NextSDS Logo
Safety Data Sheet EN

Colortone #5040 Black

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Colortone #5040 Black

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Surface Decoration and Colorant

Uses advised against

No information available

Manufacturers & Suppliers

S

Stewart McDonald Guitar Shop Supply

manufacturer

21 N Shafer St., Suite A, Athens, OH 45701

(216) 631-5309

Emergency Contacts

Emergency Contact

(216) 631-5309

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 5
STOT SE Cat. 3
Flam. Liq. Cat. 4

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H227 Combustible liquid
H336 May cause drowsiness or dizziness

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking
P233 Keep container tightly closed when product is not in use.
P240 Ground/bond container and receiving equipment
P241 Use explosion-proof electrical/ventilating/lighting/equipment
P242 Use only non-sparking tools
P243 Take precautionary measures against static discharge
P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P271 Use only outdoors or in a well-ventilated area
P280 Wear protective gloves/protective clothing/eye protection/face protection
P304 + P341 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing
P312 Call a POISON CENTER or doctor/physician if you feel unwell
P403 + P235 Store in a well-ventilated place. Keep cool
P405 Store locked up
P501 Dispose of contents/container to an approved waste disposal plant

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2-Propoxyethanol 2907-30-9 30 - 40% No
Chromium (Cr+3) compound dye --- 20 - 30% No
Diethylene Glycol monobutyl ether 112-34-5 10 - 20% No
2-Propanol, 1-methoxy 107-98-2 5 - 15% No
1,2-Propanediol 57-55-6 1 - 5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Immediate medical attention is not required. If symptoms persist, call a physician. Move to fresh air in case of accidental inhalation of vapors or decomposition products.

Skin contact

Wash off immediately with plenty of water. Immediate medical attention is not required. Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If skin irritation persists, call a physician.

Eye contact

Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Keep eye wide open while rinsing. If symptoms persist, call a physician.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Call a physician. Do NOT induce vomiting.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Dry chemical. Carbon dioxide (CO₂). Water spray (fog). Alcohol resistant foam.

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Specific hazards

Keep product and empty container away from heat and sources of ignition. Risk of ignition. Flammable.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Remove all sources of ignition. Evacuate personnel to safe areas. Ensure adequate ventilation, especially in confined areas. Keep people away from and upwind of spill/leak. Pay attention to flashback. Take precautionary measures against static discharges.

Environmental

Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. Do not flush into surface water or sanitary sewer system.

Cleanup methods

Soak up with inert absorbent material. Pick up the absorbed material and transfer to properly labeled containers for disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapors). Do not use mobile phones during handling. Never pierce, drill, grind, cut, saw or weld any empty container.

Storage

Keep away from heat, sparks, flame and other sources of ignition. Keep containers tightly closed in a cool, dry, well-ventilated place.

Fire prevention

Keep away from heat, sparks, flame and other sources of ignition. Take necessary action to avoid static electricity discharge.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Showers, Eyewash stations, Ventilation systems. A safety shower and eye wash station should be within walking distance of the work area. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment. Local exhaust should be used to maintain levels below the TLV and PEL.

Hands

Wear protective gloves and protective clothing that is resistant to chemical penetration. Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

Eyes

Tight sealing safety goggles. Wear full face shield if splashing of liquid is possible.

Respiratory

If exposure limits are exceeded or irritation is experienced, a NIOSH/MSHA approved respiratory protection should be worn.

Skin/Body

Wear protective gloves and protective clothing that is resistant to chemical penetration. Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Black liquid
Colour
No information available
Colour Intensity
---
Form
---
Odor
Ether-like
Odor Threshold
No information available
Ph
6 - 10
Melting Point
No information available
Boiling Point
< 110 °C / 230 °F
Flash Point
71 °C / 160 °F
Freezing Point
---
Softening Point
No information available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No information available
Vapor Pressure
---
Vapor Density
---
Relative Density
1.03
Bulk Density
No information available
Density
No information available
Flammability
---
Upper Explosive Limit
No information available
Lower Explosive Limit
No information available
Explosive Limits
---
Auto Ignition Temperature
No information available
Decomposition Temperature
No information available
Solubility
---
Partition Coefficient
No information available
Solubility In Water
No information available
Solubility In Fat
---
Molecular Weight
No information available
Voc Content
No information available
Metal Corrosion
---
Dynamic Viscosity
No information available
Kinematic Viscosity
No information available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of handling, use and transportation.

Reactivity

No data available.

Hazardous reactions

None under normal processing. Hazardous polymerization does not occur.

Avoid

Heat, flames and sparks. Take precautionary measures against static discharges. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Incompatible

None known based on information supplied.

Decomposition

Hazardous decomposition products may be released during prolonged heating like smokes, carbon monoxide and dioxide, nitrogen oxides (NOx), other toxic vapors.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Ecotoxicity

Ecotoxicity | Chemical Name | Algae/aquatic plants | Fish | Crustacea | | --- | --- | --- | --- | | Glycol ether PM alcohol 107-98-2 | - | 4600-10000 96 HOUR Leuciscus idus | - |

Persistence and degradability

No information available.

Bioaccumulation

No information available.

Other adverse effects

No information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal should be in accordance with applicable local, regional, national and international laws and regulations.

Disposal

Should not be released into the environment. This material, as supplied, is a hazardous waste according to federal regulations (40 CFR 261).

Waste Codes

D007 RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1263
Shipping Name
Paint
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Colortone #5040 Black?

The signal word is warning.

What is the physical form of Colortone #5040 Black?

Colortone #5040 Black is a liquid appearing as black liquid with no information available color. It has ether-like odor.

What is Colortone #5040 Black used for?

Surface Decoration and Colorant

What are the hazard statements for Colortone #5040 Black?

This substance has 2 hazard statements:

  • H227: Combustible liquid
  • H336: May cause drowsiness or dizziness

What is the melting point of Colortone #5040 Black?

The melting point is No information available and the boiling point is < 110 °C / 230 °F.