Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ecgonine methyl ester-D3 solution
- Product Code
- E-002
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Synthesis of substances
Manufacturers & Suppliers
Sigma-Aldrich Inc.
manufacturer
3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES
+1 314 771-5765
Emergency Contacts
CHEMTREC
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetonitrile EC: 200-835-2 | 75-05-8 | 90 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air. If breathing stops: mouth-to-mouth breathing or artificial respiration. Oxygen if necessary. Immediately call in physician.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
immediately make victim drink water (two glasses at most). Consult a physician.
Immediate Medical Attention
Immediately call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Pay attention to flashback. Vapors are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Ecgonine methyl ester (1.0 mg/ml) in Acetonitrile
---
Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile
---
Benzoylecgonine-D3 0.1 mg/ml in Methanol
UFI: HPN6-F04N-E001-17MA
Diethylene glycol dimethyl ether
CAS: 111-96-6
(±)-Methamphetamine-D5 solution
---
Diethylbenzen Mix (3E) standard solution
---
Omega 3 fatty acid ethyl ester
---
Diethylene glycol monoethyl ether
CAS: 111-90-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when vapours/aerosols are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
required. Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapors may form explosive mixture with air.
No data available
Warming.
Acids, Bases, Oxidizing agents, Reducing agents, Alkali metals
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No data available
12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Other adverse effects
12.1 Toxicity
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
No mixing with other waste.
Waste material must be disposed of in accordance with the national and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1648
- Shipping Name
- AcetonitrileSOLUTION
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ecgonine methyl ester-D3 solution?
The signal word is danger.
What is the physical form of Ecgonine methyl ester-D3 solution?
Ecgonine methyl ester-D3 solution is a liquid .
What is Ecgonine methyl ester-D3 solution used for?
Laboratory chemicals, Synthesis of substances
What are the hazard statements for Ecgonine methyl ester-D3 solution?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapor.
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
- H319: Causes serious eye irritation.