Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 3-Indolybutyric acid
- Product Code
- I108273
- Chemical Name
- 3-Indolybutyric acid
Regulatory Identifiers
- CAS Number
- 133-32-4 Check regulations →
Identified Uses
Laboratory chemicals, Manufacture of substances.
Manufacturers & Suppliers
ALADDIN SCIENTIFIC CORPORATION
manufacturer
14078 Meridian Parkway, Riverside, CA. 92518
+1 (833) 552-7181
Emergency Contacts
CHEMTREC®
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS06
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 3-Indolybutyric acid | 133-32-4 | 98% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Immediate Medical Attention
Take victim immediately to hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
no data available
Hazardous decomposition products formed under fire conditions.
Firefighter Protection
Wear self contained breathing apparatus for fire fighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas.
Prevent further leakage or spillage if safe to do so. Discharge into the environment must be avoided.
Pick up and arrange disposal without creating dust. Sweep up and shovel.
Materials: suitable, closed containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Keep container tightly closed in a dry and well-ventilated place. Light sensitive. Store under inert gas. Air sensitive. Keep in a dry place.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Where risk assessment shows air-purifying respirators are appropriate use a full-face particle respirator type N99 (US) or type P2 (EN 143) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Complete suit protecting against chemicals. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
no data available
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
no data available
no data available
no data available
Strong oxidizing agents, Strong bases
Hazardous decomposition products formed under fire conditions.- Carbon oxides, nitrogen oxides (NOx)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Harmful to aquatic life.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.
Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2811
- Transport Class
- 6.1
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 3-Indolybutyric acid?
The signal word is danger.
What is the physical form of 3-Indolybutyric acid?
3-Indolybutyric acid is a solid appearing as form: powder color: beige with beige color.
What is 3-Indolybutyric acid used for?
Laboratory chemicals, Manufacture of substances.
What are the hazard statements for 3-Indolybutyric acid?
This substance has 4 hazard statements:
- H301: Toxic if swallowed
- H315: Causes skin irritation
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation
What is the melting point of 3-Indolybutyric acid?
The melting point is 122 - 125 °C (252 - 257 °F) .