NextSDS Logo
Safety Data Sheet EN

NeoMass CAH kit

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
NeoMass CAH kit
Product Code
7150022, 3467702, 3467703, 3467704, 3467705, 3467706, 3467708, 3467709

Regulatory Identifiers

CAS Number
N/A

Identified Uses

NeoMass CAH kit is intended for the quantitative determination of androstendione (ANDR), 11-deoxycortisol (11-DOC), 21-deoxycortisol (21-DOC), cortisol (CORT), 17-hydroxyprogesterone (17-OHP) & 21-hydroxyprogesterone (21-OHP) from whole blood dried on filter paper as a second-tier test for screening of Congenital Adrenal Hyperplasia (CAH) in newborns.

Manufacturers & Suppliers

Labsystems Diagnostics logo

Labsystems Diagnostics

Tiiiltie 3, FIN-01720 Vantaa

+358-20-155 7523

http://www.labsystemsdx.com

Emergency Contacts

Emergency Contact

112

Poison information center

09-471997

Poison information center

09-4711

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

H302
H312
H332
H371
H225
H301
H311
H370
H319
H226

GHS Pictograms

GHS02 - Flammable

GHS02

GHS06 - Acute toxicity

GHS06

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor
H226 Flammable liquid and vapor
H302 + H312 + H332 Harmful if swallowed, in contact with skin or if inhaled
H311 + H331 Toxic in contact with skin or if inhaled
H319 Causes serious eye irritation
H351 Suspected of causing cancer
H360 May damage fertility or the unborn child
H362 May cause harm to breast-fed children
H370 Causes damage to organs
H371 May causes damage to organs
H373 May causes damage to organs

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking
P243 Take precautionary measures against static discharge
P280 Wear eye protection, face protection, protective clothing, protective gloves
P301 + P310 If swallowed immediately call a POISON CENTER or doctor/physician.
P301 + P312 Call a POISON CENTER or doctor if swallowed
P302 + P352 Wash with plenty of soap and water
P304 + P340 Remove victim to fresh air and keep at rest in a position comfortable for breathing (if inhaled)
P305 + P351 + P338 If contact in eyes rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up
P501 Dispose of contents/container in accordance with local/regional/national/international regulation.
Call a POISON CENTER or doctor/physician

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Methanol 67-56-1 65% Yes
Acetonitrile 75-05-8 70% Yes
Formic acid --- 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin contact

Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.

Eye contact

Flush eyes with water as a precaution

Ingestion

Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Immediate Medical Attention

Take victim immediately to hospital.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, dry chemical, carbon dioxide or appropriate foam to extinguish fire.

Specific hazards

Carbon oxides

Instructions

Use firefighting measures that suit the environment.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear respiratory protection. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

collect with an electrically protected vacuum cleaner or by wet-brushing and place it in a container for disposal according to local regulations.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. Keep away from sources of ignition - No smoking. Take measures to prevent the build-up of electrostatic charge.

Storage

Keep the reagents stored in a cold place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Fire prevention

Keep away from sources of ignition - No smoking. Take measures to prevent the build-up of electrostatic charge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Safety gloves recommended

Eyes

Protective goggles recommended

Skin/Body

Lab coat recommended

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
---
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not available
Ph
Not available
Melting Point
Acetonitrile -45°C / Methanol -94°C
Boiling Point
Acetonitrile 82°C / Methanol 65°C
Flash Point
Acetonitrile 14°C / Methanol 27°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
>1 [Air = 1]
Relative Density
0.783 to 0.7914
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
16 to 36%
Lower Explosive Limit
4.4 to 6%
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Soluble in the following materials: cold water and hot water
Partition Coefficient
Not available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld,braze, solder, drill, grind or expose containers to heat or sources of ignition. Do not allow vapor to accumulate in low or confined areas.

Incompatible

oxidizing materials, reducing materials, metals, acids and alkalis

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

## 12.1 Toxicity

12.2 Persistence and degradability

## 12.2 Persistence and degradability

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

12.4 Mobility in soil

## 12.4 Mobility in soil

12.5 Results of PBT and vPvB assessment

## 12.5 Results of PBT and vPvB assessment

12.6 Other adverse effects

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

The disposal should be carried out according to the existing local laws and the existing local regulation governing water pollution.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1230, 1648
Shipping Name
Methanol, Acetonitrile
Transport Class
3 (6.1), 3
Packing Group
II
ADR

Warning: Flammable liquids

IMDG

Warning: Flammable liquids

IATA

Warning: Flammable liquids

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for NeoMass CAH kit?

The signal word is warning.

What is the physical form of NeoMass CAH kit?

NeoMass CAH kit is a liquid appearing as liquid . It has characteristic odor.

What is the solubility of NeoMass CAH kit?

Soluble in the following materials: cold water and hot water

What is NeoMass CAH kit used for?

NeoMass CAH kit is intended for the quantitative determination of androstendione (ANDR), 11-deoxycortisol (11-DOC), 21-deoxycortisol (21-DOC), cortisol (CORT), 17-hydroxyprogesterone (17-OHP) & 21-hydroxyprogesterone (21-OHP) from whole blood dried on filter paper as a second-tier test for screening of Congenital Adrenal Hyperplasia (CAH) in newborns.

What are the hazard statements for NeoMass CAH kit?

This substance has 11 hazard statements:

  • H225: Highly flammable liquid and vapor
  • H226: Flammable liquid and vapor
  • H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled
  • H311 + H331: Toxic in contact with skin or if inhaled
  • H319: Causes serious eye irritation
  • H351: Suspected of causing cancer
  • H360: May damage fertility or the unborn child
  • H362: May cause harm to breast-fed children
  • H370: Causes damage to organs
  • H371: May causes damage to organs
  • H373: May causes damage to organs

What is the melting point of NeoMass CAH kit?

The melting point is Acetonitrile -45°C / Methanol -94°C and the boiling point is Acetonitrile 82°C / Methanol 65°C.