Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 2-Propanol
- Product Code
- A464-1, A464-4, A464-4LC, A464RS-200, A464SK-4, A464SS50, A464RS50
- Synonyms
- 2-Propanol; IPA; Isopropyl alcohol; Propan-2-ol; Isopropanol
Regulatory Identifiers
- CAS Number
- 67-63-0 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
Food, drug, pesticide or biocidal product use.
Manufacturers & Suppliers
Fisher Scientific Company
importer
One Reagent Lane, Fair Lawn, NJ 07410
(201) 796-7100
Fisher Scientific
distributor
112 Colonnade Road, Ottawa, ON K2E 7L6, Canada
1-800-234-7437
Emergency Contacts
CHEMTREC®
800-424-9300
CHEMTREC®
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isopropyl alcohol | 67-63-0 | 95% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention. If not breathing, give artificial respiration.
Symptoms: Difficulty in breathing. May cause central nervous system depression: Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention if symptoms occur.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do NOT induce vomiting. Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO₂, dry chemical, dry sand, alcohol-resistant foam. Water mist may be used to cool closed containers.
Water may be ineffective
Flammable. Risk of ignition. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Containers may explode when heated.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. Thermal decomposition can lead to release of irritating gases and vapors.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Remove all sources of ignition. Take precautionary measures against static discharges. Avoid contact with skin, eyes or clothing.
Should not be released into the environment. See Section 12 for additional Ecological Information.
Soak up with inert absorbent material. Use spark-proof tools and explosion-proof equipment.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Keep away from open flames, hot surfaces and sources of ignition. Use spark-proof tools and explosion-proof equipment. Use only non-sparking tools. Take precautionary measures against static discharges. Do not get in eyes, on skin, or on clothing. Do not breathe mist/vapors/spray. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded.
Keep away from heat, sparks and flame. Flammables area. Keep container tightly closed in a dry and well-ventilated place.
Keep away from open flames, hot surfaces and sources of ignition. Use spark-proof tools and explosion-proof equipment. Use only non-sparking tools. Take precautionary measures against static discharges. All metal parts of the equipment must be grounded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure that eyewash stations and safety showers are close to the workstation location. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Wear appropriate protective gloves and clothing to prevent skin exposure. Glove material | Breakthrough time | Glove thickness | Glove comments: Butyl rubber | > 480 minutes | 0.5 mm | Permeation rate < 0.9; Nitrile rubber | > 360 - 480 minutes | 0.35 - 0.55 mm | µg/cm2/min. As tested under EN374-3. Determination of Resistance to Permeation by Chemicals. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.
Goggles
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly Recommended Filter type: Organic gases and vapours filter Type A Brown conforming to EN14387. When RPE is used a face piece Fit Test should be conducted
Wear appropriate protective gloves and clothing to prevent skin exposure.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous polymerization does not occur.
Heat, flames and sparks. Keep away from open flames, hot surfaces and sources of ignition.
Strong oxidizing agents, Acids, Halogens, Acid anhydrides
Carbon monoxide (CO), Carbon dioxide (CO₂), peroxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
Persistence and Degradability
Bioaccumulation/ Accumulation
Mobility
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste.
Chemical waste generators must also consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1219
- Shipping Name
- Isopropanol
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is 2-Propanol known by?
2-Propanol is also known as: 2-Propanol; IPA; Isopropyl alcohol; Propan-2-ol; Isopropanol
What is the hazard signal word for 2-Propanol?
The signal word is danger.
What is the physical form of 2-Propanol?
2-Propanol is a liquid with colorless color. It has alcohol-like odor.
What is 2-Propanol used for?
Laboratory chemicals.
What are the hazard statements for 2-Propanol?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapor
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation
- H336: May cause drowsiness and dizziness
- H372: May cause damage to organs through prolonged or repeated exposure
What is the melting point of 2-Propanol?
The melting point is -89.5 °C / -129.1 °F and the boiling point is 81 - 83 °C / 177.8 - 181.4 °F.