NextSDS Logo
Aq

Aquaplan - Roofix

WARNING Visqueuse SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aquaplan - Roofix

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Colle à froid pour etanchéités bitumineuses
Uses Advised Against
Pas d'autres informations importantes disponibles.

Overview

Aquaplan - Roofix commonly used colle à froid pour etanchéités bitumineuses.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Liquide et vapeurs inflammables.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P103: Lire l'étiquette avant utilisation.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P241: Utiliser du matériel électrique/de ventilation/d'éclairage antidéflagrant.
  • P280: Porter des gants de protection / un équipement de protection des yeux / un équipement de protection du visage.
  • P303+P361+P353: EN CAS DE CONTACT AVEC LA PEAU (ou les cheveux): Enlever immédiatement tous les vêtements contaminés. Rincer la peau à l'eau/Se doucher.
  • P403+P235: Stocker dans un endroit bien ventilé. Tenir au frais.
  • P501: Éliminer le contenu/récipient conformément à la réglementation locale/régionale/nationale/internationale.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

IKO nv - Aquaplan

manufacturer

📍

d'Herbouvillekaai 80, B-2020 Antwerpen, Belgium

🌍

BE

📞

+32 (0)3 248 30 00

📠

+32 (0)3 248 37 77

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigif Centrum België/Centre Antipoisons

📞

+32 (0)70 245245

🌍

BE

Centre Antipoisons France

📞

+33 (3) 883 737 37

🌍

FR

Schweizerische Toxikologisches Informationszentrum

📞

+41 (1) 251 51 51

🌍

CH

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mélange des substances mentionnées à la suite avec des additifs non dangereux.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
hydrocarbons,C9-C11, n-alkanes, isoalkanes cyclic, <2% aromates
EC: 919-857-5
N/A 10-25% ⚠️ Hazardous
talloil fatty acid
EC: 272-756-1
68910-93-0 0.5-1% ⚠️ Hazardous

Additional Information

Pour le libellé des phrases de risque citées, se référer au chapitre 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Donner de l'air frais, consulter un médecin en cas de troubles.

👁️ Eye Contact

Rincer les yeux, sous l'eau courante, pendant plusieurs minutes, en écartant bien les paupières.

🍽️ Ingestion/Swallowing

Si les troubles persistent, consulter un médecin.

Medical Treatment

Pas d'autres informations importantes disponibles.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Visqueuse
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Noir
📊 Colour Intensity
Not available
📊 Form
Visqueuse
👃 Odor
De type solvanté
📊 Odor Threshold
Non déterminé.
🧪 Ph
Non déterminé.
🧊 Melting Point
Non déterminé.
Critical Property
💨 Boiling Point
130 ℃
Critical Property
🔥 Flash Point
36 ℃
Critical Property
📊 Freezing Point
Non déterminé.
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non déterminé.
💨 Vapor Pressure
2 hPa
📊 Vapor Density
Non déterminé.
📊 Relative Density
Non déterminé.
📊 Bulk Density
Not available
⚖️ Density
1,15 g/cm3
Critical Property
🔥 Flammability
Non applicable.
📊 Upper Explosive Limit
7,0 Vol %
📊 Lower Explosive Limit
0,5 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Le produit ne s'enflamme pas spontanément.
📊 Decomposition Temperature
Non déterminé.
💧 Solubility
Insoluble dans l'eau; Miscible avec de nombreux solvants organiques
📊 Partition Coefficient
Non déterminé.
📊 Solubility In Water
Insoluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
220 g/L
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
40000 mPas
📊 Kinematic Viscosity
Non déterminé.
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Gants resistant aux solvants. Le choix de gants appropriés dépend non seulement du matériau, mais aussi d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Puisque le produit représente une préparation composée de plusieurs substances, la résistance des matériaux des gants ne peut pas être calculée à l'avance et doit, alors, être contrôlée avant l'utilisation. Le temps de pénétration exact est à déterminer par le fabricant des gants de protection et à respecter.

👁️ Eye Protection

Lunettes de protection hermétiques

😷 Respiratory Protection

N'est pas nécessaire si la pièce dispose d'une bonne ventilation.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1268

📦 Proper Shipping Name

PRODUITS PÉTROLIERS, N.S.A.

⚠️ Transport Hazard Class

3

📋 Packing Group

III

🚛 ADR Transport Precautions

Attention: Liquides inflammables.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aquaplan - Roofix?

The signal word for this substance is "warning".

What is the physical form of Aquaplan - Roofix?

Aquaplan - Roofix is a visqueuse with noir color. It has de type solvanté odor.

What is the solubility of Aquaplan - Roofix?

Insoluble dans l'eau; Miscible avec de nombreux solvants organiques

What is Aquaplan - Roofix used for?

Colle à froid pour etanchéités bitumineuses

What are the hazard statements for Aquaplan - Roofix?

This substance has 1 hazard statements: H226: Liquide et vapeurs inflammables.

What is the melting point of Aquaplan - Roofix?

The melting point is Non déterminé. and the boiling point is 130 ℃.