NextSDS Logo
AR

ARBOCEL B xx

NO SIGNAL WORD Poudre SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ARBOCEL B xx
Chemical Name
cellulose

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Le produit est destin aux utilisateurs professionnels.
Uses Advised Against
non pertinent

Overview

ARBOCEL B xx (CAS: 9004-34-6 ) is a poudre substance commonly used le produit est destin aux utilisateurs professionnels..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

J.RETTENMAIER & SHNE GMBH + CO KG company logo - Safety Data Sheet supplier organization

J.RETTENMAIER & SHNE GMBH + CO KG

manufacturer

πŸ“

Holzmhle 1 D 73494 Rosenberg Allemagne

🌍

DE

πŸ“ž

+49 7967 152 0

πŸ“ 

+49 7967 152 222

🌐 www.jrs.de

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+49 7967 152 199

🌍

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
cellulose
EC: 232-674-9
9004-34-6 Not specified βœ“ Non-hazardous

Additional Information

Selon REACH, la substance ne ncessite pas d'enregistrement.

Composition Notes

non pertinent (Texte des phrases H- et EUH: voir paragraphe 16.)

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Veiller Γ  un apport d'air frais.

πŸ‘οΈ Eye Contact

Rincer soigneusement et abondamment avec une douche oculaire ou de l'eau.

🚨 Immediate Medical Attention Required

En cas de doute ou s'il y a des symptΓ΄mes, demander un conseil mΓ©dical. En cas d'irritation oculaire, consulter un ophtalmologue.

Medical Treatment

Traitement symptomatique.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Solubility In Fat
insoluble
πŸ“Š Lower Explosive Limit
30 g/m
πŸ‘οΈ Appearance
Poudre
🧊 Melting Point
non applicable
Critical Property
πŸ‘ƒ Odor
inodore
πŸ“Š Solubility In Water
insoluble
πŸ“Š Softening Point
Not available
πŸ“Š State Under Standard Conditions
Not available
πŸ”₯ Flammability
non pertinent
πŸ’¨ Vapor Pressure
non applicable
πŸ“Š Bulk Density
20 - 330 g/L
πŸ“Š Explosive Limits
Not available
πŸ“Š Dynamic Viscosity
non applicable
πŸ“Š Kinematic Viscosity
non applicable
πŸ“Š Physical State Data
solid
🎨 Colour
blanc
πŸ’¨ Boiling Point
non applicable
Critical Property
πŸ“Š Vapor Density
non applicable
πŸ“Š Crystallisation Point
Not available
πŸ“Š Odor Threshold
non pertinent
πŸ“Š Partition Coefficient
non applicable
πŸ“Š Properties Status
Not available
πŸ’¨ Evaporation Rate
non applicable
πŸ“Š Voc Content
Not available
πŸ§ͺ Ph
5 - 8
πŸ“Š Colour Intensity
Not available
πŸ“Š Auto Ignition Temperature
non dΓ©terminΓ©
πŸ“Š Molecular Weight
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Relative Density
Not available
πŸ“Š Decomposition Temperature
~ 200 C
πŸ“Š Form
Poudre
πŸ“Š Metal Corrosion
Not available
πŸ’§ Solubility
non pertinent
πŸ“Š Freezing Point
non applicable
πŸ“Š Cloud Point
Not available
πŸ§ͺ Physical State
Poudre
Critical Property
πŸ“Š Upper Explosive Limit
11 000 g/m
πŸ”₯ Flash Point
non dΓ©terminΓ©
Critical Property
βš–οΈ Density
~ 1,5 g/cm
Critical Property

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

mesures techniques d'aspiration ou de ventilation

🧀 Hand Protection

Il n'est pas ncessaire de se protger les mains

πŸ‘οΈ Eye Protection

Lunettes de protection contre la poussire.

😷 Respiratory Protection

Appareil de protection respiratoire appropri : Demi-masque filtrant (DIN EN 149) Demi-masque ou quart de masque: concentration maximale pour substances avec des valeurs limites: filtre P1 jusqu max. 4 fois la VLE; filtre P2 jusqu max. 10 fois la VLE; filtre P3 jusqu max. 30 fois la VLE. La classe des filtres de protection respiratoire doit absolument tre adapte la concentration max. du polluant (gaz/vapeur/arosol/particules) pouvant tre produit. En cas de dpassement, il faut utiliser des appareils indpendants!

🦺 Skin/Body Protection

non indispensable.

🌍 Environmental Exposure Controls

Voir chapitre 7. D'autres mesures complmentaires ne sont pas ncessaires.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ARBOCEL B xx?

The signal word for this substance is "no signal word".

What is the physical form of ARBOCEL B xx?

ARBOCEL B xx is a poudre appearing as poudre with blanc color. It has inodore odor.

What is the solubility of ARBOCEL B xx?

non pertinent

What is ARBOCEL B xx used for?

Le produit est destin aux utilisateurs professionnels.

What is the melting point of ARBOCEL B xx?

The melting point is non applicable and the boiling point is non applicable.