Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SKC-S
Regulatory Identifiers
- CAS Number
- 64742-49-0 Check regulations →
Identified Uses
Non-destructive testing Restricted to professional users.
Uses advised against
None known.
Manufacturers & Suppliers
Magnaflux
manufacturer
155 Harlem Ave. 60025 Glenview, IL USA
847-657-5300
http://www.magnaflux.com/Magnaflux
Emergency Contacts
poison control
1-800-222-1222
24/7
CHEMTREC
800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Naphtha (petroleum), hydrotreated light | 64742-49-0 | 95 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Bring the person into fresh air and stay with him/her.
Remove contaminated clothing and shoes immediately. Ensure to wash exposed skin thoroughly with water and soap. Skin cleanser can be used. DO NOT use solvents or thinners. If skin irritation occurs: Get medical advice/attention.
Flush eyes with water or saline water (20-30 °C) for at least 5 minutes. Remove contact lenses. Seek medical assistance and continue flushing during transport.
Immediately call a POISON CENTER/doctor. Do not induce vomiting! If vomiting occurs, keep head facing down so that vomit does not get into the lungs. Call a doctor or ambulance.
Symptoms: Symptoms of chemical pneumonia can appear after several hours.
Immediate Medical Attention
Call 911 and give immediate treatment (first aid). Immediately call a POISON CENTER/doctor. Call a doctor or ambulance.
Medical Treatment
People who have swallowed the product should therefore be kept under medical attention for at least 48 hours.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol-resistant foam, carbon dioxide, powder, water mist.
Waterjets should not be used, since they can spread the fire.
Highly flammable liquid and vapour. In use may form flammable/explosive vapour-air mixture. Fire will result in dense smoke. Exposure to combustion products may harm your health.
Closed containers, which are exposed to fire, should be cooled with water.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing to prevent contact.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Storages not yet ignited must be cooled by water mist. Remove flammable materials if conditions allow it. Avoid direct contact with spilled substances. Contaminated areas may be slippery.
Avoid discharge to lakes, streams, sewers, etc.
cleaning should be performed with normal cleaning agents. Avoid use of solvents.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid direct contact with the product. Use non-sparking tools.
Must be stored in a cool and well-ventilated area, away from possible sources of ignition. No specific requirements.
Smoking, drinking and consumption of food is not allowed in the work area.
Take action to prevent static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The formation of vapours must be kept at a minimum and below current limit values (see above). Installation of a local exhaust system if normal air flow in the work room is not sufficient is recommended. Ensure eyewash and emergency showers are clearly marked.
Material: Nitrile, Glove thickness: 0,38 mm, Breakthrough time: > 480 min, Standards: EN374-2, EN374-3, EN388
Type: Safety glasses, Standards: EN166
In case of inadequate ventilation wear respiratory protection. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Dedicated work clothing should be worn.
Keep damming materials near the workplace. If possible, collect spillage during work.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under the conditions, noted in section 7 "Handling and storage".
No data available.
None known.
Avoid static electricity. Do not expose to any forms of heat (e.g. solar radiation). May lead to excess pressure.
Strong acids, strong bases, strong oxidizing agents, and strong reducing agents.
Under normal conditions of storage and use, hazardous decomposition products should not be produced
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
12.2. PERSISTENCE AND DEGRADABILITY
12.2. PERSISTENCE AND DEGRADABILITY
Based on available data, the classification criteria are not met.
12.3. BIOACCUMULATIVE POTENTIAL
12.3. BIOACCUMULATIVE POTENTIAL
Based on available data, the classification criteria are not met.
12.5. RESULTS OF PBT AND VPVB ASSESSMENT
The mixture does not contain any substances known to fulfil the criteria for PBT and vPvB classification.
12.6. OTHER ADVERSE EFFECTS
None known.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1268
- Shipping Name
- Petroleum Distillates, n.o.s. (Naphtha)
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SKC-S?
The signal word is danger.
What is the physical form of SKC-S?
SKC-S is a liquid with clear color. It has hydrocarbon odor.
What is SKC-S used for?
Non-destructive testing Restricted to professional users.
What are the hazard statements for SKC-S?
This substance has 4 hazard statements:
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of SKC-S?