Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Klercide 70/30 IPA
- Product Form
- AL - Any other liquid
- Product Code
- 116179E
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Surface disinfectant. Manual process Surface disinfectant. Spray and rinse manual process
Uses advised against
Reserved for industrial and professional use.
Manufacturers & Suppliers
Ecolab Ltd.
manufacturer
PO Box 11; Winnington Avenue Northwich, Cheshire, United Kingdom CW8 4DX
+44 (0)1606 74488
Emergency Contacts
Emergency Contact
+441618841235
Trans-European
+32-(0)3-575-5555
Poison Information Centre
0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isopropyl Alcohol EC: 200-661-7 | 67-63-0 | 50 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTRE or a doctor.
Take off all contaminated clothing and wash it before reuse. Wash skin with water. If skin irritation occurs: Get medical advice.
Rinse with water. Remove contact lenses, if present and easy to do. Continue rinsing for 5 minutes. Call a POISON CENTRE or a doctor.
Rinse mouth. Give something to drink, if exposed person is able to swallow. Do NOT induce vomiting. Call a POISON CENTRE or a doctor.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Fire Hazard. Keep away from heat and sources of ignition. Flash back possible over considerable distance. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Firefighter Protection
Use personal protective equipment. In the event of fire and/or explosion do not breathe fumes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove all sources of ignition. Ensure clean-up is conducted by trained personnel only. Refer to protective measures listed in sections 7 and 8.
For large spills, dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.
Do not allow contact with soil, surface or ground water.
Collect spillage. Contain spillage, and then collect with non-combustible absorbent material. Flush away traces with water.
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Klerwipe 70/30 IPA
---
Klerwipe 70/30 IPA
---
Premier-WFI Klercide 70/30 Sterile IPA, Premier-WFI Klercide 70/30, Sterile IPA Kleralcohol 70/30 IPA
---
Klercide Neutral Detergent
---
Klercide Low Residue Quat
---
Klercide Low Residue Quat
---
Premier Klercide-CR Sterile Biocide Y Unit Dose Concentrate, Klercide-CR Biocide Y Unit Dose Concentrate
---
KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Use only with adequate ventilation. Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Wash hands thoroughly after handling. Open drum carefully as content may be under pressure. Do not breathe spray, vapour. In case of mechanical malfunction, or if in contact with unknown dilution of product, wear full Personal Protective Equipment (PPE). Only for mopping use: respiratory protection equipment (RPE) of protection factor of 10 should be worn during the application.
Keep in a cool, well-ventilated place. Keep container tightly closed. Store in suitable labeled containers.
Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling.
Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Effective exhaust ventilation system. Maintain air concentrations below occupational exposure standards.
No special protective equipment required.
Safety glasses with side-shields
None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, (EU) 2016/425), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.
No special protective equipment required.
Consider the provision of containment around storage vessels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No dangerous reaction known under conditions of normal use.
Heat, flames and sparks.
None known.
Depending on combustion properties, decomposition products may include following materials: Carbon oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
This product has no known ecotoxicological effects.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
no data available
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of contents/container in accordance with local regulations. Dispose of wastes in an approved waste disposal facility.
Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of contents/container in accordance with local regulations. Dispose of wastes in an approved waste disposal facility.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1219
- Shipping Name
- ISOPROPANOL
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Klercide 70/30 IPA?
The signal word is danger.
What is the physical form of Klercide 70/30 IPA?
Klercide 70/30 IPA is a liquid appearing as liquid with clear, colourless color. It has alcohol-like odor.
What is the solubility of Klercide 70/30 IPA?
Not applicable and/or not determined for the mixture
What is Klercide 70/30 IPA used for?
Surface disinfectant. Manual process Surface disinfectant. Spray and rinse manual process
What are the hazard statements for Klercide 70/30 IPA?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Klercide 70/30 IPA?
The melting point is Not applicable and/or not determined for the mixture and the boiling point is > 35 °C.