance has 1 hazard statement:
- H302: Harmful if swallowed
What is the melting point of Dimethyloxaloylglycine?
The melting point is No data available and the boiling point is No information available.