Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Phosphate buffered saline pH 7.4, contains BSA, powder pack
- Product Code
- 20-7466
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Uses advised against
Any use not specified above.
Manufacturers & Suppliers
Severn Biotech Ltd.
manufacturer
Unit 2, Park Lane, Kidderminster, Worcestershire. DY11 6TJ, UK
0044 1562 825286
Emergency Contacts
NHS 111
111
NHS 24
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions. The ingredients are not classified as hazardous or are below disclosure limits.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium chloride EC: 231-598-3 | 7647-14-5 | 25 - 50% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately rinse with water. If skin irritation continues, consult a doctor.
Check for and remove any contact lenses. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.
Water with full jet
As with most organic solids, fire is possible at elevated temperatures or by contact with an ignition source. Fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard.
Firefighter Protection
Do not inhale explosion gases or combustion gases. Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to penetrate the ground/soil. Do not allow to enter sewers/ surface or ground water.
Pick up mechanically.
Materials: suitable receptacles
Related Products
Similar products with comparable safety profiles
Phosphate buffered saline
---
Phosphate buffered saline
---
Dulbecco's Phosphate Buffered Saline
---
BDH Buffer Solution pH 7.0 (Phosphate)
---
Phosphate Buffer
---
Sodium phosphate, dibasic dihydrate, 98%, extra pure
CAS: 10028-24-7
Sodium phosphate, tribasic, anhydrous
CAS: 7601-54-9
Sodium phosphate, tribasic, anhydrous
CAS: 7601-54-9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent formation of dust.
Store in cool, dry conditions in well sealed receptacles.
There is a risk of a dust explosion if the following conditions are met: - The substance is present in very finely distributed form (powder, dust). - The substance is whirled up in sufficient quantity in the air. - An ignition source is present (flame, spark, electrostatic discharge, etc.)
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Protective gloves. Use gloves tested and approved under appropriate government standards such as NIOSH (US) or EN374 (EU). The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Use suitable respiratory protective device in case of insufficient ventilation.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
There is a risk of a dust explosion if the following conditions are met: The substance is given in very finely distributed form (powder, dust). The substance is whirled up in sufficient quantity in the air. An ignition source is present (flame, spark, electrostatic discharge, etc.)
The substance is given in very finely distributed form (powder, dust). The substance is whirled up in sufficient quantity in the air. An ignition source is present (flame, spark, electrostatic discharge, etc.)
Strong oxidising agents.
Carbon monoxide and carbon dioxide, Phosphorus oxides (e.g. P.O.), Chlorine compounds, Toxic metal oxide smoke
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Minimise waste; Reuse if not contaminated; Recycle, if possible; or Safe disposal (if all else fails). Small amounts may be diluted with plenty of water and washed away. Dispose of bigger amounts in accordance with Local Authority requirements.
Contact waste processors for recycling information.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Phosphate buffered saline pH 7.4, contains BSA, powder pack?
The signal word is no signal word.
What is the physical form of Phosphate buffered saline pH 7.4, contains BSA, powder pack?
Phosphate buffered saline pH 7.4, contains BSA, powder pack is a solid with whitish color. It has odourless odor.
What is Phosphate buffered saline pH 7.4, contains BSA, powder pack used for?
Laboratory chemicals
What is the melting point of Phosphate buffered saline pH 7.4, contains BSA, powder pack?
The melting point is Undetermined. and the boiling point is Undetermined..