NextSDS Logo
LO

LOCTITE 577 ACC 50ML EGFD

WARNING liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LOCTITE 577 ACC 50ML EGFD

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Colle

Overview

LOCTITE 577 ACC 50ML EGFD is a liquide hautement visqueux substance commonly used colle.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Skin Irr. Category 2 H315
Eye Irrit. Category 2 H319
Skin Sens. Category 1 H317
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Provoque une irritation cutane.
  • H317: Peut provoquer une allergie cutane.
  • H319: Provoque une svre irritation des yeux.
  • H335: Peut irriter les voies respiratoires.

Precautionary Statements

  • P101: En cas de consultation dun mdecin, garder disposition le rcipient ou ltiquette.
  • P102: Tenir hors de porte des enfants.
  • P501: liminer le contenu/rcipient conformment la rglementation nationale.
  • P261: viter de respirer les vapeurs.
  • P280: Porter des gants de protection.
  • P302+P352: EN CAS DE CONTACT AVEC LA PEAU: laver abondamment leau et au savon.
  • P333+P313: En cas dirritation ou d'ruption cutane: consulter un mdecin.
  • P337+P313: Si lirritation oculaire persiste: consulter un mdecin.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Belgium N.V.

national supplier

๐Ÿ“

Esplanade 1 1020 Brussels

๐ŸŒ

BE

๐Ÿ“ž

+32 (2) 421 2711

๐Ÿ“ 

+32 (2) 420 7025

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32 70 222 076

๐ŸŒ

BE

๐Ÿ•’

24 h

Centre Antipoisons

๐Ÿ“ž

+32 (0) 70 245245

๐ŸŒ

BE

๐Ÿ•’

7j/7j 24h-24h

Centre Antipoisons

๐Ÿ“ž

++352 8002 5500

๐ŸŒ

LU

๐Ÿ•’

7j/7j 24h24h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Adhsif anarobie

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dimthacrylate de ttramthylne
EC: 218-218-1
2082-81-7 10-20% โš ๏ธ Hazardous
Dimthacrylate de 2,2'-thylenedioxydithyle
EC: 203-652-6
109-16-0 5-10% โš ๏ธ Hazardous
1-Actyl-2-phnylhydrazine
EC: 204-055-3
114-83-0 0.1-1% โš ๏ธ Hazardous
Hydroperoxyde de cumne
EC: 201-254-7
80-15-9 0.1-1% โš ๏ธ Hazardous
Acide malique
EC: 203-742-5
110-16-7 0.1-1% โš ๏ธ Hazardous
N,N'-ethane-1,2-diylbis(12-hydroxyoctadecane-1-amide)
EC: 204-613-6
123-26-2 0.1-1% โš ๏ธ Hazardous
4,4-Diisocyanate de diphnylmthane
EC: 202-966-0
101-68-8 0.01-0.1% โš ๏ธ Hazardous
Menadione
EC: 200-372-6
58-27-5 0.01-0.025% โš ๏ธ Hazardous

Composition Notes

Dclaration des ingrdients conformment au rglement CLP (CE) n 1272/2008. Voir texte complet des phrases H et autres abrviations dans paragraphe 16 "Autres informations". Les substances non classifies peuvent avoir une valeur limite d'exposition sur le lieu de tavail.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air; if discomfort persists, consult a doctor.

Symptoms:

Irritation, cough, respiratory insufficiency, chest tightness.

๐Ÿ–๏ธ Skin Contact

Rinse with running water and soap. If irritation persists, consult a doctor.

Symptoms:

Rash, hives, redness, inflammation.

๐Ÿ‘๏ธ Eye Contact

Immediately rinse with running water (for 10 minutes), consult a doctor.

Symptoms:

Irritation, conjunctivitis.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse inside of mouth, drink 1-2 glasses of water, do NOT induce vomiting, consult a doctor.

๐Ÿšจ Immediate Medical Attention Required

Consult a doctor if symptoms persist or after initial first aid measures.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquide
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquide hautement visqueux
๐ŸŽจ Colour
jaune
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Doux
๐Ÿ“Š Odor Threshold
Il n'y a pas de donnes / Non applicable
๐Ÿงช Ph
Non disponible
๐ŸงŠ Melting Point
Il n'y a pas de donnes / Non applicable
Critical Property
๐Ÿ’จ Boiling Point
- 149 C (> 300.2 F)
Critical Property
๐Ÿ”ฅ Flash Point
- 93 C (> 199.4 F); pas de mthode
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Il n'y a pas de donnes / Non applicable
๐Ÿ’จ Vapor Pressure
< 300 mbar
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Il n'y a pas de donnes / Non applicable
โš–๏ธ Density
1,15 - 1,2 g/cm3 (20 C (68 F))
Critical Property
๐Ÿ”ฅ Flammability
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Upper Explosive Limit
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Lower Explosive Limit
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Decomposition Temperature
Il n'y a pas de donnes / Non applicable
๐Ÿ’ง Solubility
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Partition Coefficient
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Solubility In Water
Soluble (Solv.: Eau)
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
70.000,00 - 130.000,00 mpa.s (Brookfield; Appareil: RVT; 25 C (77 F); frq. rot.: 2,5 min-1; Broche N: 6)
๐Ÿ“Š Kinematic Viscosity
Il n'y a pas de donnes / Non applicable
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Veiller une bonne ventilation/aspiration.

๐Ÿงค Hand Protection

Gants de protection rsistant aux produits chimiques (EN 374) Matires appropries un contact de courte dure ou des projections (recommandation: indice de protection au moins 2, soit > 30 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Matires appropries galement un contact direct et plus long (recommandation: indice de protection 6, soit > 480 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Les indications faites sont bases sur la littrature et sur les informations fournies par les fabricants de gants ou sont dduites par analogie de matires similaires. Il faut tenir compte que la dure d'utilisation d'un gant de protection contre les produits chimiques dans la pratique peut tre sensiblement plus courte que le temps de permation dtermin selon EN 374 en raison de multiples facteurs d'influence (comme la temprature p. ex.). Le gant doit tre remplac s'il prsente des signes d'usure.

๐Ÿ‘๏ธ Eye Protection

Des lunettes de scurit avec protections latrales ou des lunettes descurit pour produits chimiques devraient tre portes s'il y un riqued'claboussures. Lquipement de protection pour les yeux doit tre conforme la norme EN166.

๐Ÿ˜ท Respiratory Protection

Assurer une aration et une ventilation suffisantes. Il convient de porter un masque agr ou un respirateur avec unecartouche de vapeur organique si le produit est utilis dans un endroitmal ventil. Type de filtre: A (EN 14387)

๐Ÿฆบ Skin/Body Protection

Porter un vtement de protection appropri. Les vtements de protection doivent tre conformes la norme EN14605 en cas dclaboussures de liquide, et la norme EN13982 en cas dexposition aux poussires.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LOCTITE 577 ACC 50ML EGFD?

The signal word for this substance is "warning".

What is the physical form of LOCTITE 577 ACC 50ML EGFD?

LOCTITE 577 ACC 50ML EGFD is a liquide appearing as liquide hautement visqueux with jaune color. It has doux odor.

What is the solubility of LOCTITE 577 ACC 50ML EGFD?

Il n'y a pas de donnes / Non applicable

What is LOCTITE 577 ACC 50ML EGFD used for?

Colle

What are the hazard statements for LOCTITE 577 ACC 50ML EGFD?

This substance has 4 hazard statements: H315: Provoque une irritation cutane. H317: Peut provoquer une allergie cutane. H319: Provoque une svre irritation des yeux. H335: Peut irriter les voies respiratoires.

What is the melting point of LOCTITE 577 ACC 50ML EGFD?

The melting point is Il n'y a pas de donnes / Non applicable and the boiling point is - 149 C (> 300.2 F).