Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOBILCUT 140
- Product Code
- 2015703010J0, 662114-60
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Water-miscible cutting fluid
Uses advised against
This product is not recommended for any industrial, professional or consumer use other than the Identified Uses above.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BVBA
national supplier
POLDERDIJKWEG, B-2030 Antwerpen, Belgium
+32 3 790 3111
http://www.msds.exxonmobil.com
Emergency Contacts
Emergency Contact
(+44) 870 8200418
24 Hour
Emergency Contact
(+353) 19014670
24 Hour
National Poison Control Centre
111
National Poison Control Centre
(+353)1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 3-iodo-2-propynyl butylcarbamate EC: 259-627-5 | 55406-53-6 | 0.2% | Yes |
| OLIGOMERISATION PRODUCTS OF ETHYLENE OXIDE WITH REACTION PRODUCTS OF RAPE OIL AND ETHANOLAMINE EC: 932-164-2 | 85536-23-8 | 1 - 5% | Yes |
| boric acid EC: 233-139-2 | 10043-35-3 | 5.5% | Yes |
| ETHANOL, 2-(2 BUTOXYETHOXY)- EC: 203-961-6 | 112-34-5 | 1 - 5% | Yes |
| ETHOXYLATED C16-C18 FATTY ALCOHOLS EC: 500-236-9 | 68920-66-1 | 2.5 - 5% | Yes |
| FATTY ACIDS, TALL-OIL, COMPDS. WITH ETHANOLAMINE EC: 268-640-5 | 68132-47-8 | 1 - 5% | Yes |
| REACTION PRODUCTS OF PARAFORMALDEHYDE AND 2-HYDROXYPROPYLAMINE (RATIO 3:2) | --- | 1 - 2.5% | Yes |
Notes
All concentrations are percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume.
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately remove from further exposure. Get immediate medical assistance. Give supplemental oxygen, if available. If breathing has stopped, assist ventilation with a mechanical device.
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Symptoms: Itching, pain, redness, swelling of skin. Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection. Itching and rash from allergic skin reaction.
Flush thoroughly with water for at least 15 minutes. Get medical assistance.
Symptoms: Eye pain, redness, tearing, swelling of eyelids, itching.
First aid is normally not required. Seek medical attention if discomfort occurs.
Immediate Medical Attention
Get immediate medical assistance. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Medical Treatment
Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Pressurised mists may form a flammable mixture. Hazardous material.
Evacuate area. Prevent run-off from fire control or dilution from entering streams, sewers or drinking water supply. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Firefighters should consider protective equipment indicated in Section 8.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Notify relevant authorities in accordance with all applicable regulations. Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind areas if required.
Normal antistatic work clothes are usually adequate.
Full body suit of chemical resistant, antistatic material is recommended.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid all personal contact. Prevent small spills and leakage to avoid slip hazard. Small metal particles from machining may cause abrasion of the skin and may predispose to dermatitis. Consult local applicable standards for guidance. Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity).
Storage Temperature: 5°C (41°F) - 40°C (104°F)
Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or earthing procedures. However, bonding and earthing may not eliminate the hazard from static accumulation. Static Accumulator: This material is a static accumulator.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation should be provided so that exposure limits are not exceeded.
Chemical resistant gloves are recommended. Nitrile, minimum 0.38 mm thickness or comparable protective barrier material with a high performance level for continuous contact use conditions, permeation breakthrough minimum 480 minutes in accordance with CEN standards EN 420 and EN 374.
Chemical goggles are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: Particulate air-purifying respirator approved for dust or oil mist is recommended. European Committee for Standardization (CEN) standards EN 136, 140 and 405 provide respirator masks and EN 149 and 143 provide filter recommendations. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
Chemical/oil resistant clothing is recommended.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Heat/ Freezing temperatures., High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
Expected to be harmful to aquatic organisms. May cause long-term adverse effects in the aquatic environment.
12.2. PERSISTENCE AND DEGRADABILITY
12.3. BIOACCUMULATIVE POTENTIAL
12.3. BIOACCUMULATIVE POTENTIAL
The components have the potential to bioaccumulate.
12.4. MOBILITY IN SOIL
12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)
The material does not meet the criteria for PBT or vPvB as defined in REACH Annex XIII.
12.6. OTHER ADVERSE EFFECTS
No adverse effects are expected.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOBILCUT 140?
The signal word is danger.
What is the physical form of MOBILCUT 140?
MOBILCUT 140 is a liquid with yellow color. It has characteristic odor.
What is MOBILCUT 140 used for?
Water-miscible cutting fluid
What are the hazard statements for MOBILCUT 140?
This substance has 6 hazard statements:
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H341: Suspected of causing genetic defects.
- H350: May cause cancer.
- H412: Harmful to aquatic life with long lasting effects.