NextSDS Logo
Aq

Aquaplan - Anti-Condensation

Visqueuse SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aquaplan - Anti-Condensation

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Matériel d'étanchéité acrylique
Uses Advised Against
Pas d'autres informations importantes disponibles.

Overview

Aquaplan - Anti-Condensation commonly used matériel d'étanchéité acrylique.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • Tenir hors de portée des enfants.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

IKO nv - Aquaplan

manufacturer

📍

d'Herbouvillekaai 80, B-2020 Antwerpen, Belgium

🌍

BE

📞

+32 (0)3 248 30 00

📠

+32 (0)3 248 37 77

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigif Centrum België/Centre Antipoisons

📞

+32 (0)70 245245

🌍

BE

Centre Antipoisons Paris

📞

+33 (0)1 40 05 48 48

🌍

FR

FR - ORFILA (INRS)

📞

+33 (0)1 45 42 59 59

🌍

FR

Schweizerische Toxikologisches Informationszentrum

📞

+41 (1) 251 51 51

🌍

CH

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mélange des substances mentionnées à la suite avec des additifs non dangereux.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
naphta lourd (pétrole), hydrodésulfuré
EC: 265-185-4
64742-82-1 2.5-5% ⚠️ Hazardous
naphta lourd (pétrole), hydrotraité
EC: 265-150-3
64742-48-9 2.5% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Donner de l'air frais en abondance et consulter un médecin pour plus de sécurité. En cas d'inconscience, coucher et transporter la personne en position latérale stable.

Symptoms:

En cas de malaise.

🖐️ Skin Contact

Laver immédiatement à l'eau et au savon et bien rincer.

Symptoms:

Irritation persistante de la peau.

👁️ Eye Contact

Rincer les yeux, sous l'eau courante, pendant plusieurs minutes, en écartant bien les paupières.

Symptoms:

Irritation persistante des yeux.

🍽️ Ingestion/Swallowing

Envoyer immédiatement chercher un médecin.

Medical Treatment

Pas d'autres informations importantes disponibles.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

CO2, poudre d'extinction ou eau pulvérisée. Combattre les foyers importants avec de l'eau pulvérisée ou de la mousse résistant à l'alcool.

⚠️ Specific Fire Hazards

Possibilité de formation de gaz toxiques en cas d'échauffement ou d'incendie. Peut être dégagé en cas d'incendie: Oxyde d'azote (NOx)

🛡️ Firefighter Protection Equipment

Aucune mesure particulière n'est requise.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🌍 Environmental Precautions

Ne pas rejeter à l'égout, ni dans le milieu naturel. En cas de pénétration dans les eaux ou les égouts, avertir les autorités compétentes. Ne pas rejeter dans les canalisations, dans les eaux de surface et dans les nappes d'eau souterraines.

🧹 Cleanup Methods

Eau chaude additionnée de produit nettoyant

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Visqueuse
Critical Property
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Blanc
📊 Colour Intensity
Not available
📊 Form
Visqueuse
👃 Odor
Caractéristique
📊 Odor Threshold
Not available
🧪 Ph
Non déterminé.
🧊 Melting Point
Not available
💨 Boiling Point
Non déterminé.
Critical Property
🔥 Flash Point
Non applicable.
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
💨 Vapor Pressure
Non déterminé.
📊 Vapor Density
Not available
📊 Relative Density
>1
📊 Bulk Density
Not available
⚖️ Density
>1
Critical Property
🔥 Flammability
Le produit ne s'enflamme pas spontanément.
📊 Upper Explosive Limit
Not available
📊 Lower Explosive Limit
Not available
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Le produit ne s'enflamme pas spontanément.
📊 Decomposition Temperature
Not available
💧 Solubility
Insoluble
📊 Partition Coefficient
Not available
📊 Solubility In Water
Insoluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
5 g/l
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Aucune mesure particulière n'est requise.

• Veiller à une bonne ventilation/aspiration du poste de travail.

• Eviter la formation d'aérosols.

🏪 Storage Conditions

• Ne conserver que dans le fût d'origine.

🔥 Fire Prevention Measures

Aucune mesure particulière n'est requise.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Sans autre indication, voir point 7.

🧤 Hand Protection

Gants de protection en caoutchouc nitrile, caoutchouc naturel (Latex), ou PVC. Le choix dépend du matériau et d'autres critères de qualité variables selon le fabricant. La résistance des matériaux des gants doit être contrôlée avant utilisation. Le temps de pénétration exact est à déterminer par le fabricant des gants et à respecter.

👁️ Eye Protection

Lunettes de protection recommandées pour le transvasement.

😷 Respiratory Protection

En cas d'exposition faible ou de courte durée, utiliser un filtre respiratoire; en cas d'exposition intense ou durable, utiliser un appareil de respiration indépendant de l'air ambiant.

🦺 Skin/Body Protection

Vêtements de travail protecteurs

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Pas de décomposition en cas d'usage conforme.

⚗️ Reactivity

Pas d'autres informations importantes disponibles.

⚠️ Hazardous Reactions

Aucune réaction dangereuse connue.

🚫 Conditions to Avoid

Eviter le gel.

🧪 Incompatible Materials

Pas d'autres informations importantes disponibles.

💨 Hazardous Decomposition Products

Oxydes nitriques (NOx)

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Toxicité

Toxicité aquatique: Pas d'autres informations importantes disponibles.

🌱 Persistance et degradabilité

Pas d'autres informations importantes disponibles.

🌱 Potentiel de bioaccumulation

Pas d'autres informations importantes disponibles.

🌱 Mobilité dans le sol

Pas d'autres informations importantes disponibles.

🌱 Résultats des évaluations PBT et VPVB

PBT: Non applicable. vPvB: Non applicable.

🌱 Autres effets néfastes

Pas d'autres informations importantes disponibles.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

L'élimination doit être conforme aux lois et réglementations régionales, nationales et locales applicables.

🗂️ Product Disposal Recommendations

De petites quantités peuvent être mises en décharge avec les ordures ménagères.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

📋 Regulatory Summary

Aucun des composants n'est compris.

Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

ℹ️ Additional Regulatory Information

Ce produit ne contient pas des SVHC.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the physical form of Aquaplan - Anti-Condensation?

Aquaplan - Anti-Condensation is a visqueuse with blanc color. It has caractéristique odor.

What is the solubility of Aquaplan - Anti-Condensation?

Insoluble

What is Aquaplan - Anti-Condensation used for?

Matériel d'étanchéité acrylique