Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Aquaplan - Roofix commonly used colle à froid pour etanchéités bitumineuses.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H226: Liquide et vapeurs inflammables.
Precautionary Statements
- P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
- P102: Tenir hors de portée des enfants.
- P103: Lire l'étiquette avant utilisation.
- P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
- P241: Utiliser du matériel électrique/de ventilation/d'éclairage antidéflagrant.
- P280: Porter des gants de protection / un équipement de protection des yeux / un équipement de protection du visage.
- P303+P361+P353: EN CAS DE CONTACT AVEC LA PEAU (ou les cheveux): Enlever immédiatement tous les vêtements contaminés. Rincer la peau à l'eau/Se doucher.
- P403+P235: Stocker dans un endroit bien ventilé. Tenir au frais.
- P501: Éliminer le contenu/récipient conformément à la réglementation locale/régionale/nationale/internationale.
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
IKO nv - Aquaplan
manufacturer
d'Herbouvillekaai 80, B-2020 Antwerpen, Belgium
BE
+32 (0)3 248 30 00
+32 (0)3 248 37 77
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Antigif Centrum België/Centre Antipoisons
+32 (0)70 245245
BE
Centre Antipoisons France
+33 (3) 883 737 37
FR
Schweizerische Toxikologisches Informationszentrum
+41 (1) 251 51 51
CH
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mélange des substances mentionnées à la suite avec des additifs non dangereux.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrocarbons,C9-C11, n-alkanes, isoalkanes cyclic, <2% aromates EC: 919-857-5 | N/A | 10-25% | Hazardous |
| talloil fatty acid EC: 272-756-1 | 68910-93-0 | 0.5-1% | Hazardous |
Additional Information
Pour le libellé des phrases de risque citées, se référer au chapitre 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Donner de l'air frais, consulter un médecin en cas de troubles.
Eye Contact
Rincer les yeux, sous l'eau courante, pendant plusieurs minutes, en écartant bien les paupières.
Ingestion/Swallowing
Si les troubles persistent, consulter un médecin.
Medical Treatment
Pas d'autres informations importantes disponibles.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Sans autre indication, voir point 7.
Hand Protection
Gants resistant aux solvants. Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.
Eye Protection
Lunettes de protection hermétiques
Respiratory Protection
N'est pas nécessaire si la pièce dispose d'une bonne ventilation.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
UN1268
Proper Shipping Name
PRODUITS PÉTROLIERS, N.S.A.
Transport Hazard Class
3
Packing Group
III
ADR Transport Precautions
Attention: Liquides inflammables.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Aquaplan - Roofix?
The signal word for this substance is "warning".
What is the physical form of Aquaplan - Roofix?
Aquaplan - Roofix is a visqueuse with noir color. It has de type solvanté odor.
What is the solubility of Aquaplan - Roofix?
Insoluble dans l'eau; Miscible avec de nombreux solvants organiques
What is Aquaplan - Roofix used for?
Colle à froid pour etanchéités bitumineuses
What are the hazard statements for Aquaplan - Roofix?
This substance has 1 hazard statements: H226: Liquide et vapeurs inflammables.
What is the melting point of Aquaplan - Roofix?
The melting point is Non déterminé. and the boiling point is 130 ℃.