Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile
- Product Code
- LGCAMP1345.07-11
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
This product is for research and development only
Uses advised against
Not to be used for human or animal consumption
Manufacturers & Suppliers
VHG LGC Standards
manufacturer
276 Abby Road, Manchester, NH 03103, UNITED STATES OF AMERICA
+1 (603) 622-7660
http://lgcstandards.com
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
+1 703-741-5970
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If symptoms persist, call a physician. If breathing has stopped, give artificial respiration. Get medical attention immediately.
Symptoms: Coughing and/ or wheezing. Difficulty in breathing.
Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If symptoms persist, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.
Symptoms: May cause redness and tearing of the eyes. Burning sensation.
Do NOT induce vomiting. Rinse mouth. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical. Carbon dioxide (CO2). Water spray. Alcohol resistant foam.
Do not scatter spilled material with high pressure water streams.
Risk of ignition. Keep product and empty container away from heat and sources of ignition.
In the event of fire, cool tanks with water spray.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas. Stop leak if you can do it without risk. Do not touch or walk through spilled material. Keep people away from and upwind of spill/leak.
Keep out of drains, sewers, ditches and waterways.
Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labeled containers.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Ecgonine methyl ester (1.0 mg/ml) in Acetonitrile
---
Ecgonine methyl ester-D3 solution
---
Nitrazepam (1.0 mg/ml) in Acetonitrile
---
Benzoylecgonine, 1mg/ml in Methanol
UFI: 8QAJ-30ND-F009-RKM3
Aripiprazole 1.0 mg/ml in Acetonitrile
---
Benzoylecgonine-D3 0.1 mg/ml in Methanol
UFI: HPN6-F04N-E001-17MA
Benzoylecgonine-D8 (1.0 mg/ml) in Methanol
---
Zopiclone 1.0 mg/ml in Acetonitrile
UFI: HHEP-P03Q-U007-RT9D
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use personal protection equipment. Avoid breathing vapors or mists. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use with local exhaust ventilation. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers. Use according to package label instructions. Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Remove contaminated clothing and shoes. In case of insufficient ventilation, wear suitable respiratory equipment.
Please refer to the manufacturer's certificate for specific storage and transport temperature conditions. Store only in the original receptacle unless other advice is given on the CoA. Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity). Keep in properly labeled containers. Do not store near combustible materials. Keep in an area equipped with sprinklers. Store in accordance with the particular national regulations. Store in accordance with local regulations. Keep out of the reach of children. Store locked up.
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Remove contaminated clothing and shoes.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Showers Eyewash stations Ventilation systems.
Wear protective butyl rubber gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. Wear suitable gloves. Impervious gloves.
Avoid contact with eyes. Wear safety glasses with side shields (or goggles). Tight sealing safety goggles.
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron. Antistatic boots.
Do not allow into any sewer, on the ground or into any body of water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
None under normal processing.
Heat, flames and sparks. Excessive heat.
None known based on information supplied.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
Persistence and degradability
Bioaccumulation
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Should not be released into the environment.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1648
- Shipping Name
- Acetonitrile mixture
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
LGC has not confirmed that the chemical substances in this product are on the TSCA Inventory, and LGC is distributing this product solely for use either in applications statutorily exempt from TSCA and regulated under other laws (e.g., FFDCA, FIFRA) or in research and development activities in accordance with the TSCA Inventory R&D exemption provided at 40 CFR 720.36.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile?
The signal word is danger.
What is the physical form of Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile?
Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile is a liquid appearing as liquid with colorless color. It has aromatic odor.
What is the solubility of Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile?
No data available
What is Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile used for?
This product is for research and development only
What are the hazard statements for Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile?
This substance has 6 hazard statements:
- H225: Highly flammable liquid and vapor
- H302: Harmful if swallowed
- H312: Harmful in contact with skin
- H319: Causes serious eye irritation
- H332: Harmful if inhaled
- H360: May damage fertility or the unborn child
What is the melting point of Ecgonine Methyl Ester 1.0 mg/ml in Acetonitrile?
The melting point is -45.7 °C / -50.3 °F and the boiling point is 81.6 °C / 178.9 °F.