Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- VECTASHIELD® Antifade Mounting Medium with DAPI
- Product Form
- Mixture
- Product Code
- H-1200
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals
Manufacturers & Suppliers
Vector Laboratories, Inc.
manufacturer
6737 Mowry Ave, Newark, CA 94560, U.S.A
(650) 697-3600
Emergency Contacts
Emergency Contact
(800) 227-6666
Emergency Contact
+1 (650) 697-3600
7:15 AM - 5:00 PM PST
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This mixture does not contain any substances to be mentioned according to the criteria for section 3.2 of HCS
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Symptoms: None under normal conditions.
Wash skin with plenty of water.
Symptoms: None under normal conditions.
Rinse eyes with water as a precaution.
Symptoms: None under normal conditions.
Call a poison center/doctor/physician if you feel unwell.
Symptoms: None under normal conditions.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Dry powder. Foam. Carbon dioxide.
Do not use a heavy water stream.
No fire hazard. No direct explosion hazard.
Fight fire from safe distance and protected location. Do not enter fire area without proper protective equipment, including respiratory protection.
Firefighter Protection
Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if safe to do so. Ventilate spillage area. Evacuate unnecessary personnel.
Notify authorities if product enters sewers or public waters.
Absorb spillage to prevent material-damage.
Materials: absorbent material
Related Products
Similar products with comparable safety profiles
VECTASHIELD Vibrance® Antifade Mounting Medium with DAPI
---
VECTASHIELD® Mounting Medium
---
Fluorescence Mounting Medium
---
Fluorescence Mounting Medium
---
Fluorescence Mounting Medium
---
VectaMount® AQ Aqueous Mounting Medium
---
Dako Mounting Medium
---
Dako Mounting Medium
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation of the work station. Wear personal protective equipment.
Keep cool. Protect from sunlight.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
Protective gloves
Safety glasses
In case of insufficient ventilation, wear suitable respiratory equipment
Wear suitable protective clothing
Avoid release to the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
The product is non-reactive under normal conditions of use, storage and transport.
No dangerous reactions known under normal conditions of use.
None under recommended storage and handling conditions (see section 7).
No additional information available
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The product is not considered harmful to aquatic organisms or to cause long-term adverse effects in the environment.
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Other adverse effects
No additional information available
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/container in accordance with licensed collector's sorting instructions.
Disposal must be done according to official regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for VECTASHIELD® Antifade Mounting Medium with DAPI?
The signal word is no signal word.
What is the physical form of VECTASHIELD® Antifade Mounting Medium with DAPI?
VECTASHIELD® Antifade Mounting Medium with DAPI is a liquid with purple color. It has no data available odor.
What is the solubility of VECTASHIELD® Antifade Mounting Medium with DAPI?
No data available
What is VECTASHIELD® Antifade Mounting Medium with DAPI used for?
Laboratory chemicals
What is the melting point of VECTASHIELD® Antifade Mounting Medium with DAPI?
The melting point is Not applicable and the boiling point is No data available.