NextSDS Logo
Safety Data Sheet EN

SKC-S

CAS 64742-49-0

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SKC-S

Regulatory Identifiers

CAS Number
64742-49-0 Check regulations →

Identified Uses

Non-destructive testing Restricted to professional users.

Uses advised against

None known.

Manufacturers & Suppliers

Magnaflux logo

Magnaflux

manufacturer

155 Harlem Ave. 60025 Glenview, IL USA

847-657-5300

http://www.magnaflux.com/Magnaflux

Emergency Contacts

poison control

1-800-222-1222

24/7

CHEMTREC

800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Asp. Tox. Cat. 1 H304
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapour.
H304 May be fatal if swallowed and enters airways.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P261 Avoid breathing mist/vapour.
P264 Wash hands and exposed skin thoroughly after handling.
P280 Wear eye protection/protective gloves/protective clothing.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P302 + P350 IF ON SKIN: Gently wash with plenty of soap and water.
P312 Call a POISON CENTER/doctor if you feel unwell.
P331 Do NOT induce vomiting.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P370 + P378 In case of fire: Use water mist/carbon dioxide/alcohol-resistant foam to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container in accordance with local regulation

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Naphtha (petroleum), hydrotreated light 64742-49-0 95 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bring the person into fresh air and stay with him/her.

Skin contact

Remove contaminated clothing and shoes immediately. Ensure to wash exposed skin thoroughly with water and soap. Skin cleanser can be used. DO NOT use solvents or thinners. If skin irritation occurs: Get medical advice/attention.

Eye contact

Flush eyes with water or saline water (20-30 °C) for at least 5 minutes. Remove contact lenses. Seek medical assistance and continue flushing during transport.

Ingestion

Immediately call a POISON CENTER/doctor. Do not induce vomiting! If vomiting occurs, keep head facing down so that vomit does not get into the lungs. Call a doctor or ambulance.

Symptoms: Symptoms of chemical pneumonia can appear after several hours.

Immediate Medical Attention

Call 911 and give immediate treatment (first aid). Immediately call a POISON CENTER/doctor. Call a doctor or ambulance.

Medical Treatment

People who have swallowed the product should therefore be kept under medical attention for at least 48 hours.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam, carbon dioxide, powder, water mist.

Unsuitable media

Waterjets should not be used, since they can spread the fire.

Specific hazards

Highly flammable liquid and vapour. In use may form flammable/explosive vapour-air mixture. Fire will result in dense smoke. Exposure to combustion products may harm your health.

Instructions

Closed containers, which are exposed to fire, should be cooled with water.

Firefighter Protection

Wear self-contained breathing apparatus and protective clothing to prevent contact.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Storages not yet ignited must be cooled by water mist. Remove flammable materials if conditions allow it. Avoid direct contact with spilled substances. Contaminated areas may be slippery.

Environmental

Avoid discharge to lakes, streams, sewers, etc.

Cleanup methods

cleaning should be performed with normal cleaning agents. Avoid use of solvents.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid direct contact with the product. Use non-sparking tools.

Storage

Must be stored in a cool and well-ventilated area, away from possible sources of ignition. No specific requirements.

Hygiene

Smoking, drinking and consumption of food is not allowed in the work area.

Fire prevention

Take action to prevent static discharges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The formation of vapours must be kept at a minimum and below current limit values (see above). Installation of a local exhaust system if normal air flow in the work room is not sufficient is recommended. Ensure eyewash and emergency showers are clearly marked.

Hands

Material: Nitrile, Glove thickness: 0,38 mm, Breakthrough time: > 480 min, Standards: EN374-2, EN374-3, EN388

Eyes

Type: Safety glasses, Standards: EN166

Respiratory

In case of inadequate ventilation wear respiratory protection. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Dedicated work clothing should be worn.

Environmental

Keep damming materials near the workplace. If possible, collect spillage during work.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear
Colour Intensity
---
Form
---
Odor
Hydrocarbon
Odor Threshold
No data available
Ph
Neutral
Melting Point
No data available
Boiling Point
~245 °F / ~118 °C
Flash Point
59 °F / 15 °C
Freezing Point
---
Softening Point
Does not apply to liquids.
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
~1
Vapor Pressure
---
Vapor Density
---
Relative Density
0.76 (68 °F)
Bulk Density
---
Density
No relevant or available data due to the nature of the product.
Flammability
The material is ignitable.
Upper Explosive Limit
No relevant or available data due to the nature of the product.
Lower Explosive Limit
No relevant or available data due to the nature of the product.
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
---
Solubility
---
Partition Coefficient
No data available
Solubility In Water
No data available
Solubility In Fat
No data available
Molecular Weight
---
Voc Content
750 g/L
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
0.786 centistokes (104 °F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under the conditions, noted in section 7 "Handling and storage".

Reactivity

No data available.

Hazardous reactions

None known.

Avoid

Avoid static electricity. Do not expose to any forms of heat (e.g. solar radiation). May lead to excess pressure.

Incompatible

Strong acids, strong bases, strong oxidizing agents, and strong reducing agents.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. TOXICITY

No data available.

12.2. PERSISTENCE AND DEGRADABILITY

12.2. PERSISTENCE AND DEGRADABILITY

Based on available data, the classification criteria are not met.

Based on available data, the classification criteria are not met.

12.3. BIOACCUMULATIVE POTENTIAL

12.3. BIOACCUMULATIVE POTENTIAL

12.3. BIOACCUMULATIVE POTENTIAL

Based on available data, the classification criteria are not met.

Based on available data, the classification criteria are not met.

12.5. RESULTS OF PBT AND VPVB ASSESSMENT

This mixture/product does not contain any substances known to fulfil the criteria for PBT and vPvB classification.

The mixture does not contain any substances known to fulfil the criteria for PBT and vPvB classification.

12.6. OTHER ADVERSE EFFECTS

None known.

None known.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1268
Shipping Name
Petroleum Distillates, n.o.s. (Naphtha)
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SKC-S?

The signal word is danger.

What is the physical form of SKC-S?

SKC-S is a liquid with clear color. It has hydrocarbon odor.

What is SKC-S used for?

Non-destructive testing Restricted to professional users.

What are the hazard statements for SKC-S?

This substance has 4 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.

What is the melting point of SKC-S?

The melting point is No data available and the boiling point is ~245 °F / ~118 °C.