Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- THERMAL HL90
- Product Code
- 8940143, 8940142
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
temperature control liquid working temperature range: -90°C - +200°C
Manufacturers & Suppliers
Julabo GmbH
manufacturer
Gerhard-Juchheim-Str. 1, D-77960 Seelbach/Deutschland
+49(0)782351-180
Emergency Contacts
Emergency Contact
+49(0)89-19240
24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Void
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
Do not induce vomiting; call for medical help immediately. If symptoms persist consult doctor.
Immediate Medical Attention
Do not induce vomiting; call for medical help immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, sand, extinguishing powder.
Water with full jet, Water spray
No further relevant information available.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Particular danger of slipping on leaked/spilled product.
Do not allow product to reach sewage system or any water course.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep receptacles tightly sealed.
Store in cool, dry place in tightly closed receptacles.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Fluorocarbon rubber (Viton), Butyl rubber, BR. Recommended material thickness: Butylkautschuk: 0,50 mm +/- 0,10 mm, Fluorkautschuk: 0,75 mm +/- 0,10 mm. Penetration time: Basis: DGUV 212-007. Permeation (Fluorkautschuk): + Level 6 (> 240 min). Permeation (Butykautschuk): + Level 6 (> 480 min). The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Goggles recommended during refilling. Tightly sealed goggles.
Suitable respiratory protective device recommended. Filter type A2. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
Please refer 10.2
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
No further relevant information available.
12.3 Bioaccumulative potential
No further relevant information available.
12.4 Mobility in soil
No further relevant information available.
12.5 Results of PBT and vPvB assessment
The substance is not considered to be PBT or vPvB.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
Smaller quantities can be disposed of with household waste.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for THERMAL HL90?
The signal word is no signal word.
What is the physical form of THERMAL HL90?
THERMAL HL90 is a fluid with colourless color. It has odourless odor.
What is THERMAL HL90 used for?
temperature control liquid working temperature range: -90°C - +200°C
What is the melting point of THERMAL HL90?
The melting point is Undetermined. and the boiling point is >220 °C.