NextSDS Logo
BI

BIS SIL SANITARY BK CQ 300ML*12 NLFR

NO SIGNAL WORD Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BIS SIL SANITARY BK CQ 300ML*12 NLFR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Agent d'étanchéité

Overview

BIS SIL SANITARY BK CQ 300ML*12 NLFR commonly used agent d'étanchéité.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

Precautionary Statements

  • P273: Éviter le rejet dans l'environnement.
  • P501: Éliminer le contenu/récipient conformément à la réglementation nationale.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

📍

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

🌍

NL

📞

+31 88 3235700

📠

+31 88 3235800

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA (INRS)

📞

+ 33 (0)1 45 42 59 59

🌍

FR

Centres Antipoison et de Toxicovigilance ANGERS

📞

02 41 48 21 21

🌍

FR

Centres Antipoison et de Toxicovigilance BORDEAUX

📞

05 56 96 40 80

🌍

FR

Centres Antipoison et de Toxicovigilance LILLE

📞

0800 59 59 59

🌍

FR

Centres Antipoison et de Toxicovigilance LYON

📞

04 72 11 69 11

🌍

FR

Centres Antipoison et de Toxicovigilance MARSEILLE

📞

04 91 75 25 25

🌍

FR

Centres Antipoison et de Toxicovigilance NANCY

📞

03 83 22 50 50

🌍

FR

Centres Antipoison et de Toxicovigilance PARIS

📞

01 40 05 48 48

🌍

FR

Centres Antipoison et de Toxicovigilance STRASBOURG

📞

03 88 37 37 37

🌍

FR

Centres Antipoison et de Toxicovigilance TOULOUSE

📞

05 61 77 74 47

🌍

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Agent d'étanchéité

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
distillats moyens (pétrole), hydrotraités
EC: 934-956-3
N/A 25-50% ⚠️ Hazardous
titaniumdioxide
EC: 236-675-5
13463-67-7 0.1-1% ⚠️ Hazardous
octamethylcyclotetrasiloxaan
EC: 209-136-7
556-67-2 0.025-0.25% ⚠️ Hazardous
4,5-dichloro-2-octyl-2H-isothiazole-3-one
EC: 264-843-8
64359-81-5 Not specified ⚠️ Hazardous
Dimethylbis[(1-oxoneodecyl)oxy]stannaan
EC: 273-028-6
68928-76-7 Not specified ⚠️ Hazardous

Additional Information

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Donner de l'air frais, consulter un médecin en cas de troubles. Aucune mesure particulière n'est requise.

👁️ Eye Contact

Rincer les yeux, sous l'eau courante, pendant plusieurs minutes, en écartant bien les paupières.

🍽️ Ingestion/Swallowing

Si les troubles persistent, consulter un médecin.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Dynamic Viscosity
Non déterminé.
📊 Cloud Point
Not available
📊 Solubility In Water
Pas ou peu miscible
📊 Relative Evaporation Rate
Not available
🧊 Melting Point
Non déterminé.
Critical Property
📊 Molecular Weight
Not available
🔥 Flammability
Non applicable.
📊 Decomposition Temperature
Non déterminé.
📊 Lower Explosive Limit
Non déterminé.
📊 State Under Standard Conditions
Not available
🧪 Physical State
Liquide
Critical Property
📊 Physical State Data
liquid
🔥 Flash Point
Non applicable.
Critical Property
📊 Solubility In Fat
Not available
💨 Vapor Pressure
Non déterminé.
📊 Crystallisation Point
Not available
📊 Voc Content
Not available
💨 Boiling Point
2230 °℃
Critical Property
🎨 Colour
Selon désignation produit
📊 Colour Intensity
Not available
📊 Upper Explosive Limit
Non déterminé.
🧪 Ph
Non déterminé.
💨 Evaporation Rate
Not available
👁️ Appearance
Not available
📊 Auto Ignition Temperature
>370 ℃
📊 Partition Coefficient
Non déterminé.
⚖️ Density
0,97 g/cm3
Critical Property
📊 Freezing Point
Non déterminé.
📊 Bulk Density
Not available
📊 Properties Status
Not available
📊 Softening Point
Not available
📊 Relative Density
Non déterminé.
👃 Odor
Caractéristique
📊 Solidification Point
Not available
📊 Kinematic Viscosity
Non déterminé.
💧 Solubility
Pas ou peu miscible
📊 Explosive Limits
Not available
📊 Odor Threshold
Non déterminé.
📊 Form
Not available
📊 Metal Corrosion
Not available
📊 Vapor Density
Non déterminé.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Le matériau des gants doit être imperméable et résistant au produit / à la substance / à la préparation. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Épaisseur du matériau recommandée: > 0,12 mm. Caoutchouc nitrile. Pour le mélange des produits chimiques mentionnés ci-dessous, le temps de pénétration doit être d'au moins 10 minutes (perméabilité selon la norme EN 374 section 3: taux 1).

👁️ Eye Protection

Lunettes de protection recommandées pour le transvasement.

😷 Respiratory Protection

N'est pas nécessaire.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

l'ONU

⚠️ Transport Hazard Class

néant

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BIS SIL SANITARY BK CQ 300ML*12 NLFR?

The signal word for this substance is "no signal word".

What is the physical form of BIS SIL SANITARY BK CQ 300ML*12 NLFR?

BIS SIL SANITARY BK CQ 300ML*12 NLFR is a liquide with selon désignation produit color. It has caractéristique odor.

What is the solubility of BIS SIL SANITARY BK CQ 300ML*12 NLFR?

Pas ou peu miscible

What is BIS SIL SANITARY BK CQ 300ML*12 NLFR used for?

Agent d'étanchéité

What are the hazard statements for BIS SIL SANITARY BK CQ 300ML*12 NLFR?

This substance has 1 hazard statements: H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

What is the melting point of BIS SIL SANITARY BK CQ 300ML*12 NLFR?

The melting point is Non déterminé. and the boiling point is 2230 °℃.