NextSDS Logo
DY

DYK CLEANER TI 1L*12 NLFR

DANGER Liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DYK CLEANER TI 1L*12 NLFR
Chemical Name
Methylethyl ketone
Synonyms
Methyl ethyl ketone

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119457290-43

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
Nettoyant
Uses Advised Against
Pas d'autres informations importantes disponibles.

Overview

DYK CLEANER TI 1L*12 NLFR (CAS: 78-93-3 ) is a incolore substance commonly used nettoyant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Liquide et vapeurs très inflammables.
  • H319: Provoque une sévère irritation des yeux.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P261: Éviter de respirer les vapeurs.
  • P370 + P378: En cas d'incendie: utiliser pour l'extinction: Brouillard d'eau, Mousse résistant à l'alcool, Poudre d'extinction, Dioxyde de carbone.
  • P403 + P233: Stocker dans un endroit bien ventilé. Maintenir le récipient fermé de manière étanche.
  • P501: Éliminer le contenu/récipient conformément à la réglementation locale/régionale/nationale/internationale.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

📍

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

🌍

NL

📞

+31 88 3235700

📠

+31 88 3235800

Bison International

national supplier

📍

Excelsiorlaan 27, B 3 B-1930 Zaventem

🌍

BE

📞

+32 3 710 92 92

📠

+32 3 710 92 90

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Antipoisons

📞

070 245245

🌍

BE

Emergency Contact

📞

8002 - 5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butanone
EC: 201-159-0
78-93-3 Not specified ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Donner de l'air frais, consulter un médecin en cas de troubles.

👁️ Eye Contact

Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en écartant bien les paupières. Si les troubles persistent, consulter un médecin.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Brouillard d'eau, Mousse résistant à l'alcool, Poudre d'extinction, Dioxyde de carbone

Unsuitable Extinguishing Media

Jet d'eau à grand débit

⚠️ Specific Fire Hazards

Pas d'autres informations importantes disponibles.

🛡️ Firefighter Protection Equipment

Aucune mesure particulière n'est requise.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🚨 Emergency Procedures

Porter un équipement de sécurité. Eloigner les personnes non protégées. Assurer une aération suffisante.

🌍 Environmental Precautions

Ne pas rejeter dans les canalisations, dans les eaux de surface et dans les nappes d'eau souterraines.

🧹 Cleanup Methods

Mettre dans des conteneurs spéciaux de récupération ou d'élimination. Recueillir les liquides à l'aide d'un produit absorbant.

Cleanup Materials:

produit absorbant (sable, kieselguhr, neutralisant d'acide, liant universel, sciure)

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Incolore
🎨 Colour
Incolore
📊 Colour Intensity
Not available
📊 Form
Liquide
👃 Odor
Cétonique
📊 Odor Threshold
Non déterminé.
🧪 Ph
Non déterminé.
🧊 Melting Point
-86,3 °C
Critical Property
💨 Boiling Point
79-80,5 °C
Critical Property
🔥 Flash Point
-9 °C
Critical Property
📊 Freezing Point
-86,3 °C
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non déterminé.
💨 Vapor Pressure
105 hPa
📊 Vapor Density
Non déterminé.
📊 Relative Density
Non déterminé.
📊 Bulk Density
Not available
⚖️ Density
0,804-0,807 g/cm³
Critical Property
🔥 Flammability
Non applicable.
📊 Upper Explosive Limit
11,5 Vol %
📊 Lower Explosive Limit
1,8 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
514 °C
📊 Decomposition Temperature
Non déterminé.
💧 Solubility
Not available
📊 Partition Coefficient
Non déterminé.
📊 Solubility In Water
290 g/l
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
0,4 mPas
📊 Kinematic Viscosity
Non déterminé.
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Veiller à une bonne aération du local, même au niveau du sol (les vapeurs sont plus lourdes que l'air).

🏪 Storage Conditions

• Stocker dans un endroit frais.

• Tenir les emballages hermétiquement fermés.

• Stocker au frais et au sec dans des fûts bien fermés.

🔥 Fire Prevention Measures

Tenir à l'abri des sources d'inflammation - ne pas fumer.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🧤 Hand Protection

Gants résistant aux solvants. Le matériau des gants doit être impermeable et résistant au produit / à la substance / à la préparation. Choix du matériau des gants en fonction des temps de pénétration, du taux de perméabilité et de la dégradation. Matériau des gants: Butylcaoutchouc. Épaisseur du matériau recommandée: > 0,7 mm. Temps de pénétration du matériau des gants: Pour le mélange des produits chimiques mentionnés ci-dessous, le temps de pénétration doit être d'au moins 120 minutes (perméabilité selon la norme EN 374 section 3: taux 4).

👁️ Eye Protection

Lunettes de protection hermétiques. Lunettes de protection recommandées pour le transvasement.

😷 Respiratory Protection

Utiliser un appareil de protection respiratoire si la ventilation est insuffisante. Filtre recommandé pour une utilisation momentanée: Filtre A

🦺 Skin/Body Protection

Vêtement de protection résistant aux solvants

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Pas de décomposition en cas d'usage conforme.

⚗️ Reactivity

Pas d'autres informations importantes disponibles.

⚠️ Hazardous Reactions

Aucune réaction dangereuse connue.

🚫 Conditions to Avoid

Pas d'autres informations importantes disponibles.

🧪 Incompatible Materials

Pas d'autres informations importantes disponibles.

💨 Hazardous Decomposition Products

Danger de formation de produits pyrolysés toxiques

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Evacuation conformément aux prescriptions légales.

🗂️ Product Disposal Recommendations

Ne doit pas être évacué avec les ordures ménagères.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1193

📦 Proper Shipping Name

ETHYL METHYL KETONE (METHYL ETHYL KETONE)

📋 Packing Group

II

🚛 ADR Transport Precautions

Attention: Liquides inflammables.

🚢 IMDG Maritime Transport Precautions

Attention: Liquides inflammables.

✈️ IATA Air Transport Precautions

Attention: Liquides inflammables.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is DYK CLEANER TI 1L*12 NLFR known by?

DYK CLEANER TI 1L*12 NLFR is also known as: Methyl ethyl ketone

What is the hazard signal word for DYK CLEANER TI 1L*12 NLFR?

The signal word for this substance is "danger".

What is the physical form of DYK CLEANER TI 1L*12 NLFR?

DYK CLEANER TI 1L*12 NLFR is a liquide appearing as incolore with incolore color. It has cétonique odor.

What is DYK CLEANER TI 1L*12 NLFR used for?

Nettoyant

What are the hazard statements for DYK CLEANER TI 1L*12 NLFR?

This substance has 3 hazard statements: H225: Liquide et vapeurs très inflammables. H319: Provoque une sévère irritation des yeux. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of DYK CLEANER TI 1L*12 NLFR?

The melting point is -86,3 °C and the boiling point is 79-80,5 °C.