Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HPE buffer
- Product Code
- M1940, M9161
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For research use only
Uses advised against
Not suitable for in vitro diagnostic use.
Manufacturers & Suppliers
Sanquin
national supplier
Plesmanlaan 125, 1066 CX Amsterdam, The Netherlands
+31 20 512 3599
http://www.sanquin.org/reagents
Emergency Contacts
Emergency Contact
+31 20 512 3599
Mon-Fri 09:00 - 17:00, (CET)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The product does not contain any (other) ingredients which are classified according to present knowledge of the supplier and contribute to the classification of the product and hence require reporting in this section.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| tetrasodium ethylenediam-inetetraacetate EC: 200-573-9 | 64-02-8 | 1.9% | Yes |
Notes
All the percentages given are percentages by weight unless stated otherwise.
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. In case of respiratory tract irritation, consult a physician.
Wash with plenty of soap and water. If skin irritation or rash occurs: Get medical advice/attention.
Irrigate copiously with clean, fresh water for at least 15 minutes, holding the eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing. Call a POISON CENTER/doctor.
Rinse mouth with water (only if the person is conscious). Call a POISON CENTER or doctor if you feel unwell.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. If breathing is irregular or stopped, immediately seek medical assistance. In case of respiratory tract irritation, consult a physician. If skin irritation or rash occurs: Get medical advice/attention. Call a POISON CENTER/doctor for eye contact and ingestion.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry extinguishing powder; Carbon dioxide (CO2)
Water jet.
During fire hazardous fumes/smoke could be produced.
Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Self-contained breathing apparatus (EN 133). Standard protective clothing for firefighters.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety. Ventilate affected area.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Wipe up with absorbent material (e.g. cloth, fleece).
Materials: cloth, fleece
Related Products
Similar products with comparable safety profiles
Homogenization Buffer
---
Extraction Buffer
---
pH Buffer 6.00
UFI: NX80-T0JN-8007-MNAM
2-[4-(2-Hydroxyethyl)-1-piperazinyl]-ethanesulfonic acid Buffer substance HEPES EMPROVE® EXPERT
CAS: 7365-45-9
Wash Buffer
---
pH 4.01 Buffer Solution
---
pH 4.01 Buffer Solution
---
CCB Buffer
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use local and general ventilation. Use only in well-ventilated areas.
Protect against external exposure, such as High temperatures. Frost. UV-radiation/sunlight.
Wash hands after use. Do not eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas. Never keep food or drink in the vicinity of chemicals. Never place chemicals in containers that are normally used for food or drink. Keep away from food, drink and animal feedingstuffs.
measures to prevent fire
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
General ventilation.
Wear suitable gloves. Check leak-tightness/impermeability prior to use. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Chemical protection gloves are suitable, which are tested according to EN 374. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Type of material: PVC: polyvinyl chloride, CR: chloroprene (chlorobutadiene) rubber, Nitrile rubber. Material thickness: Use gloves with a minimum material thickness: ≥ 0,38 mm. Breakthrough times of the glove material: Use gloves with a minimum breakthrough times of the glove material: >480 minutes (permeation: level 6).
Use safety goggle with side protection (EN 166).
In case of inadequate ventilation wear respiratory protection. Type: ABEK-P2 (combined filters against gases, vapours and particles, colour code: Brown/Grey/Yellow/Green/White).
Protective clothing (EN 340 & EN ISO 13688).
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
See below 'Conditions to avoid'.
This material is not reactive under normal ambient conditions.
No known hazardous reactions.
There are no specific conditions known which have to be avoided.
Oxidisers.
Reasonably anticipated hazardous decomposition products produced as a result of use, storage, spill and heating are not known. Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Shall not be classified as hazardous to the aquatic environment.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
Data are not available.
12.3 Bioaccumulative potential
Data are not available.
12.4 Mobility in soil
Data are not available.
12.5 Results of PBT and vPvB assessment
The mixture does not contain any substances that are assessed to be a PBT or a vPvB.
12.6 Other adverse effects
Data are not available. None of the ingredients are listed as endocrine disruptors.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Relevant provisions of the European Union (EU)
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HPE buffer?
The signal word is warning.
What is the physical form of HPE buffer?
HPE buffer is a liquid with light yellow color. It has characteristic odor.
What is the solubility of HPE buffer?
not determined
What is HPE buffer used for?
For research use only
What are the hazard statements for HPE buffer?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of HPE buffer?
The melting point is not determined and the boiling point is 100 °C.