Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MAPP GAS
- Synonyms
- Petroleum Gas, MAPD, MAP,MAPP,Methyacetylene-Propadiene, Mixture of Methylacetylene and Propadiene
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Synthetic/Analytical chemistry.
Manufacturers & Suppliers
AIRGAS INC., on behalf of its subsidiaries
manufacturer
259 North Radnor-Chester Road Suite 100 Radnor, PA 19087-5283
1-610-687-5253
Emergency Contacts
Emergency Contact
1-866-734-3438
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS02
GHS04
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.
Immediately warm frostbite area with warm water (not to exceed 40.5 C, 105F). Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention. Try to warm up the frozen tissues and seek medical attention.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. DO NOT remove contact lenses, if worn. Obtain medical attention without delay, preferably from an ophthalmologist.
Immediate Medical Attention
Obtain medical attention without delay, preferably from an ophthalmologist. Get medical attention immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam or dry chemical.
Contains gas under pressure. Extremely flammable. In a fire or if heated, a pressure increase will occur and the container may burst or explode. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion.
In case of fire, allow gas to burn if flow cannot be shut off immediately. Apply water from a safe distance to cool container and protect surrounding area. If involved in fire, shut off flow immediately if it can be done without risk.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Immediately contact emergency personnel. Keep unnecessary personnel away. Use suitable protective equipment (section 8). Shut off gas supply if this can be done safely. Isolate area until gas has dispersed.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Immediately contact emergency personnel. Stop leak if without risk.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. High pressure gas. Do not puncture or incinerate container. Use equipment rated for cylinder pressure. Close valve after each use and when empty. Keep container closed. Keep away from heat, sparks and flame. To avoid fire, eliminate ignition sources. Protect cylinders from physical damage; do not drag, roll, slide, or drop. Use a suitable hand truck for cylinder movement.
Keep container in a cool, well-ventilated area. Keep container tightly closed and sealed until ready for use. Avoid all possible sources of ignition (spark or flame). Segregate from oxidizing materials. Cylinders should be stored upright, with valve protection cap in place, and firmly secured to prevent falling or being knocked over.
Keep away from heat, sparks and flame. To avoid fire, eliminate ignition sources.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists or dusts. Monogoggles.
Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. The applicable standards are (US) 29 CFR 1910.134 and (Canada) Z94.4-93. Self-contained breathing apparatus (SCBA) should be used to avoid inhalation of the product (in case of a large spill).
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Neoprene and Nitrile (NBR).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable. Stable as mixed; however, contains unstable materials (methylacetylene and propadiene).
Extremely reactive or incompatible with oxidizing agents. Reactive with metals.
May Occur. (Hazardous polymerization)
Avoid heating of mixture or venting of lights that could cause lighter materials to weather off(evaporate). Elevated tempertures and pressures. Polymerization catalysts, such as metal alkyls, can cause uncontrolled polymerization. Contamination with oxygen can cause propadiene to form hazardous peroxides.
oxidizing agents, metals, acetylide-forming metals (copper, silver and mercury). Copper alloys (such as brass) containing sixty six percent (66%) or more of copper.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No aquatic toxicity data available.
12.2 Persistence and degradability
Products of degradation are carbon oxides and water.
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
No known significant effects or critical hazards.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product removed from the cylinder must be disposed of in accordance with appropriate Federal, State, local regulation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1060
- Shipping Name
- Methyl Acetylene and Propadiene mixtures, stabilized
- Transport Class
- 2.1
- Packing Group
- Not applicable (gas)
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is MAPP GAS known by?
MAPP GAS is also known as: Petroleum Gas, MAPD, MAP,MAPP,Methyacetylene-Propadiene, Mixture of Methylacetylene and Propadiene
What is the hazard signal word for MAPP GAS?
The signal word is danger.
What is MAPP GAS used for?
Synthetic/Analytical chemistry.
What are the hazard statements for MAPP GAS?
This substance has 7 hazard statements:
- EUH029: Acts as a simple asphyxiant.
- H221: FLAMMABLE GAS.
- H260: Liquid or cold gas may cause frostbites.
- H280: CONTENTS UNDER PRESSURE.
- H281: Contact with rapidly expanding gases can cause frostbite.
- MAY CAUSE FLASH FIRE.
- CONTAINS MATERIAL THAT CAN CAUSE TARGET ORGAN DAMAGE.
What is the melting point of MAPP GAS?
The melting point is -102.8°C (-153°F) This is based on data for the following ingredient: propyne. Weighted average: -152.56°C (-242.6°F) .