Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sodium L-lactate
- Product Code
- 71718
- Chemical Name
- Sodium L-lactate
Regulatory Identifiers
- CAS Number
- 867-56-1 Check regulations →
Identified Uses
Laboratory chemicals, Synthesis of substances
Uses advised against
The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipient's responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.
Manufacturers & Suppliers
Sigma-Aldrich Inc.
manufacturer
3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES
+1 314 771-5765
Emergency Contacts
CHEMTREC
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium L-(+)-lactate EC: 212-762-3 | 867-56-1 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
rinse out with plenty of water. Remove contact lenses.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Sodium oxides. Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.
Suppress (knock down) gases/vapors/mists with a water spray jet.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with impervious gloves. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L Splash contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.
Violent reactions possible with: Strong oxidizing agents
Exposure to moisture may affect product quality.
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the national and local regulations.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sodium L-lactate?
The signal word is no signal word.
What is the physical form of Sodium L-lactate?
Sodium L-lactate is a solid appearing as form: solid, color: colorless with colorless color. It has no data available odor.
What is Sodium L-lactate used for?
Laboratory chemicals, Synthesis of substances
What are the hazard statements for Sodium L-lactate?
This substance has 1 hazard statement:
- H401: Toxic to aquatic life.
What is the melting point of Sodium L-lactate?
The melting point is 163 - 165 °C (325 - 329 °F) and the boiling point is 115 °C 239 °F at ca.1,013.25 hPa - OECD Test Guideline 103.