NextSDS Logo
Safety Data Sheet EN

MOBIL SHC GEAR 1500

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOBIL SHC GEAR 1500

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Gear oil

Uses advised against

This product is not recommended for any industrial, professional or consumer use other than the identified uses above.

Manufacturers & Suppliers

EXXON MOBIL CORPORATION logo

EXXON MOBIL CORPORATION

manufacturer

22777 Springwoods Village Parkway Spring, TX 77389 USA

800-662-4525

http://www.sds.exxonmobil.com

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

+1 703-741-5970

CHEMTREC

+1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
benzenamine, n-phenyl-, reaction products with 2,4,4-trimethylpentene 68411-46-1 3% No
kerosene 8008-20-6 0.3% No
amines, c12-14-tert-alkyl 68955-53-3 0.3% No

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

Symptoms: Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Get medical attention if symptoms occur. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. If product is injected into or under the skin, or into any part of the body, the individual should be evaluated immediately by a physician as a surgical emergency.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Use standard firefighting procedures and consider the hazards of other involved materials. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. Assure an extended cooling down period to prevent re-ignition. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Confine the spill immediately with booms. Remove from the surface by skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants. Warn other shipping.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant. Remove from the surface by skimming or with suitable absorbents.

Materials: water, inert dry material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). This material is a static accumulator.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Pale yellow
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
Not available.
Boiling Point
>315.56°C (>600°F)
Flash Point
Open cup: >210°C (>410°F) [ASTM D-92]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
<0.1 mm Hg [20 °C]
Vapor Density
---
Relative Density
0.9
Bulk Density
---
Density
---
Flammability
Ignitable
Upper Explosive Limit
7%
Lower Explosive Limit
0.9%
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
>3.5
Solubility In Water
Negligible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
1500 cSt [40 °C] [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

High energy sources of ignition. Excessive heat.

Incompatible

Strong oxidizers

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Conclusion/Summary Acute toxicity : Not expected to be harmful to aquatic organisms. Chronic toxicity : Not expected to demonstrate chronic toxicity to aquatic organisms.

Not expected to be harmful to aquatic organisms (acute) or demonstrate chronic toxicity (chronic).

Persistence and degradability

Not determined.

Not determined.

Bioaccumulative potential

Not determined.

Not determined.

Mobility in soil

Mobility : Base oil component -- Expected to partition to sediment and wastewater solids. Low solubility and floats and is expected to migrate from water to the land.

Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOBIL SHC GEAR 1500?

The signal word is no signal word.

What is the physical form of MOBIL SHC GEAR 1500?

MOBIL SHC GEAR 1500 is a liquid. with pale yellow color. It has characteristic odor.

What is MOBIL SHC GEAR 1500 used for?

Gear oil

What is the melting point of MOBIL SHC GEAR 1500?

The melting point is Not available. and the boiling point is >315.56°C (>600°F).