Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI
- Product Form
- Mixture
- Product Code
- H-1800
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Manufacturers & Suppliers
Vector Laboratories, Inc.
manufacturer
6737 Mowry Ave Newark, CA 94560 U.S.A
(650) 697-3600
Emergency Contacts
Emergency Contact
(800) 227-6666
Emergency Contact
+1 (650) 697-3600
7:15 AM - 5:00 PM PST
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol, ethyl alcohol | 64-17-5 | 5% | No |
Trace ingredients (if any) are present in < 1% concentration, (< 0.1% for potential carcinogens, mutagen, and reproductive toxicant, respiratory tract and skin sensitizers in addition to oral/ inhalation acute toxicant in category 1 and 2). None of the trace ingredients contribute significant additional hazards at the concentrations that may be present in this product.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Wash skin with plenty of water.
Rinse eyes with water as a precaution.
Call a poison center/doctor/physician if you feel unwell.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Dry powder. Foam. Carbon dioxide.
Combustible liquid.
Firefighter Protection
Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ventilate spillage area. No open flames, no sparks, and no smoking.
Avoid release to the environment.
Take up liquid spill into absorbent material.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Wear personal protective equipment.
Store in a well-ventilated place. Keep cool.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
Protective gloves
Safety glasses
In case of insufficient ventilation, wear suitable respiratory equipment
Wear suitable protective clothing
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
The product is non-reactive under normal conditions of use, storage and transport.
No dangerous reactions known under normal conditions of use.
Avoid contact with hot surfaces. Heat. No flames, no sparks. Eliminate all sources of ignition.
No additional information available
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The product is not considered harmful to aquatic organisms or to cause long-term adverse effects in the environment.
12.1. Toxicity
12.3. Bioaccumulative potential
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/container in accordance with licensed collector's sorting instructions.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- NA1993
- Shipping Name
- Combustible liquid, n.o.s. (CONTAINS : ethanol, ethyl alcohol)
- Transport Class
- Combustible liquid
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
All components of this product are present and listed as Active on the United States Environmental Protection Agency Toxic Substances Control Act (TSCA) inventory
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI?
The signal word is warning.
What is the physical form of VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI?
VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI is a liquid appearing as clear with pale yellow color. It has alcohol odor odor.
What is the solubility of VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI?
No data available
What is VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI used for?
Laboratory chemicals
What are the hazard statements for VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI?
This substance has 1 hazard statement:
- H227: Combustible liquid
What is the melting point of VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI?
The melting point is Not applicable and the boiling point is 143 °F (estimated value).