NextSDS Logo
Safety Data Sheet EN

Magnesium chloride solution

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Magnesium chloride solution
Product Code
M1028

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals, Synthesis of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Inc.

manufacturer

3050 SPRUCE ST ST. LOUIS MO 63103 UNITED STATES

+1 314 771-5765

Emergency Contacts

CHEMTREC

800-424-9300

24 Hours/day; 7 Days/week

CHEMTREC

+1-703-527-3887

24 Hours/day; 7 Days/week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Hydrogen chloride gas, Magnesium oxide. Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Not required; except in case of aerosol formation.

Skin/Body

not required

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
liquid
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
()Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.080 g/cm3
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Violent reactions possible with: The generally known reaction partners of water.

Avoid

no information available

Incompatible

Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Mixture No data available

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

12.6 Endocrine disrupting properties

No data available

12.7 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste material must be disposed of in accordance with the national and local regulations.

Disposal

Leave chemicals in original containers. No mixing with other waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Magnesium chloride solution?

The signal word is no signal word.

What is the physical form of Magnesium chloride solution?

Magnesium chloride solution is a liquid . It has no data available odor.

What is Magnesium chloride solution used for?

Laboratory chemicals, Synthesis of substances

What is the melting point of Magnesium chloride solution?

The melting point is No data available and the boiling point is No data available.